Old 05-21-2007
SCO Openserver 6.0 Insall on HP DL380 serverl

Trying to install Openserver 6.0 on this server which has an integrated Smart Array P400.

Install halts with the message .......

"Incorrect Disk Partitioning .........................."

I havent yet got to the "divvy" and disk partitioning section of the install section so I am guessing that SCO doesnt recognise the Smart Array at all - Can anyone help please?
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Help For SCO OpenServer

I've just installed Unix SCO OpenServer System v in an Intel PC and Everithing ok, except just one thing, in the begining of the installation the wizard asked me about the mouse , i have a generic 3 buttons mouse and i took a logitech and did not work i need to change the mouse configuration, ... (2 Replies)
Discussion started by: jimmyvaldes
2 Replies

2. UNIX for Dummies Questions & Answers

sco openserver 5.5

hello! when i try to make my system dual boot with both win98 & sco open server 5.5 it doesn't work at all.neither win98 take start nor sco open server boots.what should i do ? kindly help me thanks (1 Reply)
Discussion started by: buntty
1 Replies

3. UNIX for Advanced & Expert Users

SCO 5.0.2 openserver

I am doing some work for a customer that is running SCO 5.0.2 openserver and they have lost their cd. Is there anyplace I can download it? I have a replacement being shipped but it will not be here for two days and they are down. Any ideals? (3 Replies)
Discussion started by: SCOoT
3 Replies

4. UNIX for Dummies Questions & Answers

SCO Openserver 6.0

Hi there guys. I just got this new SCO version and i'm having some problem printing from shell, This is what i'm typing at the # sign : lp -dHP /etc/hosts and it prints no problem but when i use any other user at the $ sign it gives me this error. /dev/fd/7: /usr/lib/lp/sysv/7: not found. ... (1 Reply)
Discussion started by: josramon
1 Replies

5. UNIX for Dummies Questions & Answers

SCO Openserver 6.0

Hi guys, I just got this new 6.0 version and i'm trying to setup a remote office to telnet to this server running sco 6.0, in previous version all i have to do is add this file under /etc/rc2.d call S99route and put the gate in that file and that was it, for some reason in 6.0 it does not... (1 Reply)
Discussion started by: josramon
1 Replies

6. SCO

sco openserver 5.0.7

Dear members when i installed dual processor patch in openserver 5.0.7 in hp ML370 G4 server it hangs in sco at G_hd_config. i tried MP4, EFS 5.64,5.70A but not solved the problem.. (0 Replies)
Discussion started by: M_farooqui
0 Replies

7. SCO

I need SCO Openserver 4.2!!!!

I need SCO Openserver 4.2. Please, give me distributive of that version SCO:eek: (0 Replies)
Discussion started by: caine
0 Replies

8. UNIX for Dummies Questions & Answers

Printer for SCO OpenServer 5

I only know enough about Unix to get me in trouble: I have an old UNIX SCO OpenServer 5 that I am phasing out. It had been connected to an HP laserjet via a serial port connection. As part of the phase out I disconnected and removed the workstations leaving only the server. I didn't think I... (9 Replies)
Discussion started by: rpmaps
9 Replies

9. SCO

Installation on SCO Openserver 5.0.5

Hello all, First off- great forum! I have learned a lot just by reading some of the questions and answers. Good to see there are good people out there still willing to help! Here is my dilemma- I have a fairly new server running an Activant product on it, which runs SCO openserver 5.0.5... (9 Replies)
Discussion started by: crt001
9 Replies

10. SCO

SCO 5.0.7 driver for HP SmartArray P410i Controller on Proliant DL380 G7?

Hi I hope this is the right forum. I am attempting to install SCO 5.0.7 on a Proliant DL380 G7 with a Smart Array P410I Controller. I need a driver for this. Can anybody point me to a download? Thanks in anticipation. (12 Replies)
Discussion started by: Stuart1946
12 Replies
HPSA(4) 						     Linux Programmer's Manual							   HPSA(4)

NAME
hpsa - HP Smart Array SCSI driver SYNOPSIS
modprobe hpsa [ hpsa_allow_any=1 ] DESCRIPTION
hpsa is a SCSI driver for HP Smart Array RAID controllers. Options hpsa_allow_any=1: This option allows the driver to attempt to operate on any HP Smart Array hardware RAID controller, even if it is not explicitly known to the driver. This allows newer hardware to work with older drivers. Typically this is used to allow installation of operating systems from media that predates the RAID controller, though it may also be used to enable hpsa to drive older controllers that would normally be handled by the cciss(4) driver. These older boards have not been tested and are not supported with hpsa, and cciss(4) should still be used for these. Supported hardware The hpsa driver supports the following Smart Array boards: Smart Array P700M Smart Array P212 Smart Array P410 Smart Array P410i Smart Array P411 Smart Array P812 Smart Array P712m Smart Array P711m StorageWorks P1210m Since Linux 4.14, the following Smart Array boards are also supported: Smart Array 5300 Smart Array 5312 Smart Array 532 Smart Array 5i Smart Array 6400 Smart Array 6400 EM Smart Array 641 Smart Array 642 Smart Array 6i Smart Array E200 Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E500 Smart Array P400 Smart Array P400i Smart Array P600 Smart Array P700m Smart Array P800 Configuration details To configure HP Smart Array controllers, use the HP Array Configuration Utility (either hpacuxe(8) or hpacucli(8)) or the Offline ROM-based Configuration Utility (ORCA) run from the Smart Array's option ROM at boot time. FILES
Device nodes Logical drives are accessed via the SCSI disk driver (sd(4)), tape drives via the SCSI tape driver (st(4)), and the RAID controller via the SCSI generic driver (sg(4)), with device nodes named /dev/sd*, /dev/st*, and /dev/sg*, respectively. HPSA-specific host attribute files in /sys /sys/class/scsi_host/host*/rescan This is a write-only attribute. Writing to this attribute will cause the driver to scan for new, changed, or removed devices (e.g., hot-plugged tape drives, or newly configured or deleted logical drives, etc.) and notify the SCSI midlayer of any changes detected. Normally a rescan is triggered automatically by HP's Array Configuration Utility (either the GUI or the command-line variety); thus, for logical drive changes, the user should not normally have to use this attribute. This attribute may be useful when hot plugging devices like tape drives, or entire storage boxes containing preconfigured logical drives. /sys/class/scsi_host/host*/firmware_revision This attribute contains the firmware version of the Smart Array. For example: # cd /sys/class/scsi_host/host4 # cat firmware_revision 7.14 HPSA-specific disk attribute files in /sys /sys/class/scsi_disk/c:b:t:l/device/unique_id This attribute contains a 32 hex-digit unique ID for each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat unique_id 600508B1001044395355323037570F77 /sys/class/scsi_disk/c:b:t:l/device/raid_level This attribute contains the RAID level of each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat raid_level RAID 0 /sys/class/scsi_disk/c:b:t:l/device/lunid This attribute contains the 16 hex-digit (8 byte) LUN ID by which a logical drive or physical device can be addressed. c:b:t:l are the controller, bus, target, and lun of the device. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat lunid 0x0000004000000000 Supported ioctl() operations For compatibility with applications written for the cciss(4) driver, many, but not all of the ioctls supported by the cciss(4) driver are also supported by the hpsa driver. The data structures used by these ioctls are described in the Linux kernel source file include/linux/cciss_ioctl.h. CCISS_DEREGDISK, CCISS_REGNEWDISK, CCISS_REGNEWD These three ioctls all do exactly the same thing, which is to cause the driver to rescan for new devices. This does exactly the same thing as writing to the hpsa-specific host "rescan" attribute. CCISS_GETPCIINFO Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID). CCISS_GETDRIVVER Returns driver version in three bytes encoded as: (major_version << 16) | (minor_version << 8) | (subminor_version) CCISS_PASSTHRU, CCISS_BIG_PASSTHRU Allows "BMIC" and "CISS" commands to be passed through to the Smart Array. These are used extensively by the HP Array Configuration Utility, SNMP storage agents, and so on. See cciss_vol_status at <http://cciss.sf.net> for some examples. SEE ALSO
cciss(4), sd(4), st(4), cciss_vol_status(8), hpacucli(8), hpacuxe(8), <http://cciss.sf.net>, and Documentation/scsi/hpsa.txt and Documentation/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source tree COLOPHON
This page is part of release 4.15 of the Linux man-pages project. A description of the project, information about reporting bugs, and the latest version of this page, can be found at https://www.kernel.org/doc/man-pages/. Linux 2017-09-15 HPSA(4)
All times are GMT -4. The time now is 11:09 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy