gonzotonka, your experience of seeing the bootup messages when you reconnected your terminal is odd. Normally, the characters are sent down the connecter. If a terminal is present, they are displayed, and if no terminal is there, they just disappear. It sounds like your console port is somehow using hardware flow control so it needs CTS or DTR raised before it will transmit. If this is the case you might have a problem. Run "yes|nl" on the console. Unplug the console for an hour and see if it hangs or continues running.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Console

Hi everybody, I have a Solaris 220 Entrprise SunMicrosystems UNIX box. I would like to know if my availability to connect a monitor, keyboard and mouse is limited? Can I connect whatever 'make' or it has to be a Sun one ?? Thanks very much (4 Replies)
Discussion started by: guest100
4 Replies

2. UNIX for Dummies Questions & Answers

console

Hi all, I have to disconnect the console of a live system which runs sunSolaris 2.7 Do I have to do a "kbd -a" before ?? The keyboard is connected to the monitor and the monitor is plugged in to the live system. Is the above command going to work OK?? Does anyone came across that b4... (5 Replies)
Discussion started by: guest100
5 Replies

3. UNIX for Advanced & Expert Users

/console

hi ! sorry for the stupid question but my /console is full and i need to clean it how do i clean it ? :confused: (2 Replies)
Discussion started by: karine
2 Replies

4. AIX

How to get console

Hi Guys, Please let me know how to get console for a pSeries 610 machine. It doesn't have a display card attached...Tried to user serial ports on that...not getting anything...but system is booting..displaying messages on the display pannel present in the front. please help in this....what... (1 Reply)
Discussion started by: b_manu78
1 Replies

5. UNIX for Dummies Questions & Answers

Console

Hi all, Where we can run two same program on unix console at same time? (7 Replies)
Discussion started by: sonali
7 Replies

6. Solaris

console question

Hi, I have rebooted the server and didn't come up, but I have logged into the box using console with root password. How do I know what run level ? I checked using who -r , it shows as run level 3. Isn't it run level 1 ? (3 Replies)
Discussion started by: mokkan
3 Replies

7. UNIX for Advanced & Expert Users

console /dev/console get image

We are using software (Pegasys) which runs on SunOS 5.8 and reads images from a Philips nuclear camera. The software is designed to run from the console. I need to be able to capture the images it produces on the display. The caveat is that I cannot use the X Windows display because the X Server... (3 Replies)
Discussion started by: sreyes27
3 Replies

8. Shell Programming and Scripting

how to access console of a switch having rj45 on switch side to db 9 female on pc side console cable

hi, how to access console of a switch having rj45 on switch side to db 9 female on pc side console cable which needs to be connected to one console server having rj11 on its side and db 9 female on other end.i.e. on switch side,console cable has rj45 and db 9 pin female connector on other side of... (1 Reply)
Discussion started by: pankajd
1 Replies

9. UNIX for Dummies Questions & Answers

Windows to Linux remote console using VNC brings up blank console screen with only mouse pointer

:confused:Hi This was installed on the Linux box a few weeks back by a guy that no longer works for us. All worked fine until last week. Now when we connect its just a blank screen with no icons. I get a whole bunch of errors when starting the service too: Tue Feb 23 14:29:45 2010 ... (1 Reply)
Discussion started by: wbdevilliers
1 Replies

10. UNIX for Dummies Questions & Answers

IP Console Vs Serial console.

Hi Gurus, Can some one explain me the difference between a IP console and a serial console. (1 Reply)
Discussion started by: rama krishna
1 Replies
termiox(7)						 Miscellaneous Information Manual						termiox(7)

NAME
termiox - extended general terminal interface SYNOPSIS
fildes, request, arg) DESCRIPTION
The extended general terminal interface supplements the termio(7) general terminal interface by adding support for asynchronous hardware flow control and local implementations of additional asynchronous features. Some systems may not support all of these capabilities because of hardware or software limitations. Other systems may not permit certain functions to be disabled. In such cases, the appropriate bits are ignored. If the capabilities can be supported, the interface described here must be used. Hardware Flow Control Modes Hardware flow control supplements the termio and character flow control (see termio(7)). Character flow control occurs when one device controls the data transfer of another device by inserting control characters in the data stream between devices. Hardware flow control occurs when one device controls the data transfer of another device by using electrical control signals on wires (circuits) of the asyn- chronous interface. Character flow control and hardware flow control can be simultaneously set. In asynchronous, full duplex applications, the use of the Electronics Industries Association's EIA-232-D Request To Send (RTS) and Clear To Send (CTS) circuits is the preferred method of hardware flow control. The EIA-232-D standard specified only unidirectional hardware flow control where the Data Circuit-terminating Equipment or Data Communica- tions Equipment (DCE) indicates to the Data Terminal Equipment (DTE) to stop transmitting data. The termiox interface allows both unidi- rectional and bidirectional hardware flow control; when bidirectional flow control is enabled, either the DCE or DTE can indicate to each other to stop transmitting data across the interface. Clock Modes Isochronous flow control and clock mode communication are not supported. Terminal Parameters Parameters that control the behavior of devices providing the termiox interface are specified by the structure, defined in the header file. Several system calls (see ioctl(5)) that fetch or change these parameters use the structure which contains the following members: The field describes hardware flow control modes: Enable RTS hardware flow control on input. Enable CTS hardware flow control on input. The RTS and CTS circuits are involved in establishing CCITT modem connections. Since RTS and CTS circuits are used both by CCITT modem connections and by hardware flow control, CCITT modem and hardware flow control cannot be simultaneously enabled. Variations of different hardware flow control methods can be selected by setting the appropriate bits. For example, bidirectional RTS/CTS flow control is selected by setting both the and bits. Unidirectional CTS hardware flow control is selected by setting only the bit. If is set, the Request to Send (RTS) circuit (line) is raised, and if the asynchronous port needs to have its input stopped, it lowers the Request to Send (RTS) line. If the RTS line is lowered, it is assumed that the connected device will stop its output until RTS is raised. If is set, output occurs only if the Clear To Send (CTS) circuit (line) is raised by the connected device. If the CTS line is lowered by the connected device, output is suspended until CTS is raised. termiox Structure Related IOCTL Command The system calls that reference the structure have the form: Commands using this form are: The argument is a pointer to a structure. The current terminal parameters are fetched and stored into that structure. The argument is a pointer to a structure. The current terminal parameters are set from the values stored in that structure. The change is immedi- ate. Errors that can be returned include: The port does not support hardware flow control. The file descriptor for this port is configured for CCITT mode access. Hardware flow control is not allowed on CCITT mode devices. The argument is a pointer to a structure. The current terminal parameters are set from the values stored in that structure. The change occurs after all characters queued for output have been transmitted. This form should be used when changing parameters that affect output. Errors that can be returned include: The port does not support hardware flow control. The file descriptor for this port is configured for CCITT mode access. Hardware flow control is not allowed on CCITT mode devices. The argument is a pointer to a structure. The current terminal parameters are set from the values stored in that structure. The change occurs after all characters queued for output have been transmitted; all characters queued for input are discarded, then the change occurs. Errors that can be returned include: The port does not support hardware flow control. The file descriptor for this port is configured for CCITT mode access. Hardware flow control is not allowed on CCITT mode devices. AUTHOR
was developed by HP and AT&T. FILES
Files in or under SEE ALSO
ioctl(2), termio(7), modem(7). HP-PB Only termiox(7)