Morning,

I've installed a new p550 into a rack and connected it up to the HMC but the HMC cannot find it, I don't understand why it's not?

Has anyone else had this problem before?

Thanks
Kees
 

10 More Discussions You Might Find Interesting

1. AIX

Hmc

Well i am right now working on an IBM P550 risc server with an HMC connected.. The server has 2 logical partitions (Lpar). both lpar is having Aix 5.3 installed. Now I have a doubt.. is it possible to have Aix in one lpar and windows 2003 in another.. cheers Bala (4 Replies)
Discussion started by: balaji_prk
4 Replies

2. Programming

Connected or not connected !

Hello ! I've got a question . I really don't het this point. Let's supose that I have a client connected to a server. I want the server IMEDIATLY know if the client is diconnected . How can I realize this ? :mad: Amd I'm just curios about one thing. I have a server and multiple clients... (3 Replies)
Discussion started by: !_30
3 Replies

3. AIX

Hmc

Hello everybody, had a question. Iam having a p650 box here, System Model: IBM,7038-6M2 Machine Serial Number: 1078DCC managed system - 1 which has 2 lpars on it i added memory to the box(made sure that memory added was in proper quads and was verified by a CE) after i rebooted the box, the... (4 Replies)
Discussion started by: karthikosu
4 Replies

4. AIX

HMC and Unix Box not connected

Hi There, I'm new here and this is my first (of many ;) ) problems. I've got AIX 5.3 on our unix box and i'm trying to do a DLPAR memory change, but then I ok it I get an error telling me that there is no RMC connection. Does anyone have any ideas what could cause this? Thanks in advance. ... (3 Replies)
Discussion started by: KeesH
3 Replies

5. AIX

Find the feature code of the installed processor card on my p550

Guys Does anyone know how to find the feature code of the installed processor card on my p550? Through AIX or HMC. Basically I need to find the processor card type. Thanks in advance Bala (2 Replies)
Discussion started by: balaji_prk
2 Replies

6. IP Networking

Am I Connected?

Be Gentle folks, I am a baby OpenSuSe 11.2 user :-) In windows Vista, there is a world in the systray when you are Internet connected and not just local. I have searched all over for a .RPM for the Network Manager or another packeg in Suse that can show me the same thing or something close. ... (0 Replies)
Discussion started by: donmaxwelliii
0 Replies

7. AIX

P550 Unable to access Console

I have recently aquired the following machine: IBM,9113-550 Up until yesterday we could connect a dumb terminal to serial port 1 and get console login. However the dumb terminal died. We are now using a laptop with a null modem cable attached to serial port 1. This works perfectly for all of... (1 Reply)
Discussion started by: rsw7724
1 Replies

8. AIX

LSSVCEVENTS [HMC]

Hi all :) two question... 1) in which file the HMC events will be stored? i talking about the log of the HMC console (lssvcevent). 2) The HMC function "Backup Critical Data" store the backup also on remote server through SFTP? In the documentation i read only FTP and NFS. ... (1 Reply)
Discussion started by: Zio Bill
1 Replies

9. AIX

HMC 7.7.5 errors - just me ?

Maybe this is the wrong forum, but... after upgrading one of our HMCs from 7.3.5 to 7.7.5 we detected two problems: - older problem files ( /info/en_US/eclipse/plugins/p7eai/heapdump... , /opt/ccfw/data/vr ) are not deleted by chhmcfs - HMC-scheduled backups via ftp to our nim-server don't run... (2 Replies)
Discussion started by: AchmedLachned
2 Replies

10. AIX

P550 9133 IPL Issues

First IPL of used P550 in Home Lab displayed this on Control Panel: Line-1(01 M F), Line-2(HMC=0 T). Issue #1: Changed "01" to "02" and "M" to "N" on line-1, but IPL failed; no change on display panel. Set "M" back to "N" and exit function "2", but function "3" for IPL restart would not display. ... (5 Replies)
Discussion started by: luw3486
5 Replies
FENCE_AGENT(8)						      System Manager's Manual						    FENCE_AGENT(8)

NAME
fence_lpar - Fence agent for IBM LPAR DESCRIPTION
fence_lpar accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent. fence_lpar can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts. PARAMETERS
-o, --action=<action> Fencing Action (Default Value: reboot) -a, --ip=<ip> IP Address or Hostname This parameter is always required. -l, --username=<name> Login Name This parameter is always required. -p, --password=<password> Login password or passphrase -S, --password-script=<script> Script to retrieve password -x, --ssh SSH connection (Default Value: 1) -k, --identity-file=<filename> Identity file for ssh -n <id> Name of the partition Partition name -s <id> Name of the managed system Managed system name -H, --hmc-version=<version> Force HMC version to use (3 or 4) (Default Value: 4) -c, --command-prompt=<prompt> Force command prompt (Default Value: [':~>', ']$', '$ ']) -4, --inet4-only Forces agent to use IPv4 addresses only -6, --inet6-only Forces agent to use IPv6 addresses only -u, --ipport=<port> TCP port to use for connection with device -v, --verbose Verbose mode -D, --debug-file=<debugfile> Write debug information to given file -V, --version Display version information and exit -h, --help Display help and exit -C, --separator=<char> Separator for CSV created by operation list (Default Value: ,) --power-timeout Test X seconds for status change after ON/OFF (Default Value: 20) --shell-timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) --login-timeout Wait X seconds for cmd prompt after login (Default Value: 15) --power-wait Wait X seconds after issuing ON/OFF (Default Value: 0) --delay Wait X seconds before fencing is started (Default Value: 0) --retry-on Count of attempts to retry power on (Default Value: 1) ACTIONS
on Power on machine. off Power off machine. reboot Reboot machine. status This returns the status of the plug/virtual machine. list List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise. monitor Check if fencing device is running. List available plugs/virtual machines or get status of machine (if it does not support more). metadata The operational behavior of this is not known. STDIN PARAMETERS
action Fencing Action (Default Value: reboot) ipaddr IP Address or Hostname This parameter is always required. login Login Name This parameter is always required. passwd Login password or passphrase passwd_script Script to retrieve password secure SSH connection (Default Value: 1) identity_file Identity file for ssh partition Partition name managed Managed system name hmc_version Force HMC version to use (3 or 4) (Default Value: 4) cmd_prompt Force command prompt (Default Value: [':~>', ']$', '$ ']) inet4_only Forces agent to use IPv4 addresses only inet6_only Forces agent to use IPv6 addresses only ipport TCP port to use for connection with device verbose Verbose mode debug Write debug information to given file version Display version information and exit help Display help and exit separator Separator for CSV created by operation list (Default Value: ,) power_timeout Test X seconds for status change after ON/OFF (Default Value: 20) shell_timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) login_timeout Wait X seconds for cmd prompt after login (Default Value: 15) power_wait Wait X seconds after issuing ON/OFF (Default Value: 0) delay Wait X seconds before fencing is started (Default Value: 0) retry_on Count of attempts to retry power on (Default Value: 1) fence_lpar (Fence Agent) 2009-10-20 FENCE_AGENT(8)
All times are GMT -4. The time now is 12:41 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy