Sponsored Content
Full Discussion: Search command on vi editor
Top Forums UNIX for Dummies Questions & Answers Search command on vi editor Post 302104153 by *Jess* on Tuesday 23rd of January 2007 07:47:43 PM
Old 01-23-2007
Search command on vi editor

Hi all,

Here is an example, I would wan to search for all string consists of IMP but not IMP-00015. Values other than 00015 is fine, is there anyone knows how to do that?

Thanks.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

vi editor - ex Command help

:1,10 s/yes/no/g this ex command will substitute yes with no everytime it is found within the first 10 lines of the file. :s/yes/no/g this ex command will substitute yes with no everytime it is found for the line where the cursor is on my question is how could this substitution be... (4 Replies)
Discussion started by: theDirtiest
4 Replies

2. UNIX for Dummies Questions & Answers

editor command

I want to copy lines say from 2-5 to line after 20 in vi editor. Can I achieve this in a single command in vi editor. Thanks. (2 Replies)
Discussion started by: tselvanin
2 Replies

3. UNIX for Dummies Questions & Answers

vim as command line editor

Here is my problem, I manage a SunOs 5.8 Server, vi is the default command line editor, I have a line on each users .kshrc profile as follows: export EDITOR=/bin/vi I want to use vim as the command line editor, the below line doesn't work export EDITOR=/bin/vim Thank you (1 Reply)
Discussion started by: tony3101
1 Replies

4. Shell Programming and Scripting

set EDITOR=vi -> default editor not setting for cron tab

Hi All, I am running a script , working very fine on cmd prompt. The problem is that when I open do crontab -e even after setting editor to vi by set EDITOR=vi it does not open a vi editor , rather it do as below..... ///////////////////////////////////////////////////// $ set... (6 Replies)
Discussion started by: aarora_98
6 Replies

5. UNIX for Dummies Questions & Answers

Files search in vi editor

Hi All, Apologise if I am in the wrong forum, I am trying to view all files one by one in the vi editor that contain a pattern. This command work but not sure where to pipe it to use vi editor find . -name "pattern" -print | xargs -ltr tnx in advance (1 Reply)
Discussion started by: lingosa
1 Replies

6. Shell Programming and Scripting

Easy ex editor command

I've this command in a script which edits the file ... bash$ cat temp_file.txt THREAD #2 2 Running bash$ (echo "s/THREAD #2/d"; echo 'wq') | ex -s temp_file.txt bash$ cat temp_file.txt THREAD #2 2 Running If i've more than 1 line it easily deletes the line, but if it is the last line... (3 Replies)
Discussion started by: prash184u
3 Replies

7. Shell Programming and Scripting

How to search number of occurrences of a particular string in a file through vi editor?

i have one file, i am doing 'vi Filename' now i want to search for particular string and i want to know how many times that string occurs in whole file (5 Replies)
Discussion started by: sheelsadan
5 Replies

8. UNIX for Dummies Questions & Answers

Command to quit from vi editor

Hi Folks I have opened a log file in Vi editor vi abc.logPlease advise me how to finally quit from Vi editor, which command is there..! Is it :q<Enter> (1 Reply)
Discussion started by: KAREENA18
1 Replies

9. UNIX for Beginners Questions & Answers

Accessing Isql command via VI editor

Hi Guru's, I'm new at Unix. I am tasked to monitor the filesystem utilization on OS level (Unix) and DB (Sybase) for multiple systems. I am thinking to use vi editor and make a file, execute that file and all the file systems I need to monitor will be be shown. My script inside vi goes in... (8 Replies)
Discussion started by: Xworks
8 Replies

10. Shell Programming and Scripting

Help with regular command creation for editor vi

Hi, I need help. I need to build command for line command editor vi. I want to take the whole string and assemble it in a regular expression. He then folded into another shape. Can anyone help me? (4 Replies)
Discussion started by: Pabloss
4 Replies
POWERCOM(8)							    NUT Manual							       POWERCOM(8)

NAME
powercom - UPS driver for Powercom/Trust/Advice UPS equipment NOTE
This man page only documents the hardware-specific features of the powercom driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
This driver supports many similar kinds of UPS hardware. The most common ones are the Trust 425/625, Powercom, and Advice Partner/King PR750. Others using the same protocol may also work. EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5) file: linevoltage=value An integer specifying the line voltage. It can't be auto detected. Acceptable values are in the range of 110-120 or 220-240. The default is 230. manufacturer=name Specify the manufacturer name, which also can't be auto detected. This is a user defined string, so any name is acceptable. The default is PowerCom. modelname=name Specify the model name, which also can't be auto detected. This is a user defined string, so any name is acceptable. The default is Unknown. serialnumber=value Like modelname above, but for the serial number. The default is Unknown. type=name The exact type of the communication protocol within the powercom family, that will be used to communicate with the UPS. The type is named after the first modelname that was coded with that protocol. The acceptable names are Trust, Egys, KP625AP, IMP, KIN, BNT, and BNT-other. The default is Trust. BNT-other is a special type for other BNT models (such as the 1500A at 120V and can be used to override ALL models using ALL of the following values. shutdownArguments={{minutes,seconds},whether_minutes_should_be_used} The minutes and seconds that the UPS should wait between receiving the shutdown command and actually shutting off. The other argument should be set to the character n only when the minutes value should be skipped and not sent to the UPS. The default is type-dependent and is given below. The braces and commas are mandatory. Note that there should be no whitespace characters. numOfBytesFromUPS=value The number of bytes in a UPS frame: 16 is common, 11 for Trust. The default is type-dependent and is given below. methodOfFlowControl=name The method of serial communication flow control that is engaged by the UPS. The default is type-dependent and is given below. Acceptable names are dtr0rts1, dtr1 or no_flow_control. validationSequence={{index1,value1},{index2,value2},{index3,value3}} (Only for types KP625AP, Trust, Egys.) 3 pairs to be used for validating the UPS by comparing bytes of the raw data with constant values. The index selects the byte from the UPS (see numOfBytesFromUPS) and the value is for matching to the byte. The default is type-dependent and is given below. The braces and commas are mandatory, as the lack of white space characters. frequency={A,B} (Only for types KP625AP, Trust, Egys.) A pair to convert the raw frequency data to a human-readable frequency reading using the function 1/(A*x+B). If the raw value x IS the frequency, then set A=1/(x^2) and B=0. The default is type-dependent and is given below. Do note that the braces and commas are mandatory as well, as the lack of whitespace characters. loadPercentage={BatteryA,BatteryB,LineA,LineB} (Only for types KP625AP, Trust, Egys.) A quad to convert the raw load data to human readable load percentage reading using the function A*x+B. If the raw value x IS the Load Percent, then set A=1 and B=0. The default is type-dependent and is given below. Do note that the braces and commas are mandatory, as the lack of white space characters. batteryPercentage={Battery1,Battery2,Battery3,Line4,Line5} (Only for KP625AP, Trust, Egys.) A 5 tuple to convert the raw battery and line data to a human-readable battery and line percentage reading using the functions (Battery) A*x+B*y+C and (Line) D*x+E. If the raw value x IS the Battery Percent, then set A=1, B=0, C=0, D=1, E=0. The default is type-dependent and is given below. Do note that the braces and commas are mandatory, as the lack of white space characters. voltage={240A,240B,120A,120B} (Only for types KP625AP, Trust, Egys.) A quad that is used convert the raw voltage data to a human-readable voltage reading using the function A*x+B. If the raw value x IS HALF the Voltage, then set A=2, B=0. The default is type-dependent and is given below. Do note that the braces and commas are mandatory, as well as the lack of whitespace characters. DEFAULT VALUES FOR THE EXTRA ARGUMENTS
linevoltage = 230 manufacturer = PowerCom modelname = Unknown serialnumber = Unknown type = Trust The rest of the default values for the extra arguments are type-dependent. However, BNT-other is a special type that can be used to override ALL values for ALL models. Trust numOfBytesFromUPS = 11 methodOfFlowControl = dtr0rts1 validationSequence = {{5,0},{7,0},{8,0}} shutdownArguments = {{0,10},n} frequency = {0.00020997,0.00020928} loadPercentage = {6.1343,-0.3808,4.3110,0.1811} batteryPercentage = {5.0000,0.3268,-825.00,4.5639,-835.82} voltage = {1.9216,-0.0977,0.9545,0.0000} KP625AP numOfBytesFromUPS = 16 methodOfFlowControl = dtr0rts1 validationSequence = {{5,0x80},{7,0},{8,0}} shutdownArguments = {{0,10},n} frequency = {0.00020997,0.00020928} loadPercentage = {6.1343,-0.3808,4.3110,0.1811} batteryPercentage = {5.0000,0.3268,-825.00,4.5639,-835.82} voltage = {1.9216,-0.0977,0.9545,0.0000} Egys numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{5,0x80},{7,0},{8,0}} shutdownArguments = {{0,10},n} frequency = {0.00020997,0.00020928} loadPercentage = {6.1343,-0.3808,1.3333,0.6667} batteryPercentage = {5.0000,0.3268,-825.00,2.2105,-355.37} voltage = {1.9216,-0.0977,0.9545,0.0000} IMP numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{5,0xFF},{7,0},{8,0}} shutdownArguments = {{1,30},y} KIN numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{11,0x4b},{8,0},{8,0}} shutdownArguments = {{1,30},y} BNT numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{11,0x42},{8,0},{8,0}} shutdownArguments = {{1,30},y} BNT-other numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{8,0},{8,0},{8,0}} shutdownArguments = {{1,30},y} frequency = {0.00027778,0.0000} loadPercentage = {1.0000,0.0,1.0000,0.0} batteryPercentage = {1.0000,0.0000,0.0000,1.0000,0.0000} voltage = {2.0000,0.0000,2.0000,0.0000} AUTHOR
Peter Bieringer <pb@bieringer.de>, Alexey Sidorov <alexsid@altlinux.org>, Keven L. Ates <atescomp@gmail.com> SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 POWERCOM(8)
All times are GMT -4. The time now is 08:03 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy