Sponsored Content
Full Discussion: Connected or not connected !
Top Forums Programming Connected or not connected ! Post 302103744 by XinU* on Sunday 21st of January 2007 08:48:24 AM
Old 01-21-2007
hello !
it is been a long time since u post your problem, so are u having same problems as mentioned ? or solved ? Smilie if not it might be a solution.
 

10 More Discussions You Might Find Interesting

1. AIX

How can I get Information about who is connected???

Hello, I'm new here and I come from Germany. At our AIX-ORACLE-System someone has deleted one important file and we'd like to find out who did this, next time. Is there any command to find out who is connected? I'm not trying to find out if it's root, etc., I'd like to get the DNS-Name or... (3 Replies)
Discussion started by: Huch
3 Replies

2. SCO

SCO connected Monitors

Hi all, we have 5 monitors connected to a SCO server using it's IP address(192.168.1.1), the server got busted, we have another similar server to connect the monitors to , how can i change the IP address of the new server to be (192.168.1.1), and connect the monitors to it. thanks, Marcel (1 Reply)
Discussion started by: marcelious
1 Replies

3. AIX

p550 connected to a HMC

Morning, I've installed a new p550 into a rack and connected it up to the HMC but the HMC cannot find it, I don't understand why it's not? Has anyone else had this problem before? Thanks Kees (4 Replies)
Discussion started by: KeesH
4 Replies

4. IP Networking

check whether connected to network

hi... can anyone pls suggest a few methods to check whether a computer is connected to any network, using the terminal, not GUI. thanks eskay (1 Reply)
Discussion started by: eskay_karthik
1 Replies

5. UNIX for Advanced & Expert Users

linux connected to as400

we have a as400 5rev4 and want to use a rhel server to use as a file server. We exported a drive on the rhel box and then mounted it on the as400. We can see the top directory in our mounted as400 directory but when we attempt access subdirectories we get a no matching object error. When we open... (2 Replies)
Discussion started by: javagair
2 Replies

6. AIX

How do I know to which storage I am connected

Hello everyone. We have a environment where we have DS8K storage and ES800 storage, the way to check to which storage the box is connected is using the LUN ID I get frm " pcmpath query device " command. for ex: 75CXX - DS8K storage 26860 - ES 800 Storage I was told to check... (4 Replies)
Discussion started by: nivaspIND
4 Replies

7. IP Networking

Am I Connected?

Be Gentle folks, I am a baby OpenSuSe 11.2 user :-) In windows Vista, there is a world in the systray when you are Internet connected and not just local. I have searched all over for a .RPM for the Network Manager or another packeg in Suse that can show me the same thing or something close. ... (0 Replies)
Discussion started by: donmaxwelliii
0 Replies

8. Shell Programming and Scripting

Mysql is not connected in php

Hi, The php is not able to connect into my mysql database. But i can able to connect by manually. I think that I have missed some points. Please guild for the same. Thanks, Mani (1 Reply)
Discussion started by: Mani_apr08
1 Replies

9. UNIX for Dummies Questions & Answers

Non Internet connected distribution

Hi all I've been a Debian user since solidly since about 1997 so I'm fairly experienced Linux user as a whole but unfortunately the monoculture has hit be hard recently. I'm working off a Laptop a lot of the time which spends up to 2-4 weeks without an Internet connection. A few weeks ago it... (1 Reply)
Discussion started by: pointyhat
1 Replies

10. IP Networking

Connected to IANA anyway, why?

May someone can answer this. Anytime I ignite my laptop to go online I see via etherape that I am connected to IANA as shown below. Is my provider redirecting me there, the cable under the sea, what is the reason for this? This happened with a pretty normal desktop PC, as well with my ancient... (2 Replies)
Discussion started by: 1in10
2 Replies
SLAGTS(l)								 )								 SLAGTS(l)

NAME
SLAGTS - may be used to solve one of the systems of equations (T - lambda*I)*x = y or (T - lambda*I)'*x = y, SYNOPSIS
SUBROUTINE SLAGTS( JOB, N, A, B, C, D, IN, Y, TOL, INFO ) INTEGER INFO, JOB, N REAL TOL INTEGER IN( * ) REAL A( * ), B( * ), C( * ), D( * ), Y( * ) PURPOSE
SLAGTS may be used to solve one of the systems of equations (T - lambda*I)*x = y or (T - lambda*I)'*x = y, where T is an n by n tridiagonal matrix, for x, following the factorization of (T - lambda*I) as (T - lambda*I) = P*L*U , by routine SLAGTF. The choice of equation to be solved is controlled by the argument JOB, and in each case there is an option to perturb zero or very small diagonal elements of U, this option being intended for use in applications such as inverse iteration. ARGUMENTS
JOB (input) INTEGER Specifies the job to be performed by SLAGTS as follows: = 1: The equations (T - lambda*I)x = y are to be solved, but diagonal elements of U are not to be perturbed. = -1: The equa- tions (T - lambda*I)x = y are to be solved and, if overflow would otherwise occur, the diagonal elements of U are to be per- turbed. See argument TOL below. = 2: The equations (T - lambda*I)'x = y are to be solved, but diagonal elements of U are not to be perturbed. = -2: The equations (T - lambda*I)'x = y are to be solved and, if overflow would otherwise occur, the diagonal elements of U are to be perturbed. See argument TOL below. N (input) INTEGER The order of the matrix T. A (input) REAL array, dimension (N) On entry, A must contain the diagonal elements of U as returned from SLAGTF. B (input) REAL array, dimension (N-1) On entry, B must contain the first super-diagonal elements of U as returned from SLAGTF. C (input) REAL array, dimension (N-1) On entry, C must contain the sub-diagonal elements of L as returned from SLAGTF. D (input) REAL array, dimension (N-2) On entry, D must contain the second super-diagonal elements of U as returned from SLAGTF. IN (input) INTEGER array, dimension (N) On entry, IN must contain details of the matrix P as returned from SLAGTF. Y (input/output) REAL array, dimension (N) On entry, the right hand side vector y. On exit, Y is overwritten by the solution vector x. TOL (input/output) REAL On entry, with JOB .lt. 0, TOL should be the minimum perturbation to be made to very small diagonal elements of U. TOL should normally be chosen as about eps*norm(U), where eps is the relative machine precision, but if TOL is supplied as non-positive, then it is reset to eps*max( abs( u(i,j) ) ). If JOB .gt. 0 then TOL is not referenced. On exit, TOL is changed as described above, only if TOL is non-positive on entry. Otherwise TOL is unchanged. INFO (output) INTEGER = 0 : successful exit element of the solution vector x. This can only occur when JOB is supplied as positive and either means that a diagonal element of U is very small, or that the elements of the right-hand side vector y are very large. LAPACK version 3.0 15 June 2000 SLAGTS(l)
All times are GMT -4. The time now is 11:19 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy