Sponsored Content
Operating Systems Solaris [help]network error after reboot server v890 sparc Post 302091103 by grial on Friday 29th of September 2006 05:23:36 AM
Old 09-29-2006
Are you using mirrors?
Check the output of "metastat", just in case Smilie
Perhaps you need some "metasync" or have some kind of error in your mirros...

Regards.
 

10 More Discussions You Might Find Interesting

1. Solaris

Network Connectivity lost after reboot

I have 4 V440 servers running Solaris 9. I have their interfaces configured (ce0) and have connectivity to our network. However, after reboot,...the connectivity is lost although the interface shows that its still up after an ifconfig -a. Only after I reconfigure the interface do I restore... (19 Replies)
Discussion started by: StorageGuy
19 Replies

2. Solaris

[HELP] mirroring disk at solaris 8 sparc v890

hi expert, sorry i'm new in solaris system, need more advice and help :) i'm confusing with mirroring disk at my sparc v890 solaris 8, i have 6 harddisk which the structure shown below : format : AVAILABLE DISK SELECTIONS: 0. c1t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848> ... (4 Replies)
Discussion started by: bucci
4 Replies

3. Solaris

[need help] error after configure network card at v890 sparc

hi experts, i have some problem with my server v890, i had config the network with ce0,ce1 and eri0 but after reboot the server have this error messages display : WARNING: ce0: fault detected external to device; service degraded WARNING: ce0: xcvr addr:0x01 - link down configuring IPv4... (2 Replies)
Discussion started by: bucci
2 Replies

4. Solaris

[need help] about after running sys-unconfig and config network for v890

hi expert, i had do sys-unconfig for my v890 sparc and had config for eri0 network interface and hostname but after the server bring up i got this error messages : NIS domainname is www.USSDGmdn-4.com starting rpc services: rpcbind keyserv done. Setting netmask of eri0 to 255.255.255.0... (5 Replies)
Discussion started by: bucci
5 Replies

5. SCO

Network lost after reboot

Hi .. can anyone help with this pleeaasse .. I have a Sco Unixware 7.1.0 server which has been running fine for nearly 10 years ... we have not had to do any os changes for several years. We tend to reboot it about once a month just to keep everthing clean! My issue is that we have just... (7 Replies)
Discussion started by: DickTutton
7 Replies

6. Solaris

Break command on rsc of sunfire v890 server

Hi Gurus I would like to know whether break command always work well means take the system to ok> prompt. Its depend upon sever model also. As I am facing problem when ever my system ( Sunfire V890 ) having Solaris 10 OS & oracle RAC on it goes to hang state then I run the break command from... (6 Replies)
Discussion started by: girish.batra
6 Replies

7. Solaris

SunFire V890 error -256 when boot

Hi all! I've a machine - SunFire V890, it've been failed by OS error for 2 weeks ago, and now, I must reinstall OS (Solaris 10 2009), the progress was successful, but when I reboot, it displayed the error like : Error -256: Last trap memory ... access aligned Error -256: Last trap memory... (1 Reply)
Discussion started by: trantuananh24hg
1 Replies

8. SuSE

reboot and boot from network

Hello, Does any one know any command which reboot the system and select as boot device the network. I give bootnet to many servers at once and i want to avoid opening ILOM and select as boot device the network. Can i do it by just executing a command? Thanks in advance (2 Replies)
Discussion started by: @dagio
2 Replies

9. Solaris

Service error on sparc server running solaris 10

Hi, I am getting following service error on one of the sparc servers running solaris 10 - Code : $ svcs -a | grep "maintenance" maintenance Nov_08 svc:/application/management/sma:default $ svcs -xv svc:/application/management/sma:default (net-snmp SNMP daemon) State: maintenance... (8 Replies)
Discussion started by: sunadmin
8 Replies

10. Solaris

External Network Connectivity w/Oracle VM Server for SPARC & Solaris 11

Hello all, thanks for reading my question: So I've been a Unix/Linux SysAdmin for a couple years, and I'm a bit over my head running solo, trying to set up LDoms using Oracle VM Server 3.1 for SPARC. I've been very careful, and things have gone well up until the point I try to access the new... (9 Replies)
Discussion started by: Lyxix
9 Replies
metasync(1M)						  System Administration Commands					      metasync(1M)

NAME
metasync - handle metadevice resync during reboot SYNOPSIS
/usr/sbin/metasync -h /usr/sbin/metasync [-s setname] [buffer_size] metadevice /usr/sbin/metasync [-s setname] -r [buffer_size] /usr/sbin/metasync -p metadevice DESCRIPTION
The metasync command starts a resync operation on the specified metadevice. All components that need to be resynced are resynced. If the system crashes during a RAID5 initialization, or during a RAID5 resync, either an initialization or resync restarts when the system reboots. Applications are free to access a metadevice at the same time that it is being resynced by metasync. Also, metasync performs the copy oper- ations from inside the kernel, which makes the utility more efficient. Use the -r option in boot scripts to resync all possible submirrors. OPTIONS
The following options are supported: -h Displays usage message. -p metadevice Regenerates parity information for RAID5 metadevices. -s setname Specifies the name of the diskset on which metasync will work. Using the -s option will cause the command to perform its administrative function within the specified diskset. Without this option, the command will perform its function on local metadevices. -r Specifies that the metasync command handle special resync requirements during a system reboot. metasync -r should only be invoked from the svc:/system/mdmonitor service. The metasync command only resyncs those metadevices that need to be resynced. metasync schedules all the mirror resyncs according to their pass numbers. To override the default buffer_size value used by the svc:/system/mdmonitor service, you can edit /etc/system to specify: set md_mirror:md_resync_bufsz = 2048 so that resyncs occur as quickly as possible. OPERANDS
buffer_size Specifies the size (number of 512-byte disk blocks) of the internal copy buffer for the mirror resync. The size defaults to 128 512-byte disk blocks (64 Kbytes). It can be no more than 2048 blocks. For best performance (quick- est completion of the resync), 2048 blocks is the recommended size. EXIT STATUS
The following exit values are returned: 0 Successful completion. >0 An error occurred. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWmdu | +-----------------------------+-----------------------------+ SEE ALSO
mdmonitord(1M), metaclear(1M), metadb(1M), metadetach(1M), metahs(1M), metainit(1M), metaoffline(1M), metaonline(1M), metaparam(1M), metarecover(1M), metarename(1M), metareplace(1M), metaroot(1M), metaset(1M), metassist(1M), metastat(1M), metattach(1M), md.tab(4), md.cf(4), mddb.cf(4), md.tab(4), attributes(5), md(7D) Solaris Volume Manager Administration Guide NOTES
The metasync service is managed by the service management facility, smf(5), under the service identifier: svc:/system/mdmonitor Administrative actions on this service, such as enabling, disabling, or requesting restart, can be performed using svcadm(1M). The ser- vice's status can be queried using the svcs(1) command. SunOS 5.10 24 Nov 2004 metasync(1M)
All times are GMT -4. The time now is 10:55 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy