Sponsored Content
Operating Systems HP-UX BAD SUPER BLOCK - Run fsck with alternate super block number Post 302087044 by admin wanabee on Tuesday 29th of August 2006 01:27:57 PM
Old 08-29-2006
BAD SUPER BLOCK - Run fsck with alternate super block number

Error received when I tried to restore a blank disk with an 'auto recovery' DDS tape via HP-UX recovery system 2.0 onto a 1Gb SCSI. I assumed it would do the setup, wrong. Could someone tell me the procedure to initial disk for recovering files using cpio. The system is a HP-UX 9.04 version on a Motorola 68040, i.e. HP382 controller.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

incorrect super block FreeBSD

working with FreeBSD 4.5 trying to mount my floppy like i did in red hat like $mount /dev/fd0 /mnt/floppy but i get the answer :incorrect super block i thought maybe it needs format: $fdformat /dev/rfd0.1440 still doesn't work and the man pages and the site of FreeBSD don't really help me :(... (2 Replies)
Discussion started by: termiEEE
2 Replies

2. UNIX for Dummies Questions & Answers

Bad magic number in super-block

I am running mandrake 8.2 and when booting I get the message: e2fschk: Bad magic number in super-block while trying to open /dev/hda8. The superblock could not be read or does not describe a correct ext2 filesystem. If the device is valid and really contains a valid an ext2 filesystem (and... (1 Reply)
Discussion started by: Jay
1 Replies

3. Filesystems, Disks and Memory

Bad Super Block: Magic Number Wrong

I had a power outage a day ago and when the power came back on my FreeBSD 4.6 webserver had problems. It said it was unable to mount /var and made me start in single user mode and said to run fsck MANUALY. So i did and this is now what i get. www# fsck /dev/ad0s1e ** /dev/ad0s1e BAD SUPER... (4 Replies)
Discussion started by: matthewbane
4 Replies

4. Solaris

solaris error BAD SUPER BLOCK

I want mount a disk. I have this error. I'm trying to correct with the superblock but i have the same error. Look my procedure. bash-2.03# fsck -F ufs /dev/rdsk/c0t1d0s0 Alternate super block location: 9423392. ** /dev/rdsk/c0t1d0s0 BAD SUPER BLOCK: MAGIC NUMBER WRONG USE AN ALTERNATE... (1 Reply)
Discussion started by: simquest
1 Replies

5. Solaris

Failed To Read Super Block

Greetings: I am trying to re-install my system with the Solaris 9 CD. I typed boot cdrom from the OBP, the system restarted and started saying Failed To Read Super Block, and then proceeds to the screen where I was initially before I decided to re-install the OS. My system was working... (4 Replies)
Discussion started by: ogfunsho
4 Replies

6. UNIX for Dummies Questions & Answers

Failed To Read Super Block With Solaris 9

Greetings: I am trying to re-install my system with the Solaris 9 CD. I typed boot cdrom from the OBP, the system restarted and started saying Failed To Read Super Block, and then proceeds to the screen where I was initially before I decided to re-install the OS. My system was working... (0 Replies)
Discussion started by: ogfunsho
0 Replies

7. Filesystems, Disks and Memory

Bad super block: Magic number wrong

Whenever i run, # fsck -F ufs /dev/dsk/c0t0d0s7 The following error prompt out:- ** /dev/dsk/c0t0d0s7 BAD SUPER BLOCK: MAGIC NUMBER WRONG USE AN ALTERNATE SUPER-BLOCK TO SUPPLY NEEDED INFORMATION; eg. fsck -o b=# where # is the alternate super block. SEE fsck_ufs(1M). ... (3 Replies)
Discussion started by: beginningDBA
3 Replies

8. UNIX for Advanced & Expert Users

How can I run command with super user privledge

Hello All, I am working on UNIX like environment. This environment is ported from UNIX. Here when we need to build product set, we need to run some script with super user privledge (which we normal user dont have) Is there any way (some C program or some script) through which any normal... (2 Replies)
Discussion started by: joshi123
2 Replies

9. Filesystems, Disks and Memory

Can't repair super block, bad magic number

Hello all, I have a hard drive that I can't repair. The drive is WD15EARS - Filesystem ext4 ( not 100% sure ) It's used in a Synology DS110j NAS. I try to run fsck -p /dev/sdb on the HD and I get this: Bad magic number in super-block while trying to open /dev/sdb /dev/sdb: The superblock... (4 Replies)
Discussion started by: dallasw1983
4 Replies

10. Solaris

File System Error: BAD SUPERBLOCK AT BLOCK 16: NUMBER OF DIRECTORIES OUT OF RANGE

Hi All, we are having a file system error in one of our servers. The server failed to boot in usual user mode. Instead boot with single user mode and requesting to run a FSCK manually to repair the corrupted. see the below output. Netra T2000, No Keyboard Copyright 2008 Sun Microsystems,... (5 Replies)
Discussion started by: Buddhike G
5 Replies
vxsparecheck(1M)														  vxsparecheck(1M)

NAME
vxsparecheck - monitor Veritas Volume Manager for failure events and replace failed disks SYNOPSIS
/etc/vx/bin/vxsparecheck [mail-address...] DESCRIPTION
The vxsparecheck command monitors Veritas Volume Manager (VxVM) by analyzing the output of the vxnotify command, waiting for failures to occur. It then sends mail via mailx to the logins specified on the command line, or (by default) to root. It then replaces any failed disks. After an attempt at replacement is complete, mail will be sent indicating the status of each disk replacement. The mail notification that is sent when a failure is detected follows this format: Failures have been detected by the Veritas Volume Manager: failed disks: medianame ... failed plexes: plexname ... failed subdisks: subdiskname ... failed volumes: volumename ... The Volume Manager will attempt to find hot-spare disks to replace any failed disks and attempt to reconstruct any data in volumes that have storage on the failed disk. The medianame list specifies disks that appear to have completely failed. The plexname list show plexes of mirrored volumes that have been detached due to I/O failures experienced while attempting to do I/O to subdisks they contain. The subdiskname list specifies subdisks in RAID-5 volumes that have been detached due to I/O errors. The volumename list shows non-RAID-5 volumes that have become unusable because disks in all of their plexes have failed (and are listed in the ``failed disks'' list) and shows those RAID-5 volumes that have become unusable because of multiple failures. If any volumes appear to have failed, the following paragraph will be included in the mail: The data in the failed volumes listed above is no longer available. It will need to be restored from backup. Replacement Procedure After mail has been sent, vxsparecheck finds a hot spare replacement for any disks that appear to have failed (that is, those listed in the medianame list). This involves finding an appropriate replacement for those eligible hot spares in the same disk group as the failed disk. A disk is eligible as a replacement if it is a valid Veritas Volume Manager disk (VM disk), has been marked as a hot-spare disk and con- tains enough space to hold the data contained in all the subdisks on the failed disk. To determine which disk from among the eligible hot spares to use, vxsparecheck first checks the file /etc/vx/sparelist (see Sparelist File below). If this file does not exist or lists no eligible hot spares for the failed disk, the disk that is ``closest'' to the failed disk is chosen. The value of ``closeness'' depends on the controller, target and disk number of the failed disk. A disk on the same controller as the failed disk is closer than a disk on a different controller; and a disk under the same target as the failed disk is closer than one under a different target. If no hot spare disk can be found, the following mail is sent: No hot spare could be found for disk medianame in diskgroup. No replacement has been made and the disk is still unusable. The mail then explains the disposition of volumes that had storage on the failed disk. The following message lists disks that had storage on the failed disk, but are still usable: The following volumes have storage on medianame: volumename These volumes are still usable, but the redundancy of those volumes is reduced. Any RAID-5 volumes with storage on the failed disk may become unusable in the face of further failures. If any non-RAID-5 volumes were made unusable due to the failure of the disk, the following message is included: The following volumes: volumename have data on medianame but have no other usable mirrors on other disks. These volumes are now unusable and the data on them is unavailable. If any RAID-5 volumes were made unavailable due to the disk failure, the following message is included The following RAID-5 volumes: volumename had storage on medianame and have experienced other failures. These RAID-5 volumes are now unusable and data on them is unavailable. If a hot-spare disk was found, a hot-spare replacement is attempted. This involves associating the device marked as a hot spare with the media record that was associated with the failed disk. If this is successful, the vxrecover(1M) command is used in the background to recover the contents of any data in volumes that had storage on the disk. If the hot-spare replacement fails, the following message is sent: Replacement of disk medianame in group diskgroup failed. The error is: error message If any volumes (RAID-5 or otherwise) are rendered unusable due to the failure, the following message is included: The following volumes: volumename occupy space on the failed disk and have no other available mirrors or have experienced other failures. These volumes are unusable, and the data they contain is unavailable. If the hot-spare replacement procedure completed successfully and recovery is under way, a final mail message is sent: Replacement of disk medianame in group diskgroup with disk device sparedevice has successfully completed and recovery is under way. If any non-RAID-5 volumes were rendered unusable by the failure despite the successful hot-spare procedure, the following message is included in the mail: The following volumes: volumename occupy spare on the replaced disk, but have no other enabled mirrors on other disks from which to perform recovery. These volumes must have their data restored. If any RAID-5 volumes were rendered unusable by the failure despite the successful hot-spare procedure, the following message is included in the mail: The following RAID-5 volumes: volumename have subdisks on the replaced disk and have experienced other failures that prevent recovery. These RAID-5 volumes must have their data restored. If any volumes (RAID-5 or otherwise) were rendered unusable, the following message is also included: To restore the contents of any volumes listed above, the volume should be started with the command: vxvol -f start volumename and the data restored from backup. Sparelist File The sparelist file is a text file that specifies an ordered list of disks to be used as hot spares when a specific disk fails. The system- wide sparelist file is located in /etc/vx/sparelist. Each line in the sparelist file specifies a list of spares for one disk. Lines beginning with the pound (#) character and empty lines are ignored. The format for a line in the sparelist file is: [ diskgroup:] diskname : spare1 [ spare2 ... ] The diskgroup field, if present, specifies the disk group within which the disk and designated spares reside. If this field is not speci- fied, the default disk group is determined using the rules given in the vxdg(1M) manual page. The diskname specifies the disk for which spares are being designated. The spare list after the colon lists the disks to be used as hot spares. The list is order dependent; in case of failure of diskname, the spares are tried in order. A spare will be used only if it is a valid hot spare (see above). If the list is exhausted without finding any spares, the default policy of using the closest disk is used. FILES
/etc/vx/sparelist Specifies a list of disks to serve as hot spares for a disk. NOTES
The sparelist file is not checked in any way for correctness until a disk failure occurs. It is possible to inadvertently specify a non- existent disk or inappropriate disk or disk group. Malformed lines are also ignored. SEE ALSO
mailx(1), vxintro(1M), vxnotify(1M), vxrecover(1M), vxrelocd(1M), vxunreloc(1M) VxVM 5.0.31.1 24 Mar 2008 vxsparecheck(1M)
All times are GMT -4. The time now is 11:58 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy