07-28-2006
prtdiag on solaris is only available for sun servers - not in solaris X86. I doubt that the issue is with the OS but with the platform - the p.c. doesn't have the ability to share a temperature with the OS ( see
pc temperature)
8 More Discussions You Might Find Interesting
1. HP-UX
I'm fairly new to hpux, so this is what i've been trying to figure out. Is it possible to get any logs on hpux that would indicate if the system, cpu, or other hardware components reached above normal or critical temperatures?
Thanks,
-K (0 Replies)
Discussion started by: uzerx
0 Replies
2. Solaris
Hi all
I have a SUN V480 server with 4 processores and I've noticed that the temperature for 2 of the 4 processers are quite high (63 degrees Celsius).
Does anyone know what the operating temperatures of the Sparc CPU's are? I'm not getting any warning messages yet, but I want to resolve the... (3 Replies)
Discussion started by: soliberus
3 Replies
3. Filesystems, Disks and Memory
Hi,
I just set up a raid Z array in solaris xpress and I notice that the drives feel pretty damn hot. I use speedfan to monitor the temperatures of the hard drives in XP. Is there a similar program for solrais? I assume there would be since the drives all have temp sensors in them, but I... (2 Replies)
Discussion started by: ciscocbee
2 Replies
4. Solaris
How to get a CPU temperature and current power consumption in T5220 server both from system controller and Operating system. I need details by cores. Thanks in advance. (13 Replies)
Discussion started by: fugitive
13 Replies
5. Shell Programming and Scripting
Dears,
need help on developing a script to monitor sun server temperature , I'm using the below command to check the servers one by one
/usr/platform/`uname -i`/sbin/prtdiag -v
Servers Models are :
2 x Sun SPARC Enterprise M9000 Server
4 x Sun Fire V490
2 x Sun Blade T6300 Server... (1 Reply)
Discussion started by: bejo4ever
1 Replies
6. Solaris
some say '/usr/sfw/bin/ipmitool' can be used to read temperature. has anyone tried it? what options should be used? (1 Reply)
Discussion started by: orange47
1 Replies
7. Shell Programming and Scripting
Hello,
I am trying to work on a temperature script to check temperatures on my systems. Im trying to get the basics laid out first. So far i have a command:
/usr/sbin/prtpicl -v -c temperature-sensor # (must run as root)
This command kicks back alot of information but i only want the... (3 Replies)
Discussion started by: whotippedmycow
3 Replies
8. Infrastructure Monitoring
Sorry if this is the wrong forum
Searching for Saas Monitor service which monitor my servers which are sitting in different providers .
This monitor tool will take as less CPU as possible , and will send info about the server to main Dashboard.
The info I need is CPU / RAM / my servers status (... (1 Reply)
Discussion started by: umen
1 Replies
LEARN ABOUT DEBIAN
amdtemp
AMDTEMP(4) BSD Kernel Interfaces Manual AMDTEMP(4)
NAME
amdtemp -- device driver for AMD K8, K10 and K11 on-die digital thermal sensor
SYNOPSIS
To compile this driver into the kernel, place the following line in your kernel configuration file:
device amdtemp
Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5):
amdtemp_load="YES"
DESCRIPTION
The amdtemp driver provides support for the on-die digital thermal sensor present in AMD K8, K10 and K11 processors.
For the K8 family, the amdtemp driver reports each cores' temperature through a sysctl node in the corresponding CPU devices's sysctl tree,
named dev.amdtemp.%d.sensor{0,1}.core{0,1}. The driver also creates dev.cpu.%d.temperature displaying the maximum temperature of the two
sensors located in each CPU core.
For the K10 and K11 families, the driver creates dev.cpu.%d.temperature with the temperature of each core.
BUGS
AMD K9 is not supported because temperature reporting has been replaced by Maltese.
SEE ALSO
sysctl(8)
HISTORY
The amdtemp driver first appeared in FreeBSD 7.1.
AUTHORS
Rui Paulo <rpaulo@FreeBSD.org>
Norikatsu Shigemura <nork@FreeBSD.org>
BSD
April 8, 2008 BSD