Sponsored Content
Operating Systems Solaris change NIC to 1000 Mbps full duplex Post 302074375 by azrealhk on Tuesday 23rd of May 2006 01:39:35 AM
Old 05-23-2006
Strange if you can get then your interface is correct
can you run

ndd -get /dev/eri adv_100fdx_cap
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Full duplex at HUB?

Ok at the moment I have a hub whit 5 computers connected to it. It's a 10/100 NetGear hub. Ok I heard that there is some command I can run or a file I edit or something like that. But what the command/file/script/whatever does is tells you what connect speed it's connecting to the hub to. ... (4 Replies)
Discussion started by: merlin
4 Replies

2. UNIX for Dummies Questions & Answers

Full Duplex Howto

Dear Members, I was reading a few posts and saw something about installing two Nics so one could use Full Duplex. I remember back in the day of dial up, you could have two modems and use one for upstream and one for downstream. This was called shotgunning. It seems that you can now do the same... (4 Replies)
Discussion started by: Phobos
4 Replies

3. Programming

full -duplex ?

what is meant by full duplex and half duplex? b'coz in differences b\w hub and switch ,i heard lot this duplex word so please help me (1 Reply)
Discussion started by: parvathy
1 Replies

4. Solaris

How to force a full duplex

I need to change some Ip addresses for my servers to reflect in the NIS map. I also need to force full duplex on the 10/100 cards & 1/2 duplex in the 10 cards. I can change the IP by doing ifconfig <NIC card > plumb up <newip>. Not quite sure on how to force the full / half duplex & how to... (2 Replies)
Discussion started by: Remi
2 Replies

5. IP Networking

NIC speed 100M/full duplex problem

I have a TOSHIBA AS7000 B150 Sun Box I wanted to run it with 100M/full duplex I had added this to the /etc/system file to make to setting permenant So it would be set correctly on reboot. set eri:eri_adv_100fdx_cap=1 set eri:eri_adv_100hdx_cap=0 set eri:eri_adv_autoneg_cap=0 But when I... (4 Replies)
Discussion started by: AirWalker83
4 Replies

6. SuSE

configure full duplex

How do I configure full duplex on suse 8.2 I tried ethtool -s eth0 speed 100 duplex full autoneg off the above works but when I reboot the machine the configure was lost. How do I configure full duplex so that when the machine get rebooted the configuration will stay. My interface... (4 Replies)
Discussion started by: hassan2
4 Replies

7. Solaris

How to find half duplex or full duplex

Hi, How to find whether the server is running with half duplex or full duplex. I tried with the following command ndd -get /dev/ but am not getting any output,. Is the command correct? Also let me know how to change from half to full duplex. (1 Reply)
Discussion started by: rogerben
1 Replies

8. Programming

C++/Java full-duplex communication

Hello, here's my situation: I have a C++ server running on a well known machine and a number of Java clients running on other machines (assumed as unknown) on the same LAN. What I want to achieve is full duplex communication between those applications, in order to exchange complex objects and data... (3 Replies)
Discussion started by: demerzel3
3 Replies

9. Solaris

Haed code nxge0 nic interface with full duplex & 1000mbps

Hi All I would need to do hard code of nxge0 nic to full duplex & 1000mbps. So that whenever solaris server come up after reboot. it will show full duplex & 1000mbps setting only. Please also let me know how to do it online through command. regards (0 Replies)
Discussion started by: amity
0 Replies
sfe(7D) 							      Devices								   sfe(7D)

NAME
sfe - SiS900 series Fast Ethernet device driver SYNOPSIS
/dev/sfe DESCRIPTION
The sfe driver is a loadable, clonable, GLD-based STREAMS driver supporting the Data Link Provider Interface dlpi(7P) on Silicon Inte- grated Systems 900 series Fast Ethernet controllers. APPLICATION PROGRAMMING INTERFACE
The relevant fields returned as part of a DL_INFO_ACK response are: o Maximum SDU is 1500. o Minimum SDU is 0. o The dlsap address length is 8. o MAC type is DL_ETHER. o SAP length is -2. The 6-byte physical address is followed immediately by a 2-byte SAP. o Service mode is DL_CLDLS. o Broadcast address is the 6-byte Ethernet broadcast address (ff:ff:ff:ff:ff:ff). If the SAP provided is zero, then IEEE 802.3 mode is assumed and outbound frames will have the frame payload length written into the type field. Likewise, inbound frames with a SAP between zero and 1500 are interpreted as IEEE 802.3 frames and delivered to any streams that are bound to SAP zero (the 802.3 SAP). PROPERTIES
The following properties may be configured using either ndd(1M) or the sfe.conf configuration file as described by driver.conf(4): adv_100fdx_cap Enables the 100 Base TX full-duplex link option. (This is generally the fastest mode if both link partners support it. Most modern equipment supports this mode.) adv_100hdx_cap Enables the 100 Base TX half-duplex link option. (Typically used when the link partner is a 100 Mbps hub.) adv_10fdx_cap Enables the 10 Base-T full-duplex link option. (This less-frequently used mode is typically used when the link partner is a 10 Mbps switch.) adv_10hdx_cap Enables the 10 Base-T half-duplex link option. (This is the fall-back when no other option is available. It is typically used when the link partner is a 10 Mbps hub or is an older network card.) ATTRIBUTES
See attributes(5) for a description of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SPARC, x86 | +-----------------------------+-----------------------------+ |Interface Stability |Committed | +-----------------------------+-----------------------------+ FILES
/dev/sfe Special character device. /kernel/drv/sfe 32-bit driver binary (x86). /kernel/drv/amd64/sfe 64-bit driver binary (x86). /kernel/drv/sparcv9/sfe 64-bit driver binary (SPARC). /kernel/drv/sfe.conf Configuration file. SEE ALSO
ndd(1M), driver.conf(4), attributes(5), streamio(7I), dlpi(7P) IEEE 802.3 -- Institute of Electrical and Electronics Engineers, 2002 SunOS 5.11 12 Dec 2007 sfe(7D)
All times are GMT -4. The time now is 07:20 AM.