05-06-2002
You could check to see if the software is loaded but that doesn't mean it is being used. You may also miss the software (Solaris has it's own - DiskSuite but many use the Veritas Volume Manager). Each OS will be different so the easiest way to see it is to use df -k.
Veritas commands that may help you: vxprint, vxstat, vxdisk list.
DiskSuite (Solaris only): metastat
I'm sure the commands to check on AIX, HP-UX, and others are completely different - which is why df -k is used.
9 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hi there,
could someone please tell me, what the command is called, that does the calculations which help the system to fill gaps, resulting out of loss of discs, in RAID5?!
Thank you in advance,
Felida
(something like ...all?!) (2 Replies)
Discussion started by: felida
2 Replies
2. UNIX for Advanced & Expert Users
Hello there guys ,
I have this problem , i have this hp smart array 641 raid card and i'm trying to install sco unix 5.0.7 and is says no root disk found right before the instalation is about to start.
I know that you have to load the driver befor the install bud i really cannot find the... (0 Replies)
Discussion started by: josramon
0 Replies
3. HP-UX
I was wanting to know if anyone knew how to setup RAID 0 on an old HP Unix server. It's for where I work and my boss has two hard drives and wants the second to take over if the first one fails hence RAID 0. If anyone could help me it would be greatly appreciated. (5 Replies)
Discussion started by: zmachine04
5 Replies
4. UNIX for Dummies Questions & Answers
How do you view Drive/RAID configuration in UNIX?
We are running an ML370 with 6 drives in it...
Version: Sco 5.2.0
Sco Openserver Release 5 (2 Replies)
Discussion started by: bpoulson
2 Replies
5. SCO
Dear Team ,
how i can configure raid 1 (mirroring) using ide hdd in sco open unix 5
i have two 80gb identical hdd (same make/model)
thanx (0 Replies)
Discussion started by: sudhir69
0 Replies
6. AIX
Hello,
I have a scsi pci x raid controller card on which I had created a disk array of 3 disks
when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk )
suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies
7. HP-UX
Hi Gurus,
Can anyone tell me the Hardware RAID configuration in HP Unix rp3440 model server containing HP UX B.11.11 OS version.
Thanks in Advance.
BR,
Prasanth (3 Replies)
Discussion started by: prasanth438
3 Replies
8. Red Hat
Hello,
I want to delete a RAID configuration an old server has.
Since i haven't the chance to work with the specific raid controller in the past can you please help me how to perform the configuraiton?
I downloaded IBM ServeRAID Support CD but i wasn't able to configure the video card so i... (0 Replies)
Discussion started by: @dagio
0 Replies
9. SCO
I need to be able to make a backup image of an OLD UNIX server HD where I can restore the complete HD from scratch if (when) the HD fails. This server runs the accounting system for a company.
I can and have backed the data up via local FTP, but O/S and Apps are so old that I am not sure I could... (21 Replies)
Discussion started by: chrishouse
21 Replies
mdlogd(1M) System Administration Commands mdlogd(1M)
NAME
mdlogd - Solaris Volume Manager daemon
SYNOPSIS
mdlogd
DESCRIPTION
mdlogd implements a simple daemon that watches the system console looking for messages written by the Solaris Volume Manger. When a Solaris
Volume Manager message is detected, mdlogd sends a generic SNMP trap.
To enable traps, you must configure mdlogd into the SNMP framework. See Solaris Volume Manager Administration Guide.
USAGE
mdlogd implements the following SNMP MIB:
SOLARIS-VOLUME-MGR-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises FROM RFC1155-SMI
DisplayString FROM SNMPv2-TC;
-- Sun Private MIB for Solaris Volume Manager
sun OBJECT IDENTIFIER ::= { enterprises 42 }
sunSVM OBJECT IDENTIFIER ::= { sun 104 }
-- this is actually just the string from /dev/log that
-- matches the md: regular expressions.
-- This is an interim SNMP trap generator to provide
-- information until a more complete version is available.
-- this definition is a formalization of the old
-- Solaris DiskSuite mdlogd trap mib.
svmOldTrapString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the matched string that
was obtained from /dev/log."
::= { sunSVM 1 }
-- SVM Compatibility ( error trap )
svmNotice TrapTRAP-TYPE
ENTERPRISE sunSVM
VARIABLES { svmOldTrapString }
DESCRIPTION
"SVM error log trap for NOTICE.
This matches 'NOTICE: md:'"
::= 1
svmWarningTrap TRAP-TYPE
ENTERPRISE sunSVM
VARIABLES { svmOldTrapString }
DESCRIPTION
"SVM error log trap for WARNING..
This matches 'WARNING: md:'"
::= 2
svmPanicTrap TRAP-TYPE
ENTERPRISE sunSVM
VARIABLES { svmOldTrapString }
DESCRIPTION
"SVM error log traps for PANIC..
This matches 'PANIC: md:'"
::= 3
END
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Availability |SUNWlvma, SUNWlvmr |
+-----------------------------+-----------------------------+
|Interface Stability |Obsolete |
+-----------------------------+-----------------------------+
SEE ALSO
snmpdx(1M), attributes(5)
Solaris Volume Manager Administration Guide