12-23-2001
How can i set up Software disk mirroring(Raid1) in SCO 5.0.5 with two SCSI harddisk ?
thank u very much,
9 More Discussions You Might Find Interesting
1. Shell Programming and Scripting
Good Morning :)
I have a new challenge to solve, I am going to write a new backup disk mirroring script. The current one, whcih is useing 'dd' caused some stalled systems :(
Currently I am in the phase of experimenting with different methods, I was thinking about dump/restore afio/cpio or... (3 Replies)
Discussion started by: malcom
3 Replies
2. Solaris
Hi
I have two raw disk that I want to mirror and then create soft partition on that. Could someone please help in the steps required
c0t1d0
c0t0d0
Thanks
Ajwat (2 Replies)
Discussion started by: Ajwat
2 Replies
3. UNIX for Dummies Questions & Answers
hey guys this is my problem I have SCO unix installed on a IDE h/drive. I want to add a SCSI hard drive, how do i do that within UNIX (1 Reply)
Discussion started by: kwame.neilsen
1 Replies
4. Solaris
Hi
I have a Sunfire X4100 box with a 4 disk Chassis (although I only have 2 disks in it). I have been asked to add two more disks into the chassis so that I can mirror the original two using SVM .....Ive read through a couple of SVM docs but am finding it a little confusing, and if any of you... (1 Reply)
Discussion started by: hcclnoodles
1 Replies
5. Linux
Hi.
I have a SLES10 machine which until recently had only one disk. Now there is a second disk which I would like to mirror my OS installation to. I have three partitions, first one for /boot (~100M), the second one for / (~1G) and then the rest as a LVM partition with several volumes under... (0 Replies)
Discussion started by: Sprellarinn
0 Replies
6. SCO
please help me
i have two same server sco 5.0.6 and, one server os now not working
so i want to add same harddisk to my another same server ,after that i
can take backup it is so important please .
pankaj raval (6 Replies)
Discussion started by: pankajbraval
6 Replies
7. Solaris
hi every body
I'm new to solaris and I need your help in how to configure disk mirroring for 4 hard disks so that two of them will be replica to the other two ...???
Thanxx (7 Replies)
Discussion started by: mm00123
7 Replies
8. UNIX for Advanced & Expert Users
I have a HP proliant ML 570 G3 with two 146GB disk drives mirrored(RAID1+0)
windows server 2003 was installed on that disk.
I will add a disk.(scsi 300GB)
I will install Linux on that additional disk.
I want to create multiple-boot system.
Is it possible?
I wanna know how to create... (0 Replies)
Discussion started by: lifegeek
0 Replies
9. Ubuntu
Hello!
i am having a ubuntu server with two empty disks and connected software raid1 to it.
I am having /mnt/raid folder which i created to mount it.
SO should i now make a share folder inside that or what? I ama bit confused when a raid is present. (27 Replies)
Discussion started by: tomislav91
27 Replies
LEARN ABOUT HPUX
vparutil
vparutil(1M) vparutil(1M)
NAME
vparutil - get and set SCSI parameters for SCSI controllers from a virtual partition
SYNOPSIS
dev_path
dev_path
dev_path scsi_id] scsi_rate]
DESCRIPTION
The command gets and sets SCSI parameters for SCSI controllers within a running virtual partition. When setting the SCSI parameters using
the option, the virtual partition which owns the specified SCSI controller must be in the down state. If not, the command will fail with
the appropriate error code.
The SCSI parameters for a given SCSI controller must first be set (from the firmware BCH prompt or using the option) before the parameters
can be retrieved using the option.
The command is allowed on Itanium(R)-based platforms for compatibility. No action is taken for the command.
Options
recognizes the following command-line options:
Deletes an entry for the specified SCSI controller at
dev_path from the SCSI table.
Gets the SCSI parameters for the specified SCSI controller at
dev_path.
Sets the SCSI parameters for the specified SCSI controller at
dev_path.
Operands
recognizes the following command-line operands:
dev_path The device path of the SCSI controller.
id The SCSI ID for the specified controller (defaults to 7).
rate The SCSI rate for the specified controller. This parameter can have one of two values: for the corresponding fast wide and
ultra wide SCSI interfaces.
Note
For managing SCSI controllers, use corresponding SCSI utilities. For further information refer to
SECURITY RESTRICTIONS
This command is restricted to processes owned by superuser.
When virtual partition flexible administrative capability is enabled, only a Designated-Admin vPar can set SCSI parameters for SCSI con-
trollers.
EXAMPLES
Set the SCSI ID for controller at 0/0/2/0 to 3 with the fast wide rate:
RETURN VALUE
Successful.
Invalid SCSI controller specification.
Invalid SCSI ID.
Could not communicate with virtual partition monitor.
Virtual partition which owns SCSI controller is not in down state.
Internal firmware call failed.
Other error.
AUTHOR
was developed by the Hewlett-Packard Company.
SEE ALSO
vparadmin(1M), vparboot(1M), vparcreate(1M), vparconfig(1M), vpardump(1M), vparefiutil(1M), vparenv(1M), vparextract(1M), vparmodify(1M),
vparreloc(1M), vparremove(1M), vparreset(1M), vparstatus(1M), vparresources(5), vpartition(5), vpmon(5).
vparutil(1M)