Sponsored Content
Full Discussion: Sparc vs Intel performance
Top Forums UNIX for Dummies Questions & Answers Sparc vs Intel performance Post 11516 by doeboy on Thursday 6th of December 2001 04:12:55 PM
Old 12-06-2001
If both configurations would end up running Solaris 8, I'd say that SPARC would be the way to go hands down. Smilie

Personally, I'd get rid if IIS as well, but that's just me. Smilie
 

6 More Discussions You Might Find Interesting

1. News, Links, Events and Announcements

Announcing collectl - new performance linux performance monitor

About 4 years ago I wrote this tool inspired by Rob Urban's collect tool for DEC's Tru64 Unix. What makes this tool as different as collect was in its day is its ability to run at a low overhead and collect tons of stuff. I've expanded the general concept and even include data not available in... (0 Replies)
Discussion started by: MarkSeger
0 Replies

2. Red Hat

Red Hat and Intel: Smart processors, virtualization boost efficiency and performance

On Monday March 30, Intel announced the availability of their much anticipated new line of processors, the Intel® Xeon® Processor 5500 series–nicknamed Nehalem. Red Hat, a long-time partner of the market-leading chip maker , collaborated on the chip’s debut, testing and optimizing the... (0 Replies)
Discussion started by: Linux Bot
0 Replies

3. Solaris

How much better performance is ultra SPARC IV+ 1.95GHz than 1.35GHz?

Dear Guru, My boss has a plan to upgrade cpu of server so he needs to know how much better performance(percentage) is Ultra SPARC IV+ 1.95 GHz than Ultra SPARC IV 1.35 GHz?. I am looking for documentation to reference but I didn't see anything close to my point. If who know,... (3 Replies)
Discussion started by: unitipon
3 Replies

4. UNIX for Dummies Questions & Answers

can I emulate solaris/sparc on virtualbox? Or other emulator to run solaris for sparc in my win7 PC?

Hi Gurus can I emulate solaris/sparc on virtualbox? Or other emulator to run solaris for sparc in my win7 PC? regards, Israel. (9 Replies)
Discussion started by: iga3725
9 Replies

5. Programming

Padding issues between Sparc and Intel

Hello, I'm facing severe structure padding issues when my Solaris C/C++ application that runs on Sparc communicates with the same C/C++ application that runs on Intel. I know that Sparc and Intel use different padding patterns. So when it comes to reading the exchanged structure data, both... (11 Replies)
Discussion started by: Goseib
11 Replies

6. Solaris

Running Solaris SPARC on Intel Hardware????

Hello friends, I hope everyone is fine and doing well. I want to learn Assembly language for SPARC architecture. Is there any emulator available for 64 bit SPARC on which one can install Oracle Solaris 11 SPARC version. And ofcourse on my intel laptop computer??? Thanks! (4 Replies)
Discussion started by: gabam
4 Replies
Catalyst::Manual::Deployment::IIS::FastCGI(3pm) 	User Contributed Perl Documentation	   Catalyst::Manual::Deployment::IIS::FastCGI(3pm)

NAME
Catalyst::Manual::Deployment::IIS::FastCGI - Deploying Catalyst with Microsoft IIS Microsoft IIS It is possible to run Catalyst under IIS with FastCGI, but only on IIS 6.0 (Microsoft Windows 2003), IIS 7.0 (Microsoft Windows 2008 and Vista), and (hopefully) its successors. FastCGI is sometimes said to be supported on IIS 5.1 (Windows XP), but some features (specifically, wildcard mappings) are not supported. This prevents Catalyst applications from running on the server. Let us assume that our server has the following layout: d:WWWWebApp path to our Catalyst application d:strawberryperlinperl.exe path to perl interpreter (with Catalyst installed) c:windows Windows directory Setup IIS 6.0 (Windows 2003) Install FastCGI extension for IIS 6.0 FastCGI is not a standard part of IIS 6 - you have to install it separately. For more info and the download, go to <http://www.iis.net/extensions/FastCGI>. Choose the appropriate version (32-bit/64-bit); installation is quite simple (in fact no questions, no options). Create a new website Open "Control Panel" > "Administrative Tools" > "Internet Information Services Manager". Click "Action" > "New" > "Web Site". After you finish the installation wizard you need to go to the new website's properties. Set website properties On the tab "Web site", set proper values for: Site Description, IP Address, TCP Port, SSL Port, etc. On the tab "Home Directory" set the following: Local path: "d:WWWWebApp oot" Local path permission flags: check only "Read" + "Log visits" Execute permitions: "Scripts only" Click "Configuration" button (still on Home Directory tab) then click "Insert" the wildcard application mapping, and in the next dialog set: Executable: "c:windowssystem32inetsrvfcgiext.dll" Uncheck: "Verify that file exists" Close all dialogs with "OK". Edit fcgiext.ini Put the following lines into c:windowssystem32inetsrvfcgiext.ini (on 64-bit system c:windowssyswow64inetsrvfcgiext.ini): [Types] *:8=CatalystApp ;replace 8 with the identification number of the newly created website ;it is not so easy to get this number: ; - you can use utility "c:inetpubadminscriptsadsutil.vbs" ; to list websites: "cscript adsutil.vbs ENUM /P /W3SVC" ; to get site name: "cscript adsutil.vbs GET /W3SVC/<number>/ServerComment" ; to get all details: "cscript adsutil.vbs GET /W3SVC/<number>" ; - or look where are the logs located: ; c:WINDOWSSYSTEM32LogfilesW3SVC7whatever.log ; means that the corresponding number is "7" ;if you are running just one website using FastCGI you can use '*=CatalystApp' [CatalystApp] ExePath=d:strawberryperlinperl.exe Arguments="d:WWWWebAppscriptwebapp_fastcgi.pl -e" ;by setting this you can instruct IIS to serve Catalyst static files ;directly not via FastCGI (in case of any problems try 1) IgnoreExistingFiles=0 ;do not be fooled by Microsoft doc talking about "IgnoreExistingDirectories" ;that does not work and use "IgnoreDirectories" instead IgnoreDirectories=1 Setup IIS 7.0 (Windows 2008 and Vista) Microsoft IIS 7.0 has built-in support for FastCGI so you do not have to install any addons. Necessary steps during IIS7 installation During IIS7 installation, after you have added role "Web Server (IIS)" you need to check to install the role feature "CGI" (do not be nervous that it is not FastCGI). If you already have IIS7 installed you can add the "CGI" role feature through "Control panel" > "Programs and Features". Create a new website Open "Control Panel" > "Administrative Tools" > "Internet Information Services Manager" > "Add Web Site". site name: "CatalystSite" content directory: "d:WWWWebApp oot" binding: set proper IP address, port etc. Configure FastCGI You can configure FastCGI extension using commandline utility "c:windowssystem32inetsrvappcmd.exe" Configuring section "fastCgi" (it is a global setting) appcmd.exe set config -section:system.webServer/fastCgi /+"[fullPath='d:strawberryperlinperl.exe',arguments='d:wwwWebAppscriptwebapp_fastcgi.pl -e',maxInstances='4',idleTimeout='300',activityTimeout='30',requestTimeout='90',instanceMaxRequests='1000',protocol='NamedPipe',flushNamedPipe='False']" /commit:apphost Configuring proper handler (it is a site related setting) appcmd.exe set config "CatalystSite" -section:system.webServer/handlers /+"[name='CatalystFastCGI',path='*',verb='GET,HEAD,POST',modules='FastCgiModule',scriptProcessor='d:strawberryperlinperl.exe|d:wwwWebAppscriptwebapp_fastcgi.pl -e',resourceType='Unspecified',requireAccess='Script']" /commit:apphost Note: before launching the commands above, do not forget to change the site name and paths to values relevant for your server setup. AUTHORS