Sponsored Content
Top Forums UNIX for Advanced & Expert Users How to configure tape drive on SUN Post 11066 by s_aamir on Wednesday 28th of November 2001 11:42:00 AM
Old 11-28-2001
Question How to configure tape drive on SUN

I am trying to configure DAT Tape drive on SUN E220 system but I don't have SUN keyboard. I am using a tty terminal k/b.
What are my alternavtives?
Is there any way to send interupts to the system on OK prompt using tty kb for probe SCSI.

Thanks in advance.
 

10 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

Tape Drive Connected to a Sun Ultra 10/Solaris 2.7

I have a Sun Ultra 10/Solaris 2.7 with a differential SCSI card connected to a Supter DLt1 Tape Drive. When I boot the machine, and I do a probe-scsi-all in the very beginning of the boot process. It shows up correctly. If I wait for the boot process to proceed and then I do a probe-scsi-all, I get... (1 Reply)
Discussion started by: brv
1 Replies

2. Filesystems, Disks and Memory

help installing Sun 8mm unipack scsi tape drive

Hi all, please help I am stuck. I have installed a external unipack scsi tape drive. The tape drive is Exabyte Eliant 820. All I did was connected scsi cable and power it on. When issued "probe-scsi-all" command, the tape is correctly identified. However, when issued "dmesg | more" command, the... (4 Replies)
Discussion started by: dennis
4 Replies

3. UNIX for Dummies Questions & Answers

DDS-2 Sun tape drive

Hey guys, I'm trying to mount a SUN DDS-2 tape drive on a SUN Ultra 80 machine running Solaris 9. I had the SCSI drive connected at time of install, I'm very new to Solaris so I don't know if Solaris would detect the drive like that and install some form of device driver. But, what im posting... (2 Replies)
Discussion started by: kingdbag
2 Replies

4. Solaris

how to install tape drive on sun ver 5.9

hi, need your help mentors I have external SCSI tape DRIVE COmpaq 15/30 GB DLT and I dont know how to install these and how to view if it is working. I'm also have another disk taken form my old sun and I want to use these also but my problem how I able to mount. hope anyone can help me ... (9 Replies)
Discussion started by: eykyn17
9 Replies

5. AIX

How to mount internal tape drive of sun machine in AIX 5.3

Hi, Help required! How to mount internal tape drive of sun machine in AIX 5.3 (0 Replies)
Discussion started by: ashwin.krishna
0 Replies

6. Solaris

Configure New LTO-2 Tape Drive

Can I do this live? Or, do I need to do a probe-scsi-all after doing a stop/A? (10 Replies)
Discussion started by: jgordon
10 Replies

7. Solaris

configure tape drive to sun solaris 10

Hi everyone. Im new to Sun Solaris or the Unix environment. My only background is the DOS command in windows and a little bit of c++ programming. I always worked with troubleshooting hardware and software issues with windows. Now that I need to configure tape drives using sun solaris, I had... (11 Replies)
Discussion started by: graboid888
11 Replies

8. AIX

SUN StorageTek tape drive with AIX 5.1

Hi, I have recently purchase a SUN Storage Tek desktop LTO 4 HH tape drive and connected to a IBM AIX 5.1 server. The server can detect the tape device. Can someone please advice urgently. Thanks (4 Replies)
Discussion started by: Caully
4 Replies

9. Solaris

Sun E220R + HP (SCSI) LTO Ultrium Tape Drive

Hi all, this time I'd need a help from an advanced Solaris system admin :rolleyes: I attached a HP StorageWorks Ultrium 215 Tape Drives - Overview - c00059530 - HP Business Support Center to my Sun E220R and it got recognized immediately (probe-scsi-all). Now the operating system boot process... (8 Replies)
Discussion started by: pseudocoder
8 Replies

10. Solaris

Install ext DLT Sun Tape drive on V445 Solaris 10

I have a SunFire V445 running Solaris 10 and am adding a Sun DLT tape drive. From the OK prompt the probe-scsi-all does see the drive and it is the proper target of 4. When I do the boot -- -r it does build the /dev/rmt directories correctly and the links to /devices appear correct as well. When I... (8 Replies)
Discussion started by: chastings
8 Replies
fcinfo(1M)																fcinfo(1M)

NAME
fcinfo - Fibre Channel HBA Port Command Line Interface SYNOPSIS
fcinfo hba-port [-l] [HBA_port_WWN...] fcinfo remote-port [-ls] [-p HBA_port_WWN] [REMOTE_port_WWN...] fcinfo [-V] fcinfo [-?] fcinfo is a command line interface that collects administrative information on fibre channel host bus adapter (HBA) ports on a host. It also collects data on any fibre channel targets that may be connected to those ports in a Storage Area Network (SAN). SUBCOMMANDS The following subcommands are supported: hba-port Lists information for the HBA port referenced by the specified HBA_port_WWN. If HBA_port_WWN is not specified, all fibre channel HBA ports on the host will be listed. remote-port Lists the remote-port information for those remote ports that are specified. If no REMOTE_port_WWN is specified, all remote ports that are visible through HBA_port_WWN are listed. OPTIONS
The following options are supported: -l, --linkstat Lists the link error statistics information for the port referenced by the specified HBA_port_WWN or REMOTE_port_WWN. -p HBA_port_WWN, --port HBA_port_WWN Retrieve remote port information from the HBA_port_WWN of the local HBA port on the host. The -p option can only be used with the remote-port subcommand and is a mandatory option. -s, --scsi-target Lists the SCSI target information for all remote ports the user has asked for. The -p, --port option must always be specified and must be a valid HBA port on the host. This HBA port will be used as the initiator for which to retrieve the SCSI level target information. Note that this will only function on remote port fibre channel World-Wide Names that support an FC4 type of SCSI. -V, --version Prints the version information. -?, --help Prints the usage information. EXAMPLES
Example 1: Listing all HBA ports The following command lists all fibre channel HBA ports on the host: # fcinfo hba-port HBA Port WWN: 210000e08b074cb5 OS Device Name: /dev/cfg/c1 Manufacturer: QLogic Corp. Model: 375-3108-xx Type: N-port State: online Supported Speeds: 1Gb 2Gb Current Speed: 2Gb Node WWN: 200000e08b074cb5 HBA Port WWN: 210100e08b274cb5 OS Device Name: /dev/cfg/c2 Manufacturer: QLogic Corp. Model: 375-3108-xx Type: N-port State: online Supported Speeds: 1Gb 2Gb Current Speed: 2Gb Node WWN: 200100e08b274cb5 HBA Port WWN: 210000e08b072ab5 OS Device Name: /dev/cfg/c3 Manufacturer: QLogic Corp. Model: 375-3108-xx Type: L-port State: online Supported Speeds: 1Gb 2Gb Current Speed: 2Gb Node WWN: 200000e08b072ab5 HBA Port WWN: 210100e08b272ab5 OS Device Name: /dev/cfg/c4 Manufacturer: QLogic Corp. Model: 375-3108-xx Type: N-port State: online Supported Speeds: 1Gb 2Gb Current Speed: 2Gb Node WWN: 200100e08b272ab5 Example 2: Listing HBA ports and link statistics The following command lists information for the HBA ports and the link statistics for those ports: # fcinfo hba-port -l 210000e08b074cb5 210100e08b274cb5 HBA Port WWN: 210000e08b074cb5 OS Device Name: /dev/cfg/c1 Manufacturer: QLogic Corp. Model: 375-3108-xx Type: N-port State: online Supported Speeds: 1Gb 2Gb Current Speed: 2Gb Node WWN: 200000e08b074cb5 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 HBA Port WWN: 210100e08b274cb5 OS Device Name: /dev/cfg/c2 Manufacturer: QLogic Corp. Model: 375-3108-xx Type: N-port State: online Supported Speeds: 1Gb 2Gb Current Speed: 2Gb Node WWN: 200100e08b274cb5 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Example 3: Listing all remote ports The following command lists all remote ports that are visible through the given HBA port: # fcinfo remote-port -p 210100e08b274cb5 Remote Port WWN: 50020f230000b4af Active FC4 Types: SCSI SCSI Target: yes Node WWN: 50020f200000b4af Remote Port WWN: 210000e08b07daa6 Active FC4 Types: SCSI SCSI Target: no Node WWN: 200000e08b07daa6 Remote Port WWN: 20030003ba27c788 Active FC4 Types: SCSI SCSI Target: yes Node WWN: 10000003ba27c788 Remote Port WWN: 210000e08b096a60 Active FC4 Types: SCSI,IP SCSI Target: no Node WWN: 200000e08b096a60 Example 4: Listing remote ports and link statistics The following command lists information for the remote ports and the link statistics for those ports: # fcinfo remote-port -l -p 210100e08b272ab5 Remote Port WWN: 210100e08b296a60 Active FC4 Types: SCSI,IP SCSI Target: no Node WWN: 200100e08b296a60 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 20030003ba27d56d Active FC4 Types: SCSI SCSI Target: yes Node WWN: 10000003ba27d56d Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 4765165 Loss of Signal Count: 4765165 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 210100e08b27f7a6 Active FC4 Types: SCSI SCSI Target: no Node WWN: 200100e08b27f7a6 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 50020f230000b897 Active FC4 Types: SCSI SCSI Target: yes Node WWN: 50020f200000b897 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 7 Loss of Signal Count: 7 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 210100e08b27daa6 Active FC4 Types: SCSI SCSI Target: no Node WWN: 200100e08b27daa6 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 210000e08b074cb5 Active FC4 Types: SCSI,IP SCSI Target: no Node WWN: 200000e08b074cb5 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 210100e08b296060 Active FC4 Types: SCSI SCSI Target: no Node WWN: 200100e08b296060 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Example 5: Listing all SCSI targets and link statistics The following command lists all remote ports as well as the link statistics and scsi-target information: # fcinfo remote-port -sl -p 210100e08b272ab5 Remote Port WWN: 210100e08b296a60 Active FC4 Types: SCSI,IP SCSI Target: no Node WWN: 200100e08b296a60 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 20030003ba27d56d Active FC4 Types: SCSI SCSI Target: yes Node WWN: 10000003ba27d56d Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 4765165 Loss of Signal Count: 4765165 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 LUN: 0 Vendor: SUN Product: T4 OS Device Name: /dev/rdsk/c4t20030003BA27D56Dd0s2 LUN: 1 Vendor: SUN Product: T4 OS Device Name: /dev/rdsk/c4t20030003BA27D56Dd1s2 Remote Port WWN: 210100e08b27f7a6 Active FC4 Types: SCSI SCSI Target: no Node WWN: 200100e08b27f7a6 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 50020f230000b897 Active FC4 Types: SCSI SCSI Target: yes Node WWN: 50020f200000b897 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 7 Loss of Signal Count: 7 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 LUN: 0 Vendor: SUN Product: T300 OS Device Name: Unknown LUN: 1 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d1s2 LUN: 2 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d2s2 LUN: 3 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d3s2 LUN: 4 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d4s2 LUN: 5 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d5s2 LUN: 6 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d6s2 LUN: 7 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d7s2 LUN: 8 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d8s2 LUN: 9 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d9s2 LUN: 10 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d10s2 LUN: 11 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d11s2 LUN: 12 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d12s2 LUN: 13 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d13s2 LUN: 14 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d14s2 LUN: 15 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d15s2 Remote Port WWN: 210100e08b27daa6 Active FC4 Types: SCSI SCSI Target: no Node WWN: 200100e08b27daa6 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 210000e08b074cb5 Active FC4 Types: SCSI,IP SCSI Target: no Node WWN: 200000e08b074cb5 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Remote Port WWN: 210100e08b296060 Active FC4 Types: SCSI SCSI Target: no Node WWN: 200100e08b296060 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Example 6: Listing SCSI target information The following command lists all remote ports as well as the scsi-target information: # fcinfo remote-port -s -p 210100e08b272ab5 Remote Port WWN: 210100e08b296a60 Active FC4 Types: SCSI,IP SCSI Target: no Node WWN: 200100e08b296a60 Remote Port WWN: 20030003ba27d56d Active FC4 Types: SCSI SCSI Target: yes Node WWN: 10000003ba27d56d LUN: 0 Vendor: SUN Product: T4 OS Device Name: /dev/rdsk/c4t20030003BA27D56Dd0s2 LUN: 1 Vendor: SUN Product: T4 OS Device Name: /dev/rdsk/c4t20030003BA27D56Dd1s2 Remote Port WWN: 210100e08b27f7a6 Active FC4 Types: SCSI SCSI Target: no Node WWN: 200100e08b27f7a6 Remote Port WWN: 50020f230000b897 Active FC4 Types: SCSI SCSI Target: yes Node WWN: 50020f200000b897 LUN: 0 Vendor: SUN Product: T300 OS Device Name: Unknown LUN: 1 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d1s2 LUN: 2 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d2s2 LUN: 3 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d3s2 LUN: 4 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d4s2 LUN: 5 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d5s2 LUN: 6 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d6s2 LUN: 7 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d7s2 LUN: 8 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d8s2 LUN: 9 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d9s2 LUN: 10 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d10s2 LUN: 11 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d11s2 LUN: 12 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d12s2 LUN: 13 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d13s2 LUN: 14 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d14s2 LUN: 15 Vendor: SUN Product: T300 OS Device Name: /dev/rdsk/c4t50020F230000B897d15s2 Remote Port WWN: 210100e08b27daa6 Active FC4 Types: SCSI SCSI Target: no Node WWN: 200100e08b27daa6 Remote Port WWN: 210000e08b074cb5 Active FC4 Types: SCSI,IP SCSI Target: no Node WWN: 200000e08b074cb5 Remote Port WWN: 210100e08b296060 Active FC4 Types: SCSI SCSI Target: no Node WWN: 200100e08b296060 See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNW | +-----------------------------+-----------------------------+ |Interface Stability |Evolving | +-----------------------------+-----------------------------+ attributes(5) ERROR MESSAGES
Errors that can occur in addition to the errors normally associated with system administration commands: HBA_port_WWN: not found REMOTE_port_WWN: not found 17 Feb 2005 fcinfo(1M)
All times are GMT -4. The time now is 07:46 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy