Sponsored Content
Full Discussion: ioscan
Operating Systems HP-UX ioscan Post 10986 by jennifer on Tuesday 27th of November 2001 12:49:11 AM
Old 11-27-2001
ioscan

Hi,

what is the difference in these two commands/

#ioscan -funC disk

#ioscan -knfC disk

To me both the commands produce the same information.

regards
jenniferSmilie
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

ioscan

Hi, I am looking for a similar 'ioscan' command in solaris 2.7. Is there any ? (5 Replies)
Discussion started by: guest100
5 Replies

2. What is on Your Mind?

IOSCAN Command

I need to know what is the differance between ioscan comand and search command ,in addition I search in your site for more details on ioscan command but I found nothing. (1 Reply)
Discussion started by: Kaswara
1 Replies

3. Solaris

SUN Solaris "ioscan"

Hi, What is the equivelent command for ioscan from HP in SUN, i.e I need to display all hardware devies with path/driver/stats etc. regards, Ahmed (2 Replies)
Discussion started by: Ahmad
2 Replies

4. HP-UX

Question about UNIX ioscan command

Hello there. I have a question regarding the ioscan commnad. When you execute the line ioscan -fnC processor it outputs a list of all processors in the machine. Does this list displays only physical CPUs or does it displays each core? For example, if i have a server with 1 Dual Core... (10 Replies)
Discussion started by: Spilson
10 Replies

5. HP-UX

ioscan on HP-UX 9.1

I am trying to work out the logical device name on a HP 9000 system running HP-UX 9.1. I see that ioscan-fnC disk looks like the command on later versions of HP-UX unfortunately it seems the n option is not available on 9.1. The output from ioscan -fC disk is:- Class H/W Path Driver H/W... (3 Replies)
Discussion started by: malcqv
3 Replies

6. Solaris

Solaris equivalent of the ioscan command

What is the Solaris equivalent of the HP-UX "ioscan -funC" command which lists all hardware on the system? (5 Replies)
Discussion started by: etc
5 Replies

7. Solaris

How to solve "ioscan -En" hardware errors

Hi, I found devices errors in #ioscan -En. it is showing that soft errors = 0 and hard errors= 5. what should i do for hard errors=0. Thanks. (4 Replies)
Discussion started by: arjunreddy3
4 Replies

8. HP-UX

ioscan command

Hi all ! I'm a newbie in HP-Unix . In HP-Unix ,'ioscan' command is used to scan I/O system but I don't know what the 'ioscan' command is in Linux/Unix ? I cannot find it in Linux/Unix OS . Thanks (2 Replies)
Discussion started by: nemoflich
2 Replies

9. Solaris

ioscan -En how to exclude tapes?

i would like to list all disks, but this command with these options list tapes too. i donīt find out an option which list only the class like ioscan in hp-ux. could anybody help me? thanks a lot. (2 Replies)
Discussion started by: pabloli150
2 Replies
ifc_disable_mgmt_lun(5) 					File Formats Manual					   ifc_disable_mgmt_lun(5)

NAME
ifc_disable_mgmt_lun - select whether or not management luns are discovered in the legacy representation of mass storage devices VALUES
Failsafe Default Allowed values Enable discovery of management luns for array devices. Disable discovery of management luns for array devices. Recommended values DESCRIPTION
Management luns provide the means to access the control ports of Fibre Channel disk arrays. They are represented in both the legacy and the agile view of storage devices. The legacy representation of a management lun is typically created under a separate virtual extension bus node. The entry for a legacy management lun looks like this: On a system with a large number of storage devices connected, creation of management luns can result in an insufficient number of virtual extension buses for the legacy representation of data luns. Since the number of extension buses on a system is limited to 256, luns requiring virtual extension buses above 256 will be unusable through legacy device special files. Disabling the discovery and creation of management luns will free up virtual extension buses for use by data luns. Who Is Expected to Change This Tunable? System administrators who expect to use a large number of storage devices requiring more than 256 extension buses through legacy device special files. Restrictions on Changing Changes to this tunable take effect immediately. However, existing management luns will not be removed. When Should the Tunable Be Turned On? This tunable should be turned on when the system runs out of extension buses for configuring the legacy representation of data luns. What Are the Side Effects of Turning the Tunable Off? None. When Should the Tunable Be Turned Off? When the functionality provided by the management luns is desired. What Are the Side Effects of Turning the Tunable On? Existing management luns in the legacy representation will show up in the state. What Other Tunables Should Be Changed at the Same Time? None. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by HP. SEE ALSO
ioinit(1M), ioscan(1M), kctune(1M). Tunable Kernel Parameters ifc_disable_mgmt_lun(5)
All times are GMT -4. The time now is 08:19 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.