11-17-2001
If you've already checked your cables
and ran fsck and got lots of errors,
then YES I agree. You probably should
replace the disk.
Sorry.
9 More Discussions You Might Find Interesting
1. Filesystems, Disks and Memory
I was using an external SCSI disk on a Sun Ultra60 (Solaris 7) as the boot device. It was labelled c1t0d0. I then moved it into the internal removable mounts and it should become c0t0d0, but it apparently didn't change properly. When the machine boots, it gets host information from the disk... (2 Replies)
Discussion started by: Solaris
2 Replies
2. UNIX for Dummies Questions & Answers
I have installed perc 2 raid card .in installiation , one is install whole for unix file system,and other select "do not modify"
after installiation ,how to use another ? add filesystem ?how to? (2 Replies)
Discussion started by: luckylwf
2 Replies
3. Filesystems, Disks and Memory
Is there a way to determine the number of available spare sectors on a disk ? as it may be useful for notifying a user to take a backup of the disk before it runs into a medium error. (6 Replies)
Discussion started by: rednex
6 Replies
4. UNIX for Advanced & Expert Users
how can i determine what disks are scsi disks from the format command? (5 Replies)
Discussion started by: rcon1
5 Replies
5. AIX
hi, i removed a FC disk (it has a single VG on it) from a AIX 6.1 server and exported it to another AIX server. after doing cfgmgr -v .. the disk showed up in the second AIX 6.1 server. Now how can i see the data which is on the disk from the second AIX server. (5 Replies)
Discussion started by: navadeep
5 Replies
6. UNIX for Advanced & Expert Users
I was wondering if anyone knew of any tools that would identify generic scsi disks on servers running AIX 5.3? Going through diag into the hot plugs does not work. I know it used to for 4.3 on some servers I managed with generic scsi but for some reason I either dont the option to choose a disk... (2 Replies)
Discussion started by: plcj58
2 Replies
7. Solaris
Hi Gurus,
I need help. Mine is an Ultra 10 machine running on solaris 7. Problem with solaris 7 is, it can no longer recognize IDE disks greater that 10GB. My workaround is ro use an external SCSI disk since it is recognizable with solaris 7. I backup my filesystems (residing on the IDE... (2 Replies)
Discussion started by: domesat
2 Replies
8. SCO
i was installing i my computer windows xp and sco
when i use knoppix5.0 live to read scsi partition wish sco was installing
show me message that i have not permission to acces in scsi hard drive
help me please (1 Reply)
Discussion started by: walidfinder
1 Replies
9. Solaris
Hi.
I need to boot on Sun Blade 150 from scsi-disk, that ran on old Sun Ultra 10.
It is necessary to take some the information from an old disk and something to study.
The workstation is booted and I receive the following issue::mad:
Sun Blade 150 (UltraSPARC-IIe 650MHz), No Keyboard (tip... (3 Replies)
Discussion started by: wolfgang
3 Replies
LEARN ABOUT FREEBSD
systemd-fsck
SYSTEMD-FSCK@.SERVICE(8) systemd-fsck@.service SYSTEMD-FSCK@.SERVICE(8)
NAME
systemd-fsck@.service, systemd-fsck-root.service, systemd-fsck - File system checker logic
SYNOPSIS
systemd-fsck@.service
systemd-fsck-root.service
/lib/systemd/systemd-fsck
DESCRIPTION
systemd-fsck@.service and systemd-fsck-root.service are services responsible for file system checks. They are instantiated for each device
that is configured for file system checking. systemd-fsck-root.service is responsible for file system checks on the root file system, but
only if the root filesystem was not checked in the initramfs. systemd-fsck@.service is used for all other file systems and for the root
file system in the initramfs.
These services are started at boot if passno in /etc/fstab for the file system is set to a value greater than zero. The file system check
for root is performed before the other file systems. Other file systems may be checked in parallel, except when they are on the same
rotating disk.
systemd-fsck does not know any details about specific filesystems, and simply executes file system checkers specific to each filesystem
type (/sbin/fsck.*). This helper will decide if the filesystem should actually be checked based on the time since last check, number of
mounts, unclean unmount, etc.
If a file system check fails for a service without nofail, emergency mode is activated, by isolating to emergency.target.
KERNEL COMMAND LINE
systemd-fsck understands these kernel command line parameters:
fsck.mode=
One of "auto", "force", "skip". Controls the mode of operation. The default is "auto", and ensures that file system checks are done
when the file system checker deems them necessary. "force" unconditionally results in full file system checks. "skip" skips any file
system checks.
fsck.repair=
One of "preen", "yes", "no". Controls the mode of operation. The default is "preen", and will automatically repair problems that can be
safely fixed. "yes" will answer yes to all questions by fsck and "no" will answer no to all questions.
SEE ALSO
systemd(1), fsck(8), systemd-quotacheck.service(8), fsck.btrfs(8), fsck.cramfs(8), fsck.ext4(8), fsck.fat(8), fsck.hfsplus(8),
fsck.minix(8), fsck.ntfs(8), fsck.xfs(8)
systemd 237 SYSTEMD-FSCK@.SERVICE(8)