optiups(8) [freebsd man page]

OPTIUPS(8)							    NUT Manual								OPTIUPS(8)

NAME
optiups - Driver for Opti-UPS (Viewsonic) UPS and Zinto D (ONLINE-USV) equipment NOTE
This man page only documents the hardware-specific features of the optiups driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
optiups was originally written against a PowerES 280es in nut-0.45. It was revised for nut-2.0.1 and tested against a PowerES 420E. It is expected to work with at least the PowerES, PowerPS, and PowerVS models. This driver additionally supports a Zinto D from ONLINE USV-Systeme AG because of their very similar commands, but it is unknown if it also works with other UPS from them. This driver will not work with the PowerES stock serial cable. You will need to construct your own three conductor cable: UPS 6 -> PC 3 UPS 9 -> PC 2 UPS 4 -> PC 5 The cable for Online-USV uses pin UPS 7 (not UPS 4) -> PC 5. EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5) file: status_only Only poll for critical status information. Without this, optiups (and all NUT drivers) poll all sorts of information from the UPS fairly often. It is probably not often enough to hurt anything, so this option probably is not very useful, unless you have a flaky serial connection or a highly loaded machine. nowarn_noimp Does not print warnings when the UPS reports that a variable is not implemented or not pollable. Without the option you will get a message sent to your system logs each time NUT polls the UPS. If you specify nowarn_noimp, this message will only be logged once. fake_lowbatt This forces the low battery flag true. Without it, if you want to test your UPS, you will have to unplug it and wait until the battery drops to a low/critical voltage level before NUT will respond and power down your system. With the flag, NUT should power down the system soon after you pull the plug. When you are done testing, you should remove this flag. For basic shutdown configuration testing, the command upsmon -c fsd is preferred. powerup Zinto D from ONLINE-USV cannot be identified when switched to standby. Set this flag to allow the driver to power-up your Zinto UPS. This will also power-up your equipment connected to the UPS! BUGS
On the 420E, ups.serial and ups.temperature are unsupported features. This is not a bug in NUT or the NUT driver, just the way things are with this UPS. AUTHOR
Russell Kroll, Scott Heavner, Matthias Goebl SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 OPTIUPS(8)

Check Out this Related Man Page

BESTUPS(8)						      Network UPS Tools (NUT)							BESTUPS(8)

NAME
bestups - Driver for Best Power / SOLA (Phoenixtec protocol) UPS equipment NOTE
This man page only documents the hardware-specific features of the bestups driver. For information about the core driver, see nutups- drv(8). SUPPORTED HARDWARE
bestups was designed to monitor Best Power UPS hardware like the Fortress, Fortress Telecom, and Patriot Pro. It also recognizes and sup- ports SOLA units such as the 520 and 620. Other UPS hardware using the Phoenixtec protocol should also work, but they will generate a warning since their battery information is not known. This driver does not support some older Best/SOLA units. Try the bestfort driver if this one does not detect your UPS. EXTRA ARGUMENTS
This driver does not support any extra settings in the ups.conf(5). BUGS
The battery percentage is derived from the voltage data that the UPS returns, since the UPS doesn't return that value directly. On some hardware, the charge will remain at 100% for a long time and then drops quickly shortly before the battery runs out. You can confirm from the BATTVOLT readings that this is a problem with the UPS and not this driver. Similarly, the float from the charger in some models forces the battery charge percentage back up to 100% immedately after the UPS goes back on-line, so you can't tell when it is really recharged. Finally, some models give one value for the battery's nominal voltage and yet actually have a nominal voltage slightly below that. This leads to things such as the perpetual 98.7% charge on the author's Fortress 750, even when it's been charging for weeks. AUTHOR
Russell Kroll SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.exploits.org/nut/ NUT mailing list archives and information: http://lists.exploits.org/ Tue Jul 30 2002 BESTUPS(8)