Check hardware


 
Thread Tools Search this Thread
Operating Systems HP-UX Check hardware
# 1  
Old 12-25-2014
Check hardware

Hi,

I have HP-UX version 11.23. Yesterday i saw error on syslog show Ultra SCSI 320 have issue.

This rx3600 connect to EVA. How to check how many LUN connected and the connectivity to EVA?

I suspect on board controller at rx3600 have a problem. The disk on local not show amber light. Please assist me.

Thanks.
Login or Register to Ask a Question

Previous Thread | Next Thread

10 More Discussions You Might Find Interesting

1. Solaris

Check Hardware compatibility via LIVE CD

Hi Can i use Solaris LIVE CD to verify that ubuntu has all drivers present for a certain desktop PC? which Live CD should i use ? there any many varities out there Before i purchase this expensive PC i want to ensure Solairs has all drivers for it. Specs are : Processor Intel Core i7... (1 Reply)
Discussion started by: kashif_islam
1 Replies

2. Shell Programming and Scripting

Perl code to check date and check files in particular dir

Hi Experts, I am checking how to get day in Perl. If it is “Monday” I need to process…below is the pseudo code. Can you please prove the code for below condition. if (today=="Monday" ) { while (current_time LESS THAN 9:01 AM) ... (1 Reply)
Discussion started by: ajaypatil_am
1 Replies

3. Solaris

Hardware faulty, but which hardware?

Hi folk, I have this hardware faunty message, but dont know which hardware is this ? can you guide me ? --------------- ------------------------------------ -------------- --------- TIME EVENT-ID MSG-ID SEVERITY ---------------... (9 Replies)
Discussion started by: dehetoxic
9 Replies

4. Solaris

how to check for hardware layered raid in solaris 10 ?

hi all, will command metastats tell whether there is hardware layered raid ? i intend to do patching and plug out one of the disks in case the one inside encountered issues. (1 Reply)
Discussion started by: Exposure
1 Replies

5. UNIX for Dummies Questions & Answers

How to check hardware data compression

Hi, I'm looking to check the compression ratio applied by hardware to work out how much free space we have on tapes. mt -f /dev/rmt0 status shows: If I add up the output of the du command and what we backup from the script, it gives me the total space we tape up. So the plan was to find the... (4 Replies)
Discussion started by: rab
4 Replies

6. UNIX for Advanced & Expert Users

check external hardware connected to linux/solaris machines

hello, I'm planning to do inventory of all our servers but this time it's more on physical. Meaning I would like to check all hardware connected to it (external only like storage, power support) including the count Would like to get perhaps its serial nr..(linux and solaris different servers... (2 Replies)
Discussion started by: lhareigh890
2 Replies

7. UNIX for Advanced & Expert Users

Check EOF char in Unix. OR To check file has been received completely from a remote system

Advance Thanks. (1) I would like to know any unix/Linux command to check EOF char in a file. (2) Or Any way I can check a file has been reached completely at machine B from machine A. Note that machine A ftp/scp the file to machine B at unknown time. (5 Replies)
Discussion started by: alexalex1
5 Replies

8. Windows & DOS: Issues & Discussions

How To Check Hardware RAID On Windows and Linux

Hello, I have Win NT server running and I want to know how can I get Hardware RAID settings without rebooting the server? Thanks in advance. (2 Replies)
Discussion started by: sureshcisco
2 Replies

9. UNIX for Dummies Questions & Answers

Script to check for a file, check for 2hrs. then quit

I wish to seach a Dir for a specific file, once the file is found i will perform additional logic. If the file is not found within two hours, i would like to exit. Logically, I'm looking for the best way to approach this Thanks for any assistance in advance. Note: I'm using a C shell and... (2 Replies)
Discussion started by: mmarsh
2 Replies

10. Solaris

What command to check system hardware

What command can I run on a Solaris 8 server to check the hardware (ie number of processors, speed of processors, installed memory etc). (4 Replies)
Discussion started by: soliberus
4 Replies
Login or Register to Ask a Question
format(1M)																format(1M)

NAME
format - format an HP SCSI disk array LUN SYNOPSIS
device_file DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format, in which the controller writes zeroes to the data area and parity area, if any, of the LUN. NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol- lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows: 1. The controller received a Mode Select command which requires a drive sector size change. 2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03). 3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives will be formatted. 4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set. RETURN VALUE
returns the following values: 0 Successful completion. -1 Command failed. DIAGNOSTICS AND ERRORS
Errors can originate from problems with: o o SCSI (device level) communications o system calls Error messages generated by format: An error in command syntax has occurred. Enter command again with all required arguments, in the order shown. To ensure that does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)). The LUN number, which is derived from the device file name, is out of range. The addressed LUN is not configured, and thus is not known to the array controller. Utilities must be able to open the device file for raw access. The device being addressed is not an HP SCSI disk array. SCSI (device level) communication errors: Sense data associated with the failed operation is printed. Error messages generated by system calls: uses the following system calls: and Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not alter the value of The interpretation of for printing purposes is performed by the system utility EXAMPLES
To format the HP SCSI disk array LUN on a Series 800: WARNING
The command will destroy all user data on the addressed LUN. DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X. The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X. AUTHOR
was developed by HP. format(1M)