12-26-2005
HPUX Hardware commands.
HI ALL,
I am new tp HPUX and i am looking for command that will retive me the following information on HPUX:
Chassis Name & Serial Number:
Monitor
Name
BIOS
Name
EthernetPort
Name
IPEndpoint
Name
PointingDevice
Name
Keyboard
NetworkPrinter
Name
LocalPrinter
Please , please please help me with these commands....
Thanks in advance
VK
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hello, i have to activate a network interface. for HPUX1100 i can command ifconfig lanx plumb.
Why doesent it works under HPUX10.20?
How can i realise it?
thanks for your help!:) (2 Replies)
Discussion started by: ortsvorsteher
2 Replies
2. HP-UX
Hi guys,
Need a favour or information on how to get it done in configuring a HPUX-11i box?I need the commands which is needed to configure the box...The pdf's in HP site is too much to look at.Is there any advice from u guys on how could i settle this problem? (7 Replies)
Discussion started by: giriplug
7 Replies
3. AIX
Hi All,
Needed commands to find Monitor , chassis & keyboard related information on AIX.
Please please please help.
Thanks
VK (2 Replies)
Discussion started by: Veenak15
2 Replies
4. HP-UX
Hi All
Please somebody send me list of admin commands used for HPUX.
Thanks
Sunanda (2 Replies)
Discussion started by: sunanda
2 Replies
5. Solaris
Hi all
Got another strange one. If I try to enquire about the hardware, the command hangs implying Ive got a hardware issue. So, if I execute :-
iostat -en
sysdef - ( stops at the devices part )
format
cfgadm -al
Anything that searches the devices, then the command hangs.
... (4 Replies)
Discussion started by: sbk1972
4 Replies
6. HP-UX
I am new for HPUX OS and want to pursue my career in HPUX Administration.
I could not able to get following information from HP.com site, that why I need an assistance to know that - can I install HPUX 11i V3 OS on old HP B2000 & B1000 workstations (these workstation are 4 to 5 year old) or not,... (5 Replies)
Discussion started by: girish.batra
5 Replies
7. Solaris
Hi guru
I want to know which company's hardware is more stable means in term of H/W faults or replacement, in case of IBM (AIX), HP (HPUX) & SUN MICROSYSTEM (Solaris) & which order also, if we go through more stable to less stable system.
Regards (1 Reply)
Discussion started by: girish.batra
1 Replies
8. Hardware
Are there any other useful hardware commands to get information about your hardware? Is there any information that can't be found with these commands?
cat /proc/cpuinfo
cat /proc/meminfo
dmesg
lspci
sudo dmidecode
cpuid | more
lspci -v | grep VGA
sudo lspci -v -s 00:02.0
sudo lspci -vvv... (12 Replies)
Discussion started by: cokedude
12 Replies
9. HP-UX
We would like to know a HP Utility or any Unix command that can give the exact status of PCI Gigabit Ethernet cable (lan cable) We had tried to execute
lanscan
ioscan -fnC lan
The status appears to be the same when the cable is plugged & unplugged and also when the lan is disabled &... (5 Replies)
Discussion started by: siva3492
5 Replies
10. HP-UX
I own a 1999 vintage HP Logic Analyzer that runs HPUX 10.20. It is a 9000/775/rock system similar to a Visualize C132L/160L system.
I'm attempting, mostly for the fun of it, to upgrade the existing slow 5MB/s-only SCSI system, with a new-er PCI card. Of course drivers is my major concern. I'd... (2 Replies)
Discussion started by: KeithM
2 Replies
LEARN ABOUT SUSE
hpialarms
hpialarms(1) OpenHPI hpialarms(1)
NAME
hpialarms - A openhpi sample application that shows "Alarm Control" management instruments
SYNOPSIS
hpialarms [-a -b -c -i -m -n -p -o -x]
DESCRIPTION
hpialarms walks the RPT (Resource Present Table) for resouces that have "Alarm Control" management instruments (SAHPI_CTRL_LED).
OPTIONS
-c1 sets Critical Alarm on
-c0 sets Critical Alarm off
-m1 sets Major Alarm on
-m0 sets Major Alarm off
-n1 sets Minor Alarm on
-n0 sets Minor Alarm off
-p1 sets Power Alarm on
-p0 sets Power Alarm off
-i5 sets Chassis ID on for 5 sec
-i0 sets Chassis ID off
-a1 sets Disk A fault on
-a0 sets Disk A fault off
-b1 sets Disk B fault on
-b0 sets Disk B fault off
-d[byte] sets raw Alarm byte
-o sets all Alarms off
-x show eXtra debug messages
SAMPLE OUTPUT
hpialarmpanel ver 0.6
RptInfo: UpdateCount = 5, UpdateTime = 8a2dc6c0
rptentry[0] resourceid=1 tag: Mullins
RDR[45]: ctltype=2:1 oem=0 Chassis Identify Control
RDR[48]: ctltype=0:1 oem=10 Front Panel Power Alarm LED state = off
RDR[51]: ctltype=0:1 oem=13 Front Panel Minor Alarm LED state = ON
RDR[46]: ctltype=0:0 oem=0 Cold Reset Control
RDR[49]: ctltype=0:1 oem=11 Front Panel Critical Alarm LED state = off
RDR[50]: ctltype=0:1 oem=12 Front Panel Major Alarm LED state = off
SEE ALSO
AUTHORS
Authors of this man page:
Peter D Phan (pdphan@users.sourceforge.net)