Good point - the meta device driver must know that the disk has failed.
The safest method is to simply pull out the physical disk,
and read from that metadevice until metastat shows that the device has failed.
Then insert the new physical disk, and run
in your case ---------- Post updated at 05:24 AM ---------- Previous update was at 05:22 AM ----------
Please first check with
If the failed device has got a metadb, it must be recreated before a metareplace.
Hi Friends,
Can any of you explain me about the below line of code?
mn_code=`env|grep "..mn"|awk -F"=" '{print $2}'`
Im not able to understand, what exactly it is doing :confused:
Any help would be useful for me.
Lokesha (4 Replies)
Hello,
I'm brand new to Sun/Solaris.
I have a Sun Blade 150, with SunOS 5.8.
I wanted to make a backup to prevent future data loss, so I put the disk in a normal PC with Windows XP to try to make a backup with Norton Ghost, the disk was detected, but not the file volume, so I place the disk... (6 Replies)
Hi,
I have line in input file as below:
3G_CENTRAL;INDONESIA_(M)_TELKOMSEL;SPECIAL_WORLD_GRP_7_FA_2_TELKOMSEL
My expected output for line in the file must be :
"1-Radon1-cMOC_deg"|"LDIndex"|"3G_CENTRAL|INDONESIA_(M)_TELKOMSEL"|LAST|"SPECIAL_WORLD_GRP_7_FA_2_TELKOMSEL"
Can someone... (7 Replies)
Hi all,
I have this text file containing 9 columns separated by space. The 8th columns contains the numbers.
C1 C2 C3 C4 C5 C6 C7 C8 C9
er rt yt gh iu nk il 0.07 xs
yt lr ty bg iu zk nh 0,0005 lt
...etc.
I want to replace the comma with full stop only in 8th coloumn.
the output... (8 Replies)
Hello,
I am supposed to check the RAID health of a system but when I type metastat it says "there are no existing databases"
Does this mean that there is no RAID configured at all? Is there any other utility I should try?
I know the system has two disks.
Tanks! (8 Replies)
How to use "mailx" command to do e-mail reading the input file containing email address, where column 1 has name and column 2 containing “To” e-mail address
and column 3 contains “cc” e-mail address to include with same email.
Sample input file, email.txt
Below is an sample code where... (2 Replies)
Hello.
System : opensuse leap 42.3
I have a bash script that build a text file.
I would like the last command doing :
print_cmd -o page-left=43 -o page-right=22 -o page-top=28 -o page-bottom=43 -o font=LatinModernMono12:regular:9 some_file.txt
where :
print_cmd ::= some printing... (1 Reply)
Discussion started by: jcdole
1 Replies
LEARN ABOUT LINUX
iir
IIR(4) BSD Kernel Interfaces Manual IIR(4)NAME
iir -- Intel Integrated RAID controller and ICP Vortex driver
SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file:
device pci
device scbus
device iir
Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5):
iir_load="YES"
DESCRIPTION
The iir driver claims to interface with the Intel integrated RAID controller cards, and all versions of the ICP Vortex controllers (including
FC).
HARDWARE
Controllers supported by the iir driver include:
o Intel RAID Controller SRCMR
o Intel Server RAID Controller U3-l (SRCU31a)
o Intel Server RAID Controller U3-1L (SRCU31La)
o Intel Server RAID Controller U3-2 (SRCU32)
o All past and future releases of Intel and ICP RAID Controllers.
o Intel RAID Controller SRCU21 (discontinued)
o Intel RAID Controller SRCU31 (older revision, not compatible)
o Intel RAID Controller SRCU31L (older revision, not compatible)
The SRCU31 and SRCU31L can be updated via a firmware update available from Intel.
SEE ALSO cam(4), pass(4), xpt(4), camcontrol(8)AUTHORS
The iir driver is supported and maintained by Achim Leubner <Achim_Leubner@adaptec.com>.
This manual page was written by Tom Rhodes <trhodes@FreeBSD.org> and is based on information supplied by the driver authors and the website
of Mike Smith <msmith@FreeBSD.org>.
BSD August 8, 2004 BSD