Sponsored Content
The Lounge War Stories How not to install fibre links between data centres! Post 302692453 by admin_xor on Monday 27th of August 2012 04:32:12 PM
Old 08-27-2012
"Innovative Fix" Smilie
 

7 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

How to install FreeBSD without loosing my data?

hi. I am newbie in Unix. I wanted to install Free BSD 5.2.1 to my computer which winXp was already installed. But i couldn't. I chose Standard. Then it said you are going to use dos style fdisk partitioning. Then a window displayed begining like this. WARNING: A geometry of 155127/16/63 for... (0 Replies)
Discussion started by: sualcavab
0 Replies

2. Shell Programming and Scripting

4 x fibre cards elimination

Hi, I have variables like mentioned below and want to separate as mentioned in output. var1="4 x fibre cards" var2="2 fibre cards" var3="6 - fibre cards" var4="4 x dual-port" I have variables like this.I want to separate numbers from this and fibre cards from this. output has to be... (4 Replies)
Discussion started by: ajilesh
4 Replies

3. AIX

Install Fibre Card AIX 5.3

Hello, I have two systems that are being prepared to be SAN attached .. can anyone tell me any specific checks I should perform prior to the cards being installed... I am aware of firmware / OS level and relevant drivers, is there anything else? thanks Chris. (8 Replies)
Discussion started by: chlawren
8 Replies

4. Solaris

Hard Links and Soft or Sym links

When loooking at files in a directory using ls, how can I tell if I have a hard link or soft link? (11 Replies)
Discussion started by: Harleyrci
11 Replies

5. AIX

List all the soft links and hard links

Hi I'm logged in as root in an aix box Which command will list all the soft links and hard links present in the server ? (2 Replies)
Discussion started by: newtoaixos
2 Replies

6. Hardware

Fibre Channel HBA recommendations?

We will be buying new Xeon E5-based servers for our datacenter and were wondering which Fibre Channel host bus adapters we should select for these. The choices are Emulex or QLogic (8Gb FC HBAs). Anybody have any recommendations on which is the better choice? Thanks in advance. (1 Reply)
Discussion started by: atahmass
1 Replies

7. AIX

VIOS - fibre adapters not seeing luns

Hi guys, I've been trying to tackle this issue for days and I'm stumped. Hopefully someone can give more light on what else I can do. I have a p7 series box, with dual VIOS and 10 lpars and everything was working fine until I had to move the box to another location in the data centre. Ensured... (16 Replies)
Discussion started by: aixkidbee
16 Replies
mcwarp(1)					       The Computational Morphometry Toolkit						 mcwarp(1)

NAME
mcwarp - Multi-channel nonrigid registration SYNOPSIS
mcwarp [options] mcaffineOutput DESCRIPTION
Multi-channel nonrigid B-spline image registration using histogram-based or covariance-based joint entropy measures OPTIONS
Global Toolkit Options (these are shared by all CMTK tools) --help Write list of basic command line options to standard output. --help-all Write complete list of basic and advanced command line options to standard output. --wiki Write list of command line options to standard output in MediaWiki markup. --man Write man page source in 'nroff' markup to standard output. --version Write toolkit version to standard output. --echo Write the current command line to standard output. --verbose-level <integer> Set verbosity level. --verbose, -v Increment verbosity level by 1 (deprecated; supported for backward compatibility). --threads <integer> Set maximum number of parallel threads (for POSIX threads and OpenMP). Main Options --out-archive <string>, -o <string> Output archive path. [Default: NONE] --downsample-from <integer>, -d <integer> Initial downsampling factor [1]. [Default: 1] --downsample-to <integer>, -D <integer> Final downsampling factor [1]. [Default: 1] --downsample-average <boolean> Downsample using sliding-window averaging [default: off] ) [Default: 0] --smooth <float> Sigma of Gaussian smoothing kernel in multiples of template image pixel size [default: off] ) [Default: 0] --grid-spacing <double> Initial control point grid spacing in mm. [Default: 40] --grid-spacing-exact <double> Exact initial grid spacing, even if it doesn't match image FOV. [Default: disabled] --refine-grid <integer> Number of control point grid refinements. [Default: 0] --delay-refine-grid Delay control point grid refinement until after pixel refinement. --adaptive-fix-thresh-factor <float> Intensity threshold factor [0..1] for adaptive parameter fixing. [default: 0 -- no fixing] [Default: 0] --adaptive-fix-thresh-factor-entropy <float> Entropy threshold factor [0..1] for adaptive parameter fixing. [default: 0 -- no fixing] [Default: disabled] --fix-warp-x Fix transformation (do not warp) in x-direction. --fix-warp-y Fix transformation (do not warp) in y-direction. --fix-warp-z Fix transformation (do not warp) in z-direction. --jacobian-constraint-weight <float> Weight for Jacobian volume preservation constraint [Default: 0] --histograms, -H Use multi-dimensional histograms to compute entropies [default. [This is the default] --covariance, -C Use covariance matrix determinants to compute entropies. --cubic, -c Use cubic interpolation [default: linear] --mi Use standard mutual information metric [default] [This is the default] --nmi Use normalized mutual information metric --intensity-correction, -I Correct image intensities using local transformation Jacobian to preserve total signal --initial-step-size <double> Initial optimizer step size in pixels. [Default: 1] --final-step-size <double> Initial optimizer step size in pixels. [Default: 0.125] --delta-f-threshold <double> Optional threshold to terminate optimization (level) if relative change of target function drops below this value. [Default: 0] AUTHORS
Torsten Rohlfing, with contributions from Michael P. Hasak, Greg Jefferis, Calvin R. Maurer, and Daniel B. Russakoff LICENSE
http://www.fsf.org/licensing/licenses/gpl.html BUGS
Report bugs at http://nitrc.org/projects/cmtk/ ACKNOWLEDGMENTS
From April 2009 through September 2011, CMTK Development and Maintenance was supported by the National Institute of Biomedical Imaging and Bioengineering under Grant No.R01 EB008381 (PI: Torsten Rohlfing). CMTK 2.2.2 Jul 20 2012 mcwarp(1)
All times are GMT -4. The time now is 11:25 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy