Hello,
Iam having problems getting more then one ip to work here is my setup!
Hostname: nexus
NIC: e000g1
(example ips)
My ips 80.80.80.15 to 80.80.80.20
Defaultrouter 80.80.80.1
nameservers 80.80.80.100 and 80.80.80.200
How would i do this? Any help would be mutch appriciated!... (7 Replies)
hello people
i hope you can please help me.
i have a server and several ip-addresses pointing to it.
now i want
a) that the server can be reached on all ip adresses from the internet
b) that i can access the internet from the server and decide which IP-address is being used ( i can... (4 Replies)
Alo
I have a file with a lot of addresses where I want to list unique addresses and the number of theirs occurrence.
I have this input file:
0011bd09 ea 01 0b 04 ea 01 0b 38-bd 11 00 98 15 cb 01 00 .......8........
0011bd09 ea 11 00 98 15 cb 01 00-00 00 00 d8 3d 8d 01 94 ... (5 Replies)
Hi,
I have a problem when running some tests.
I unplug one power cable from the server.
No message is sent to/var/adm/messages
On the ILOM GUI, it shows power state deasserted.
Anyone knows how to forward this message to the OS, perhaps using the alert management settings? IPMI,snmp?... (1 Reply)
Hi Everyone.
What is the differece b/n ALOM and ALOM CMT Service processor.
I am trying reset ALOM login/passwd using scadm utility on T2000, while I am googling I came cross ALOM CMT doesnt support scadm utility, but ALOM supports.
Not sure how different are these.
Thanks, (0 Replies)
Hi gurus,
I have a sun netra 240 server. I want to get to the ALOM but it always ask for login and password. Can anyone tell me how I can reset the ALOM it to default so I can be able to configure it?
Thanks lots. (2 Replies)
Hi all,
I have a list of IP addresses in a column in a text file name ipaddress.txt
192.168.0.1
192.168.0.2
192.168.0.5
192.168.0.4
192.168.0.5
I would like to convert ipaddress.txt to have the following thing :
192.168.0.1, 192.168.0.2, 192.168.0.3,192.168.0.4,192.168.0.5
I know... (4 Replies)
Hi,
How to set ip address on eth0 for access ssh from ALOM? Is it possible? Now i cannot access it because don't have VGA.
I keep try to access using ssh. Please guide me.
Thanks. (16 Replies)
Hi all,
I have some problems with the fan FT0.F0, which looks like has a problem with the PROM/ALOM ( I am nor sure who).....but, in fact, the fan is working properly even in other V440 Sparc Server.
We checked HW comunication between Fan and the MotherBoard, and we think is a problem of... (8 Replies)
Discussion started by: proof_enrique
8 Replies
LEARN ABOUT CENTOS
solterm
solterm(1) IPMI Serial over LAN program solterm(1)NAME
solterm - An IPMI Serial over LAN program
SYNOPSIS
solterm
<connection parms> [-e escape_char] [-notencrypted] [-notauthenticated] [-bitrate (9600|19200|38400|57600|115200)] [-alerts (suc-
ceed|defer|fail)] [-holdoff] [-ack-retries n] [-ack-timeout microseconds] [-v] [-q]
DESCRIPTION
The solterm program allows a user to make a remote serial connection over IPMI. The requires that the remote system support IPMI 2.0
Serial Over LAN.
OPTIONS
<connection parms>
The parameters for the connection depend on the connection type. These are all described in openipmi_conparms (7)
-e escape_char
The character to use to escape, or exit, the program. Entering this character right after a newline is entered causes the program
to go into command mode. A single character after this performs a command. The default escape character is "~" as shown below.
Supported commands are:
~. Terminate the program
~B Send a serial BREAK over the connection
~F Flush all buffers
~R Assert the Ring Indicator (RI) line
~r Deassert the Ring Indicator (RI) line
~D Assert DCD and DSR lines
~d Deassert DCD and DSR lines
~C Pause the output using CTS
~c Put CTS under BMC control
~? Help on escape commands
~~ Enter the escape character twice to send it.
-notencrypted
Do not encrypt the SOL data going over the connection.
-notauthenticated
Do not do integrity checks on the SOL data going over the connection.
-bitrate
Set the bitrate to the given value. The default is whatever the BMC has set it to.
-alerts
This specifies what to do if a alert that requires a callout occurs on the line.
succeed
specifies that serial/modem alerts are to succeed while SoL is active.
deferred
specifies that serial/modem alerts are to be deferred for the duration of the SoL session.
fail specifies that serial/modem alerts automatically fail during the SoL session. This is the default.
-holdoff
Specifies that CTS, DTR, and DSR are to be deasserted at the start of the SoL session so that the configuration may be modified
before the handshake is released.
-v Be more verbose. Maybe specified multiple time for more output.
-q Be less verbose. Maybe specified multiple time for less output.
SEE ALSO openipmi_conparms(7)KNOWN PROBLEMS
None
AUTHOR
Darius Davis <dariusd@users.sourceforge.net>
OpenIPMI 05/13/03 solterm(1)