ILOM AND ALOM IP adresses

hi guys

How to know ILOM and ALOM ip address.

how to find the ilom alerts and alom alerts can one help out pls


thanks,
deepu.

---------- Post updated at 04:39 AM ---------- Previous update was at 04:38 AM ----------

Quote:
Originally Posted by pradeepaasuri
hi guys

How to know ILOM and ALOM ip address.

how to find the ilom alerts and alom alerts can one help out pls


thanks,
deepu.

Last edited by Scott; 04-28-2011 at 08:11 PM.. Reason: Moved to Solaris forum - please do not Hijack threads
 

10 More Discussions You Might Find Interesting

1. Solaris

Setting up static ip-adresses, Solaris 10

Hello, Iam having problems getting more then one ip to work here is my setup! Hostname: nexus NIC: e000g1 (example ips) My ips 80.80.80.15 to 80.80.80.20 Defaultrouter 80.80.80.1 nameservers 80.80.80.100 and 80.80.80.200 How would i do this? Any help would be mutch appriciated!... (7 Replies)
Discussion started by: empty
7 Replies

2. UNIX for Dummies Questions & Answers

multiple IP adresses on one machine

hello people i hope you can please help me. i have a server and several ip-addresses pointing to it. now i want a) that the server can be reached on all ip adresses from the internet b) that i can access the internet from the server and decide which IP-address is being used ( i can... (4 Replies)
Discussion started by: scarfake
4 Replies

3. Solaris

LOM ALOM ILOM ELOM RSC SP commands equivalent

Has anyone got an equivalent commands sheet for all Sun's serial or network management ports? (1 Reply)
Discussion started by: son_t
1 Replies

4. Shell Programming and Scripting

Uniq adresses with number of occurrence

Alo I have a file with a lot of addresses where I want to list unique addresses and the number of theirs occurrence. I have this input file: 0011bd09 ea 01 0b 04 ea 01 0b 38-bd 11 00 98 15 cb 01 00 .......8........ 0011bd09 ea 11 00 98 15 cb 01 00-00 00 00 d8 3d 8d 01 94 ... (5 Replies)
Discussion started by: chitech
5 Replies

5. UNIX for Advanced & Expert Users

ILOM Alert messages to Solaris OS - X4250 (Intel based NO ALOM)

Hi, I have a problem when running some tests. I unplug one power cable from the server. No message is sent to/var/adm/messages On the ILOM GUI, it shows power state deasserted. Anyone knows how to forward this message to the OS, perhaps using the alert management settings? IPMI,snmp?... (1 Reply)
Discussion started by: ulemsee
1 Replies

6. Solaris

Difference b/n ALOM and ALOM CMT

Hi Everyone. What is the differece b/n ALOM and ALOM CMT Service processor. I am trying reset ALOM login/passwd using scadm utility on T2000, while I am googling I came cross ALOM CMT doesnt support scadm utility, but ALOM supports. Not sure how different are these. Thanks, (0 Replies)
Discussion started by: bobby320
0 Replies

7. Solaris

Resetting ALOM

Hi gurus, I have a sun netra 240 server. I want to get to the ALOM but it always ask for login and password. Can anyone tell me how I can reset the ALOM it to default so I can be able to configure it? Thanks lots. (2 Replies)
Discussion started by: cjashu
2 Replies

8. Shell Programming and Scripting

Convertin IP adresses from a column to a raw + add a comma between addresses

Hi all, I have a list of IP addresses in a column in a text file name ipaddress.txt 192.168.0.1 192.168.0.2 192.168.0.5 192.168.0.4 192.168.0.5 I would like to convert ipaddress.txt to have the following thing : 192.168.0.1, 192.168.0.2, 192.168.0.3,192.168.0.4,192.168.0.5 I know... (4 Replies)
Discussion started by: oliv66
4 Replies

9. Solaris

Alom

Hi, How to set ip address on eth0 for access ssh from ALOM? Is it possible? Now i cannot access it because don't have VGA. I keep try to access using ssh. Please guide me. Thanks. (16 Replies)
Discussion started by: mzainal
16 Replies

10. Hardware

Alom ?

Hi all, I have some problems with the fan FT0.F0, which looks like has a problem with the PROM/ALOM ( I am nor sure who).....but, in fact, the fan is working properly even in other V440 Sparc Server. We checked HW comunication between Fan and the MotherBoard, and we think is a problem of... (8 Replies)
Discussion started by: proof_enrique
8 Replies
tsalarm(7D)							      Devices							       tsalarm(7D)

NAME
tsalarm - Alarm device driver SYNOPSIS
tsalarm@0:ctl DESCRIPTION
The tsalarm driver is a Multi-threaded, loadable non-STREAMS pseudo driver that manages ALOM alarms. The tsalarm driver provides an inter- face through which alarm relays can be controlled on SUNW,Netra-240 and SUNW,Netra-440 platforms. HARDWARE INTERFACE
The alarm hardware differs depending on platform. The Netra 240 and 440 platforms features four dry contact alarm relays which are controlled by ALOM. You can set each alarm to "on" or "off" by using ioctl interfaces provided from the host. The four alarms are labeled as "critical," "major," "minor," and "user." The user alarm is set by a user application depending on system condition. LED's in front of the box provide a visual indication of the four alarms. The number of alarms and their meanings/labels may vary across platforms. IOCTLS
The interface provided by the tsalarm driver comprises ioctls that enable applications to manipulate the alarm module. The alarm module is accessed via two device nodes: i) /dev/lom and /dev/tsalarm:ctl. The following ioctls are supported by the /dev/lom and /dev/tsalarm:ctl devices: TSIOCALCTL - Turn an alarm on or off. The argument is a pointer to the ts_aldata_t/lom_aldata_t structure. This structure is described below. alarm_no member is an integer which specifies the alarm to which the command is to be applied. The alarm_state/state structure member indicates the state to which the alarm should be set (where 0 == off). An error (EINVAL) is returned if either an invalid alarm_no or invalid alarm_state is pro- vided. TSIOCALSTATE - Get the state of the alarms. The argument is a pointer to the ts_aldata_t/lom_aldata_t structure. This structure is described below. alarm_no member is an integer which indicates the alarm to which the command will be applied. The alarm_state member holds the alarm's current state and is filled in by the driver. A zero indicates that the alarm is off. An error (EINVAL) is returned if an invalid alarm_no is provided. The struc- tures and definitions for the values are defined below. Alarm values: The following old style values are defined in <lom.io.h> #define ALARM_NUM_0 0 /* number of zero'th alarm */ #define ALARM_NUM_1 1 /* number of first alarm */ #define ALARM_NUM_2 2 /* number of second alarm */ #define ALARM_NUM_3 3 /* number of third alarm */ Alarm values defined in <lom.io.h> #define ALARM_OFF 0 /* Turn off alarm */ #define ALARM_ON 1 /* Turn on alarm */ Alarm Data Structure: This structure is defined in <lom.io.h> typedef struct { int alarm_no; /* alarm to apply command to */ int alarm_state; /* state of alarm (0 == off) */ } ts_aldata_t; Use the following LOM interfaces to get and set the alarms. These definitions are included in <lom_io.h> #define ALARM_CRITICAL 0 /* number of critical alarm */ #define ALARM_MAJOR 1 /* number of major alarm */ #define ALARM_MINOR 2 /* number of minor alarm */ #define ALARM_USER 3 /* number of user alarm */ The following alarm data structure is provided in <lom_io.h>: typedef struct { int alarm_no; int state; } lom_aldata_t; ERRORS
An open() will fail if: ENXIO The driver is not installed in the system. An ioctl() will fail if: EFAULT There was a hardware failure during the specified operation. EINVAL The alarm number specified is not valid or an invalid value was supplied. ENXIO The driver is not installed in the system or the monitor callback routine could not be scheduled. EXAMPLES
How to set an alarm: #include <sys/unistd.h> #include <fcntl.h> #include <stdio.h> #include <lom_io.h> #define LOM_DEVICE "/dev/lom" int main() { lom_aldata_t lld; int fd = open(LOM_DEVICE, O_RDWR); if (fd == -1) { printf("Error opening device: %s0, LOM_DEVICE); exit(1); } lld.alarm_no = ALARM_CRITICAL; /* Set the critical alarm */ lld.state = ALARM_ON; /* Set the alarm */ if (ioctl(fd, LOMIOCALCTL, (char *)&lld) != 0) printf("Setting alarm failed"); else printf("Alarm set successfully"); close(fd); } FILES
/dev/lom LOM device. /dev/tsalarm:ctl Alarm control device. /platform/platform/kernel/drv/sparcv9/tsalarm Device driver module. /platform/SUNW,Netra-240/kernel/drv/tsalarm.conf Driver configuration file. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcarx.u | +-----------------------------+-----------------------------+ |Architecture |SPARC | +-----------------------------+-----------------------------+ SEE ALSO
attributes(5) Writing Device Drivers SunOS 5.10 16 Mar 2004 tsalarm(7D)
All times are GMT -4. The time now is 03:14 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy