Sponsored Content
Operating Systems Solaris Solaris 10 Speed and Duplex Settings: bge Post 302349311 by brialt1 on Monday 31st of August 2009 03:55:18 PM
Old 08-31-2009
Here is the code located in the /platform/sun4u/kernel/drv/bge.conf


Code:
bge-rx-rings            = 1;
bge-tx-rings            = 1;
# interface bge0
name="bge" parent="/pci@0,600000/pci@0/pci@1/pci@0" unit-address="4" \
adv_autoneg_cap=0 adv_1000fdx_cap=1 adv_1000hdx_cap=0 \
adv_100fdx_cap=0 adv_100hdx_cap=0 adv_100T4_cap=0 adv_10fdx_cap=0 \
adv_10hdx_cap=0;

# interface bge1
name="bge" parent="/pci@0,600000/pci@0/pci@1/pci@0" unit-address="4,1" \
adv_autoneg_cap=0 adv_1000fdx_cap=0 adv_1000hdx_cap=0 \
adv_100fdx_cap=1 adv_100hdx_cap=0 adv_100T4_cap=0 adv_10fdx_cap=0 \
adv_10hdx_cap=0;

# interface bge2
name="bge" parent="/pci@0,600000/pci@0/pci@2/pci@0" unit-address="4" \
adv_autoneg_cap=0 adv_1000fdx_cap=1 adv_1000hdx_cap=0 \
adv_100fdx_cap=0 adv_100hdx_cap=0 adv_100T4_cap=0 adv_10fdx_cap=0 \
adv_10hdx_cap=0;

# interface bge3
name="bge" parent="/pci@0,600000/pci@0/pci@2/pci@0" unit-address="4,1" \
adv_autoneg_cap=0 adv_1000fdx_cap=1 adv_1000hdx_cap=0 \
adv_100fdx_cap=0 adv_100hdx_cap=0 adv_100T4_cap=0 adv_10fdx_cap=0 \
adv_10hdx_cap=0;

 

10 More Discussions You Might Find Interesting

1. Solaris

Duplex Settings

Hi All I've been having a lot of errors logged on the Cisco Catalyst (4000 series) which one of my Solaris servers is patched into. I have a feeling they are duplex related, but I'm a bit stuck as to how to confirm that. How do I: 1. Check the duplex settings on my eri0 card? 2. Set the... (3 Replies)
Discussion started by: saabir
3 Replies

2. IP Networking

NIC speed 100M/full duplex problem

I have a TOSHIBA AS7000 B150 Sun Box I wanted to run it with 100M/full duplex I had added this to the /etc/system file to make to setting permenant So it would be set correctly on reboot. set eri:eri_adv_100fdx_cap=1 set eri:eri_adv_100hdx_cap=0 set eri:eri_adv_autoneg_cap=0 But when I... (4 Replies)
Discussion started by: AirWalker83
4 Replies

3. HP-UX

command to change duplex settings..

Hi Folks, I want the command to change the duplex settings of a HP-UX server. Thanks in advance. Sagar. (2 Replies)
Discussion started by: sag71155
2 Replies

4. Solaris

gigabit - fix speed/duplex on the switch ? or autoneg ?

Hi there We have a bit of a debate going here over what the prefered method is for setting 1000/Full on e1000g or nge interfaces is. As you aware the Solaris configration files for nge and e1000g dont allow you to "fix" 1000/Full but instead allow you to set auto-negotiate to ON but only... (1 Reply)
Discussion started by: hcclnoodles
1 Replies

5. UNIX for Advanced & Expert Users

How to set full duplex for solaris 5.5

I would like to change half duplex to full duplex on solaris 5.5. I tried with below commands but they didnt work on solaris 5.5. #ndd -set /dev/le adv_100fdx_cap 1 (6 Replies)
Discussion started by: csreenivas
6 Replies

6. Infrastructure Monitoring

How to find the duplex speed on Windows

Hi, In UNIX, it's very easy to find the duplex speed. But in Windows, is there a easy way to find the duplex speed? I can't go to over 100 servers to find this out, I was wondering if I run one command to do this? Please advice. (2 Replies)
Discussion started by: samnyc
2 Replies

7. Solaris

How to find half duplex or full duplex

Hi, How to find whether the server is running with half duplex or full duplex. I tried with the following command ndd -get /dev/ but am not getting any output,. Is the command correct? Also let me know how to change from half to full duplex. (1 Reply)
Discussion started by: rogerben
1 Replies

8. AIX

How to change Speed Duplex

How to change Speed Duplex ! How to change Speed Duplex by command chdev -P -l ent1 -a media_speed=1000_Full_Duplex How to change Speed Duplex by Smitty . smitty chgenet -> select adapter -> change Media speed etc. -> set "Apply change to DATABASE only" to yes -> Enter -> ... (0 Replies)
Discussion started by: ITHelper
0 Replies

9. AIX

Connected and Running with half duplex speed

VIO Server connected to switch port and running with half duplex speed on one of the shared ethernet adapter. We have verified at switch end and everythings looks good. Other ethernet adapter in the VIO server are connected and running in Full duplex speed. Please help me find why this shared... (4 Replies)
Discussion started by: mugunthanvh
4 Replies

10. Shell Programming and Scripting

Need script help for monitoring duplex settings

So I have a server I am trying to set up a script to send a Wall message notifying of my eth0 nic being set to 100 half duplex instead of 100 full duplex. I know I am trying to read from /etc/sysconfig/network/ifcfg-eth0 to pull the parameters STARTMODE=onboot BOOTPROTO=static... (6 Replies)
Discussion started by: lutador72
6 Replies
igb(7D) 							      Devices								   igb(7D)

NAME
igb - Intel 82575 1Gb PCI Express NIC Driver SYNOPSIS
/dev/igb* DESCRIPTION
The igb Gigabit Ethernet driver is a multi-threaded, loadable, clonable, GLD-based STREAMS driver supporting the Data Link Provider Interface, dlpi(7P), on Intel 82575 Gigabit Ethernet controllers. The igb driver functions include controller initialization, frame transmit and receive, promiscuous and multicast support, and error recovery and reporting. The igb driver and hardware support auto-negotiation, a protocol specified by the 1000 Base-T standard. Auto-negotiation allows each device to advertise its capabilities and discover those of its peer (link partner). The highest common denominator supported by both link partners is automatically selected, yielding the greatest available throughput, while requiring no manual configuration. The igb driver also allows you to configure the advertised capabilities to less than the maximum (where the full speed of the interface is not required), or to force a specific mode of operation, irrespective of the link partner's advertised capabilities. APPLICATION PROGRAMMING INTERFACE
The cloning character-special device, /dev/igb, is used to access all Intel 82575 Gigabit devices installed within the system. The igb driver is managed by the dladm(1M) command line utility, which allows VLANs to be defined on top of igb instances and for igb instances to be aggregated. See dladm(1M) for more details. You must send an explicit DL_ATTACH_REQ message to associate the opened stream with a particular device (PPA). The PPA ID is interpreted as an unsigned integer data type and indicates the corresponding device instance (unit) number. The driver returns an error (DL_ERROR_ACK) if the PPA field value does not correspond to a valid device instance number for the system. The device is initialized on first attach and de- initialized (stopped) at last detach. The values returned by the driver in the DL_INFO_ACK primitive in response to your DL_INFO_REQ are: o Maximum SDU is 9000. o Minimum SDU is 0. o DLSAP address length is 8. o MAC type is DL_ETHER. o SAP (Service Access Point) length value is -2, meaning the physical address component is followed immediately by a 2-byte SAP component within the DLSAP address. o Broadcast address value is the Ethernet/IEEE broadcast address (FF:FF:FF:FF:FF:FF). Once in the DL_ATTACHED state, you must send a DL_BIND_REQ to associate a particular SAP with the stream. CONFIGURATION
By default, the igb driver performs auto-negotiation to select the link speed and mode. Link speed and mode can be any one of the follow- ing, (as described in the IEEE803.2 standard): 1000 Mbps, full-duplex. 100 Mbps, full-duplex. 100 Mbps, half-duplex. 10 Mbps, full-duplex. 10 Mbps, half-duplex. The auto-negotiation protocol automatically selects speed (1000 Mbps, 100 Mbps, or 10 Mbps) and operation mode (full-duplex or half-duplex) as the highest common denominator supported by both link partners. Alternatively, you can set the capabilities advertised by the igb device using ndd(1M). The driver supports a number of parameters whose names begin with adv_ (see below). Each of these parameters contains a boolean value that determines if the device advertises that mode of operation. For example, the adv_1000fdx_cap parameter indicates if 1000M full duplex is advertised to link partner. The adv_autoneg cap parameter controls whether auto-negotiation is performed. If adv_autoneg_cap is set to 0, the driver forces the mode of operation selected by the first non-zero parameter in priority order as shown below: (highest priority/greatest throughput) adv_1000fdx_cap 1000Mbps full duplex adv_100fdx_cap 100Mpbs full duplex adv_100hdx_cap 100Mbps half duplex adv_10fdx_cap 10Mpbs full duplex adv_10hdx_cap 10Mpbs half duplex (lowest priority/least throughput) All capabilities default to enabled. Note that changing any capability parameter causes the link to go down while the link partners renego- tiate the link speed/duplex using the newly changed capabilities. FILES
/dev/igb* Special character device. /kernel/drv/igb 32-bit device driver (x86). /kernel/drv/amd64/igb 64-bit device driver (x86). /kernel/drv/sparcv9/igb 64-bit device driver (SPARC). /kernel/drv/igb.conf Configuration file. SEE ALSO
dladm(1M), ndd(1M), netstat(1M), driver.conf(4), attributes(5), streamio(7I), dlpi(7P), Writing Device Drivers STREAMS Programming Guide Network Interfaces Programmer's Guide SunOS 5.11 20 Jul 2007 igb(7D)
All times are GMT -4. The time now is 04:49 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.