Sponsored Content
Full Discussion: POWER6 VIO Failover
Operating Systems AIX POWER6 VIO Failover Post 302315286 by filosophizer on Tuesday 12th of May 2009 03:57:57 AM
Old 05-12-2009
thanks for your quick answer.

Okay, that would help me have the LPAR alive.. thru the AIX O/S

how about the SAN disks ?

From my DS8000 i have created logical disks and assigned to VIO_SERVER_1
Create Virtual SCSI Adapter on VIO_SERVER_1 and LPAR_1 + LPAR_2 + LPAR_3 + LPAR_4

Allocation
VIO_SERVER_1 disk10 (From SAN) given to LPAR_1
VIO_SERVER_1 disk11 (From SAN) given to LPAR_2
VIO_SERVER_1 disk12 (From SAN) given to LPAR_3
VIO_SERVER_1 disk13 (From SAN) given to LPAR_4

Now if the Vio_server_1 goes down all those disks will disappear from LPAR_1 + LPAR_2 + LPAR_3 + LPAR_4

1) How can I make failover or redundancy for it with VIO_Server_2 (other than Mirroring)

2) Can I use Mobility under HMC to move the LPAR Partition under the same Managed system to another VIO Server (in my case VIO_SERVER_2 ? )

thanks
 

9 More Discussions You Might Find Interesting

1. AIX

Oracle 10G best practices on Power6 AIX5.3

Can anyone point me to any best practices for partitioning, resource prerequisites, and implementation of Oracle 10G release 2 with RAC on 2 power6 550's running AIX5.3 as a cluster? (1 Reply)
Discussion started by: JodyTek
1 Replies

2. AIX

Power6 Virtual Fibre Channel Adapter

Hello, Searched in all IBM Redbooks and on the internet and couldn't find anything about the new feature of POWER 6 which Virtual Fibre ( Fiber ) channel adapter. It is similar to virtual scsi adapter. In my client partition I created the virtual Fibre Adapter mapped it with the VIO... (1 Reply)
Discussion started by: filosophizer
1 Replies

3. AIX

vio server and vio client

Hi, I want to know wheather partition size for installation of vio client can be specified on vio server example If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies

4. AIX

AIX 6.1 Power6 - Sys CPU utilization twice that of User

Hello, We just purchased two new 4-way (one active one failover) 5Ghz Power6 Servers (failover) with 64GB RAM (32GB per node) runing AIX 6.1 with two LPARs per node connected to our SAN with two 4GB HBAs. The PROD LPAR has 2 dedicated CPUs (4 virtual) and the TEST LPAR has 2 dedicated CPUs. ... (3 Replies)
Discussion started by: troym72
3 Replies

5. AIX

HACMP with VIO, service IP failover

Would anyone please kindly help to solve this problem... An LPAR with the below network configuration. ent0 and ent1 are logical lan (virtual ethernet) from VIO SEA. en0 1.2.3.4 <- boot ip 192.168.1.1 <- persistent ip 192.168.1.10 <- service ip en1 11.22.33.44 <- boot ip When I... (6 Replies)
Discussion started by: skeyeung
6 Replies

6. AIX

vio server ethernet to vio client ethernet(concepts confusing)

Hi In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID. Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies

7. AIX

Power6 vs. Power7 hardware performance

I know I will get blasted for posting here, not know where to post this, however, I have performance question between the 2 platforms. Not knowing the exact processors in each box, but the Power6 Platform clock speed is 4400 (?? at least what was told to me), and the Power7 clock speed is 3500.... (5 Replies)
Discussion started by: mrmurdock
5 Replies

8. AIX

How to get power6 power FRU?

how to get power6 power FRU? the power5 can get by this command: lscfg -vp | grep -p 'AC PS' | grep FRU however, the power6 machine cannot get any info for that command. thanks (1 Reply)
Discussion started by: rainbow_bean
1 Replies

9. AIX

Hard drive compatibility for POWER6 p520

Hi, I have recently inherited an old p520 from work running AIX 6.1, based on the POWER6 CPU. I'm planning to play around with it and use it to learn the system, so this is a purely personal project. The machine is not under a support contract any more. I am looking to replace one of the disks... (11 Replies)
Discussion started by: topcat
11 Replies
fp(7d)                                                                Devices                                                               fp(7d)

NAME
fp - Sun Fibre Channel port driver DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter port management and other capabilities through well-defined fibre channel adapter driver interfaces. The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri- vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in LIRP and LILP stages of loop initialization. CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties: mpxio-disable Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no" activates I/O multipathing, while mpxio-disable="yes" disables the feature. Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4: name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0 mpxio-disable="yes"; manual_configuration_only Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con- figuration of devices. FILES
/kernel/drv/fp 32-bit ELF kernel driver (x86) /kernel/drv/amd64/fp 64-bit ELF kernel driver (x86) /kernel/drv/sparcv9/fp 64-bit ELF kernel driver (SPARC) /kernel/drv/fp.conf fp driver configuration file. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |mpxio-disable |Unstable | +-----------------------------+-----------------------------+ |manual_configuration_only |Obsolete | +-----------------------------+-----------------------------+ |Availability |SUNWfctl | +-----------------------------+-----------------------------+ SEE ALSO
cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D) Writing Device Drivers Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994 Fibre Channel Generic Services (FC-GS-2) Project 1134-D Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996 Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996 SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996 SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996 SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998 Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998 SunOS 5.10 2 Dec 2004 fp(7d)
All times are GMT -4. The time now is 07:50 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy