LFTP Mirroring


 
Thread Tools Search this Thread
Top Forums UNIX for Advanced & Expert Users LFTP Mirroring
# 1  
Old 07-21-2008
LFTP Mirroring

LFTP Mirroring
We are planning to use lftp to mirror some of the files and
directories on to the remote server.

What we exactly want to do is mirror some of the directories and
exclude some of the the directories from "/" i.e. main root. . What
lftp is doing is mirroring all the directories. It seems the include
and exclude doesnt work properly.

The script that we are trying to run is as below:

HomeBackUpDir=/
RemotePath=/data/
lftp -u $RemoteUser,$RemotePass -e "mirror --dry-run --reverse
--delete -I '/home/*/web/' -I '/home/*/data/' -i
'/home/cla_backup/scripts/' -i '/etc/apache2' -X
'/home/*/data/lucene_data/' -X '*data/temp/*' -X '*backup/*' -X
'*templater_cache/*' --only-newer --ignore-time --verbose=4
$HomeBackUpDir $RemotePath" $RemoteHost

What we intend to do is to mirror
/etc/apache2/
in the home/ directory wherever there is a web/ directory mirror that
in the home/ directory wherever there is a data/ directory mirror that
/home/cla_backup/scripts

Exclude:
in the home/ directory wherever there is a data/lucene_data/
/data/temp/
backup/
templater_cache/


The above script tries to mirror even directories like /dev, /proc and
all other directories that are present in "/".
Login or Register to Ask a Question

Previous Thread | Next Thread

9 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

Error with LFTP

I use below ftp command to push the file from UNIX server to Mainframe system. (lftp -d -e "set ftp:passive-mode false; put -a ${SPOOLFILE} -o ${FNAME}; exit" -u ${id},${paswd} ${host} ) >> $ftplog To ftp the file successfully i need to get the out put for FNAME as "'filename'" (double... (5 Replies)
Discussion started by: zooby
5 Replies

2. Shell Programming and Scripting

Lftp command

Hello, I am trying to write a script that will lftp a file. The parameters are being passed in to the script from ETL tool. The put command is not working. put $file_name $tgt_file_name in the function ftpfile(). When I hardcode the file name with path its working. can some one help me... (5 Replies)
Discussion started by: skatpally
5 Replies

3. Shell Programming and Scripting

lftp is not working.how to replace lftp with expect utility using same .cfg file.

We have lftp command inside shell file. which is intern calling .cfg file for transferring the file from one server to other. Below command to not working. lftp -e "set net:max-retries 1; set net:reconnect-interval-base 1; put -E -O /destinationdir/inbox/ /sourcedir/test.txt; bye" -u... (4 Replies)
Discussion started by: johnsnow
4 Replies

4. UNIX for Dummies Questions & Answers

Lftp operation

dear all, I need to get files from ftp when only files consist of words 'EUROPE' ftp sources in folder /ftp1/ftp2/ftp3/201409 files inside /ftp1/ftp2/ftp3/201409is as below 201409_EUROPE_citizen.txt 201409_EUROPE_natality.txt 201409_EUROPE_occupancy.txt 201409_ASIA_citizen.txt... (1 Reply)
Discussion started by: radius
1 Replies

5. Red Hat

Lftp issue

I installed KVM and configured two virtual machines in it server1.example.com(192.168.100.193) and tester1.example.com(192.168.100.230).I want to access server1.example.com from tester1.example.com over lftp.As far as networking is concerned between both I do have some doubts. I tried ping and... (5 Replies)
Discussion started by: shazgaurav
5 Replies

6. Shell Programming and Scripting

Lftp with dialog

Hi all. I want to know, if there is any chance to pass lftp listing to CLI dialog. I want to make an interactive CLI ftp manager, based on lftp. Version of dialog I use: root@dlink:~# dialog -v cdialog (ComeOn Dialog!) version 1.1-20100428 (0 Replies)
Discussion started by: n158
0 Replies

7. UNIX for Advanced & Expert Users

lftp connection issues

Hi guys, We are receiving fatal error while trying to use lftp client to connect to an external server using ftps protocol. It seems to connect but when I issue 'ls' command, it fails with below error: $ lftp -u user,pwd ftps://<URL>:990/Submit lftp user@URL:~> ls ls: Fatal error:... (0 Replies)
Discussion started by: nice_chapp
0 Replies

8. UNIX for Advanced & Expert Users

lftp: Option to lftp a file, wait and download a file as soon as its created

Please let me know what is lftp options combination to wait and download a file from target as soon as its gets created. I tried with different options but not able to get it working as I need any help would be appreciated (4 Replies)
Discussion started by: bmkux
4 Replies

9. Shell Programming and Scripting

lftp, get file list

hello I need script which give me file list from server (4 Replies)
Discussion started by: stahoo23
4 Replies
Login or Register to Ask a Question
CCD(4)							   BSD Kernel Interfaces Manual 						    CCD(4)

NAME
ccd -- Concatenated Disk driver SYNOPSIS
device ccd DESCRIPTION
The ccd driver provides the capability of combining one or more disks/partitions into one virtual disk. This document assumes that you are familiar with how to generate kernels, how to properly configure disks and devices in a kernel configura- tion file, and how to partition disks. In order to compile in support for the ccd, you must add a line similar to the following to your kernel configuration file: device ccd # concatenated disk devices As of the FreeBSD 3.0 release, you do not need to configure your kernel with ccd but may instead use it as a kernel loadable module. Simply running ccdconfig(8) will load the module into the kernel. A ccd may be either serially concatenated or interleaved. To serially concatenate the partitions, specify the interleave factor of 0. Note that mirroring may not be used with an interleave factor of 0. There is a run-time utility that is used for configuring ccds. See ccdconfig(8) for more information. The Interleave Factor If a ccd is interleaved correctly, a ``striping'' effect is achieved, which can increase sequential read/write performance. The interleave factor is expressed in units of DEV_BSIZE (usually 512 bytes). For large writes, the optimum interleave factor is typically the size of a track, while for large reads, it is about a quarter of a track. (Note that this changes greatly depending on the number and speed of disks.) For instance, with eight 7,200 RPM drives on two Fast-Wide SCSI buses, this translates to about 128 for writes and 32 for reads. A larger interleave tends to work better when the disk is taking a multitasking load by localizing the file I/O from any given process onto a single disk. You lose sequential performance when you do this, but sequential performance is not usually an issue with a multitasking load. An interleave factor must be specified when using a mirroring configuration, even when you have only two disks (i.e., the layout winds up being the same no matter what the interleave factor). The interleave factor will determine how I/O is broken up, however, and a value 128 or greater is recommended. ccd has an option for a parity disk, but does not currently implement it. The best performance is achieved if all component disks have the same geometry and size. Optimum striping cannot occur with different disk types. For random-access oriented workloads, such as news servers, a larger interleave factor (e.g., 65,536) is more desirable. Note that there is not much ccd can do to speed up applications that are seek-time limited. Larger interleave factors will at least reduce the chance of having to seek two disk-heads to read one directory or a file. Disk Mirroring You can configure the ccd to ``mirror'' any even number of disks. See ccdconfig(8) for how to specify the necessary flags. For example, if you have a ccd configuration specifying four disks, the first two disks will be mirrored with the second two disks. A write will be run to both sides of the mirror. A read will be run to either side of the mirror depending on what the driver believes to be most optimal. If the read fails, the driver will automatically attempt to read the same sector from the other side of the mirror. Currently ccd uses a dual seek zone model to optimize reads for a multi-tasking load rather than a sequential load. In an event of a disk failure, you can use dd(1) to recover the failed disk. Note that a one-disk ccd is not the same as the original partition. In particular, this means if you have a file system on a two-disk mir- rored ccd and one of the disks fail, you cannot mount and use the remaining partition as itself; you have to configure it as a one-disk ccd. You cannot replace a disk in a mirrored ccd partition without first backing up the partition, then replacing the disk, then restoring the partition. Linux Compatibility The Linux compatibility mode does not try to read the label that Linux' md(4) driver leaves on the raw devices. You will have to give the order of devices and the interleave factor on your own. When in Linux compatibility mode, ccd will convert the interleave factor from Linux terminology. That means you give the same interleave factor that you gave as chunk size in Linux. If you have a Linux md(4) device in ``legacy'' mode, do not use the CCDF_LINUX flag in ccdconfig(8). Use the CCDF_NO_OFFSET flag instead. In that case you have to convert the interleave factor on your own, usually it is Linux' chunk size multiplied by two. Using a Linux RAID this way is potentially dangerous and can destroy the data in there. Since FreeBSD does not read the label used by Linux, changes in Linux might invalidate the compatibility layer. However, using this is reasonably safe if you test the compatibility before mounting a RAID read-write for the first time. Just using ccdconfig(8) without mounting does not write anything to the Linux RAID. Then you do a fsck.ext2fs (ports/sysutils/e2fsprogs) on the ccd device using the -n flag. You can mount the file system read-only to check files in there. If all this works, it is unlikely that there is a problem with ccd. Keep in mind that even when the Linux compatibility mode in ccd is working correctly, bugs in FreeBSD's ex2fs implemen- tation would still destroy your data. WARNINGS
If just one (or more) of the disks in a ccd fails, the entire file system will be lost unless you are mirroring the disks. If one of the disks in a mirror is lost, you should still be able to back up your data. If a write error occurs, however, data read from that sector may be non-deterministic. It may return the data prior to the write or it may return the data that was written. When a write error occurs, you should recover and regenerate the data as soon as possible. Changing the interleave or other parameters for a ccd disk usually destroys whatever data previously existed on that disk. FILES
/dev/ccd* ccd device special files SEE ALSO
dd(1), ccdconfig(8), config(8), disklabel(8), fsck(8), mount(8), newfs(8), vinum(8) HISTORY
The concatenated disk driver was originally written at the University of Utah. BSD
August 9, 1995 BSD