Hi,
I connect the server to new SAN with FC (fiber channel). I run the scan but there is no multipath is installed on the server, how can I see which /dev/dm- is the right one so I can create pv (pvcreate)?
# cat /etc/SuSE-release
SUSE LINUX Enterprise Server 9 (x86_64)
VERSION = 9
PATCHLEVEL = 3
#
hi! i got a rhel 6.3 host that already have an xfs filesystem mounted from a SAN (let's call it SAN-1) whose size is 9TB.
i will be receiving another SAN (let's call it SAN-2) storage of 15TB size. this new addition is physically on another SAN storage. SAN-1 is on a Pillar storage while the new... (6 Replies)
Has anyone tried SAN to SAN mirroring on IBM DS SAN Storage.
DS5020 mentions Enhanced Remote Mirror to multi-LUN applications
I wonder if Oracle High availibility can be setup using Remote Mirror option of SAN ? (1 Reply)
Hi everyone,
I wonder if I can canvas any opinions or thoughts (good or bad) on SAN attaching a SUN V880/490 to an EMC Clarion SAN?
At the moment the 880 is using 12 internal FC-AL disks as a db server and seems to be doing a pretty good job. It is not I/O, CPU or Memory constrained and the... (2 Replies)
fp(7d) Devices fp(7d)NAME
fp - Sun Fibre Channel port driver
DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter
port management and other capabilities through well-defined fibre channel adapter driver interfaces.
The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri-
vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in
LIRP and LILP stages of loop initialization.
CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties:
mpxio-disable
Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no"
activates I/O multipathing, while mpxio-disable="yes" disables the feature.
Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified
ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4:
name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0
mpxio-disable="yes";
manual_configuration_only
Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be
enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default
behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con-
figuration of devices.
FILES
/kernel/drv/fp
32-bit ELF kernel driver (x86)
/kernel/drv/amd64/fp
64-bit ELF kernel driver (x86)
/kernel/drv/sparcv9/fp
64-bit ELF kernel driver (SPARC)
/kernel/drv/fp.conf
fp driver configuration file.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|mpxio-disable |Unstable |
+-----------------------------+-----------------------------+
|manual_configuration_only |Obsolete |
+-----------------------------+-----------------------------+
|Availability |SUNWfctl |
+-----------------------------+-----------------------------+
SEE ALSO cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D)
Writing Device Drivers
Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994
Fibre Channel Generic Services (FC-GS-2) Project 1134-D
Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996
Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996
SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998
Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998
SunOS 5.10 2 Dec 2004 fp(7d)