Sun SPARC Enterprise M-Series Servers Configuration Concepts
This Sun BluePrints article covers basic and advanced configuration concepts and goes through several sample configurations for Sun SPARC Enterprise M4000, M5000, M8000, and M9000 servers.
Good Day,
We have bought Sun Sparc Enterprise T5120 with pre-installed Solaris 10 Sparc
But i need on this server Solaris 9. I have inserted in to DVD-rom (USB DVD-rom) with Solaris 9 for Sparc.
Then log into shell and type: reboot -- cdrom.
System rebooted and i have this message:
... (3 Replies)
Hello,
Wondering if anyone can help me with mounting a file share from my Sun T2000 server running Solaris 10 to my connected 2530 disk array?
I believe I've connected the disk array correctly and I have created a volume on the array using the filesystem (Sun_SAM-FS, RAID-5).
The T2000... (15 Replies)
Hi,
I have Sun SPARC Enterprise T5140 and I can't access it via serial port using preconfigured administrator account, as described in Sun Integrated Lights Out Manager 2.0 User's Guide: I'm always receive "Login incorrect" message. I'm really confused! Does anyone experience such circumstances?... (12 Replies)
cvcd(1M) System Administration Commands cvcd(1M)NAME
cvcd - virtual console daemon
SYNOPSIS
/platform/platform_name/cvcd
DESCRIPTION
The virtual console daemon, cvcd, is a server process that supports the network console provided on some platforms. The cvcd daemon accepts
network console connections from a remote host (only one host at any given time). Console input is read from this connection and forwarded
to cvc(7D) by way of cvcredir(7D).
Similarly, console output is read from cvcredir(7D) and forwarded across the network console connection. If cvcd dies, console traffic is
automatically rerouted through an internal hardware interface.
The cvcd daemon normally starts at system boot time. Each domain supports only one cvcd process at a time.
Caution: On Sun Enterprise 10000 domains, cvcd uses a configuration file (/etc/ssphostname) to determine the name of the host from
which network console connections are allowed. If the remote console host is renamed, you must edit the configuration file
to reflect that change.
OPERANDS
The following operands are supported:
platform_name The official Sun platform name used in packaging and code. For example, for Sun Fire 15K servers, the platform_name
would be SUNW,Sun-Fire-15000.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Architecture |Sun Enterprise 10000 |
| |servers, Sun Fire High-End |
| |Systems |
+-----------------------------+-----------------------------+
|Availability |SUNWcvc.u |
+-----------------------------+-----------------------------+
SEE ALSO svcs(1), svcadm(1M), services(4), attributes(5), smf(5), cvc(7D), cvcredir(7D)
Sun Enterprise 10000 SSP Reference Manual
System Management Services (SMS) Reference Manual
NOTES
The cvcd service is managed by the service management facility, smf(5), under the service identifier:
svc:/system/cvc
Administrative actions on this service, such as enabling, disabling, or requesting restart, can be performed using svcadm(1M). The ser-
vice's status can be queried using the svcs(1) command.
SunOS 5.10 11 Aug 2004 cvcd(1M)