Today (Saturday) We will make some minor tuning adjustments to MySQL.

You may experience 2 up to 10 seconds "glitch time" when we restart MySQL. We expect to make these adjustments around 1AM Eastern Daylight Saving Time (EDT) US.


Install RHEL 7 on unsupported HP Smart Array (P400)

Login or Register to Reply

 
Thread Tools Search this Thread
# 1  
Install RHEL 7 on unsupported HP Smart Array (P400)

Hello community, after hours (days) spent to understand what's the problem reported also in the following thread: Can't boot RHEL7.2 due to "Start Job is Running"
I realize that the problem is the server itself. I opened a new thread since the issue in not related to the previous at all.

As per the following release note:
Chapter 25. Kernel - Red Hat Customer Portal

Smart Array P400 (the one mounted on my DL385G2 server) is not longer supported. So I tried to install RHEL 7.2 Enterprise Server directly on my Server, and the result is that it can't recognize the disks at all because the hpsa driver doesn't support it...

Anyone know if there is a workaround for that? I have only this sever, and I absolutely need to install RHEL7 due to software compatibility (I have to install a custom software).

Thank you
Lucas
# 2  
I think your only option is to try the hpsa driver's backward compatibility option:

Google Translate

If that doesn't work, I don't know what will.
# 3  
Thank you for response, but I already tried this solution without success... Well, after 2 days of headaches Smilie I finally solved the issue. I report the solution there in case someone need it.

First download the following ISO:
http://elrepo.org/people/akemi/testi...el7_x86_64.iso
It contains the kmod-cciss (modified kernel with old cciss driver). Then, this is the procedure:

- Write the ISO with kmod to a USB Key (with linux using dd or in Windows using utilities like USBIMG)
- Burn RHEL7.x ISO and boot from there
-At the very first screen, the one with the options to Install, Check disk and Troubleshoot etc.. hit ESC
-insert the USB memory stick in a USB port;
-you will get a prompt; type here "linux dd" without the quotes, hit enter and wait a while;
-select your USB drive, which probably will be "sdb"
-next select the driver by pressing "1";
-press "c (continue)" and now it will tell you that it is loading the driver;
-you will get back to to the drive list just press "c" one more time;
-the installer will start, and you will get your disks on RHEL installer

After installation we are able to start RHEL7 without issue on old Smart Array. The credit goes to a guy from centos forum, but I loose the page :/
Login or Register to Reply

|
Thread Tools Search this Thread
Search this Thread:
Advanced Search

More UNIX and Linux Forum Topics You Might Find Helpful
Is it possible to install RHEL 7 on top of RHEL 6?
magnus29
Hi We have RHEL 6.7 on an HP physical server and want to install RHEL 7 (not upgrade) on top of it by means of virtualization. Is it possible to install/configure RHEV/KVM virtualization on base RHEL 6.7 OS instance and then install RHEL 7 as a VM guest on it? If yes, could you please guide me...... Red Hat
1
Red Hat
Explain the difference between the commands cd ~smart and cd ~/smart
phunkypants
Is it possible for both commands to work?... UNIX for Dummies Questions & Answers
1
UNIX for Dummies Questions & Answers
Create RAID - Smart Array Tool - ML370
Zio Bill
Hi guys, i must install an old old old ml370 server... I must create a RAID 5 with my 4 SCSI disk. I need a SmartStart disk for create it or a Floppy Disk called "Array configuration Tool". I don't find it on the hp website...:mad::mad::mad: Anyone have it?? Thanks in advance. Zio... UNIX for Advanced & Expert Users
0
UNIX for Advanced & Expert Users
Smart Array on a RP4440
marvin51796
I have a new Rp4440 that has hp-ux 11.11 on it with a smart array 30 attached to it, HP says they are compatiable and i should be able to use it. I am looking for any help in setting up the array i have it all connected but dont know how to setup the array so the OS see's hard drives. I got no...... UNIX for Advanced & Expert Users
1
UNIX for Advanced & Expert Users
compaq smart array 532
farmacy
Trying to install Sco openserver on HP Proliant with this scsi controller but no scsi devices detected. Boot controller is set as the smart array 532 but SCSI diags do not detect any SCSI boot devices during boot sequence Any help appreciated... SCO
2
SCO

Featured Tech Videos