VERSYS Legacy System


 
Thread Tools Search this Thread
Top Forums Programming VERSYS Legacy System
# 1  
Old 04-28-2010
VERSYS Legacy System

I need help locating the tables that hold the demograhic data in this system on an AIX box. Does anyone know the path?
Login or Register to Ask a Question

Previous Thread | Next Thread

6 More Discussions You Might Find Interesting

1. Solaris

Determine if you are in a Legacy Zone?

Hi Folks, Just a quick question here, about Legacy Zones. Well more about how to determine if you are actually in one, on logging into a legacy zone - is there a quick way of checking that? Regards Gull04 (7 Replies)
Discussion started by: gull04
7 Replies

2. SCO

Need Help Installing Legacy System on Newer Hardware

We have a legacy software application that runs on SCO OpenServer 5.0.6, and the current server (built around 2003-04) is still running. I have been attempting to upgrade the hardware, to hopefully increase the time that we will have access to the data in this system, but am running into an... (13 Replies)
Discussion started by: spock9458
13 Replies

3. Solaris

NFS server on Legacy Container?

Hi All, I have a problem as follows. Historically, there was an Ultra10 workstation running Solaris 8 using automount to access NFS volumes on a Solaris 8 server. The Ultra 10 was retired and the Solaris 8 server has been migrated to a Legacy Container (Solaris 8 Branded, whole root,... (9 Replies)
Discussion started by: hicksd8
9 Replies

4. What is on Your Mind?

Tron Legacy

Watched it. Major disappointment. (10 Replies)
Discussion started by: ni2
10 Replies

5. Solaris

How to set up legacy services right on Solaris 10

I want to add auto startup and shutdown script to Solaris 10's legacy services as they run in Solaris 9 or in Linux. To make this work, I created the crontrol script in /etc/init.d and then link it to /etc/rc0.d and /etc/rc2.d directories. rc0.d is for shutdown and rc2.d is for srat. After I... (15 Replies)
Discussion started by: duke0001
15 Replies

6. Programming

CMI Legacy

Is there anyone who still uses CMI to connect to the legacy system , my c applications do uses the binaries and libraries for using the CMI functionality but i do not have access to the original source code , and since this is a very old stuff , i just could not get any source to get to knwo the... (0 Replies)
Discussion started by: dino_leix
0 Replies
Login or Register to Ask a Question
ifc_disable_mgmt_lun(5) 					File Formats Manual					   ifc_disable_mgmt_lun(5)

NAME
ifc_disable_mgmt_lun - select whether or not management luns are discovered in the legacy representation of mass storage devices VALUES
Failsafe Default Allowed values Enable discovery of management luns for array devices. Disable discovery of management luns for array devices. Recommended values DESCRIPTION
Management luns provide the means to access the control ports of Fibre Channel disk arrays. They are represented in both the legacy and the agile view of storage devices. The legacy representation of a management lun is typically created under a separate virtual extension bus node. The entry for a legacy management lun looks like this: On a system with a large number of storage devices connected, creation of management luns can result in an insufficient number of virtual extension buses for the legacy representation of data luns. Since the number of extension buses on a system is limited to 256, luns requiring virtual extension buses above 256 will be unusable through legacy device special files. Disabling the discovery and creation of management luns will free up virtual extension buses for use by data luns. Who Is Expected to Change This Tunable? System administrators who expect to use a large number of storage devices requiring more than 256 extension buses through legacy device special files. Restrictions on Changing Changes to this tunable take effect immediately. However, existing management luns will not be removed. When Should the Tunable Be Turned On? This tunable should be turned on when the system runs out of extension buses for configuring the legacy representation of data luns. What Are the Side Effects of Turning the Tunable Off? None. When Should the Tunable Be Turned Off? When the functionality provided by the management luns is desired. What Are the Side Effects of Turning the Tunable On? Existing management luns in the legacy representation will show up in the state. What Other Tunables Should Be Changed at the Same Time? None. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by HP. SEE ALSO
ioinit(1M), ioscan(1M), kctune(1M). Tunable Kernel Parameters ifc_disable_mgmt_lun(5)