Query: oneac
OS: opensolaris
Section: 8
Format: Original Unix Latex Style Formatted with HTML and a Horizontal Scroll Bar
ONEAC(8) NUT Manual ONEAC(8)NAMEoneac - Driver for Oneac UPS equipmentNOTEThis man page only documents the hardware-specific features of the oneac driver. For information about the core driver, see nutupsdrv(8).SUPPORTED HARDWAREThis driver supports various Oneac UPS families: o EG (late 80s, early 90s, plug-in serial interface card) o ON (early and mid-90s, plug-in serial interface card) o OZ (mid-90s on, DB-25 std., interface slot) o OB (early 2000's on, big cabinet, DB-25 std., interface slot) If your UPS is equipped with the Basic Interface card, use the genericups(8) driver.EXTRA ARGUMENTSThis driver supports the following optional settings in the ups.conf(5) file: testtime=num Change battery test time from the 2 minute default. offdelay=num Change shutdown delay time from 0 second default.INSTANT COMMANDSThis driver supports the following Instant Commands. (See upscmd(8)) All UPS units shutdown.return Turn off the load possibly after a delay and return when power is back. shutdown.stop Stop a shutdown in progress. shutdown.reboot Shut down the load briefly while rebooting the UPS. test.failure.start Starts a 15 second long simulation of an input power failure. test.battery.start.quick Start a "quick" battery test. The default time is 2 minutes. This time can be set in the ups.conf file. See testime above. test.battery.stop Stops a battery test that is in progress. All ON UPS units reset.input.minmax Reset the minimum and maximum input line voltage values seen since the last reset or power on. Newer ON UPS units test.panel.start Start testing the UPS panel. test.battery.start.deep Start a "deep" battery test. This test runs the UPS until the low battery point and then returns to the AC line. reset.input.minmax Reset the minimum and maximum input line voltage values seen since the last reset or power on. beeper.enable Enable UPS beeper/buzzer. beeper.disable Disable UPS beeper/buzzer. beeper.mute Mutes the UPS beeper/buzzer for the current alarm condition(s).WRITABLE VARIABLESSee upsrw(8) to see what variables are writable for the UPS. Note If your UPS supports writing battery.runtime.low, the new set value is to be entered in minutes (up to 99) but the reported value is reported in seconds (set value * 60). Note If your UPS supports input.transfer.low and input.transfer.high, those values are used to create an allowable output range. The UPS will do what it can to keep the output voltage value within the defined range (for example: tap change or switch to inverter).AUTHORBill Elliot <bill@wreassoc.com>, Eric Lawson <elawson@inficad.com>SEE ALSOThe core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 ONEAC(8)
Related Man Pages |
---|
safenet(8) - debian |
oneac(8) - freebsd |
oneac(8) - opensolaris |
oneac(8) - v7 |
oneac(8) - posix |
Similar Topics in the Unix Linux Community |
---|
need help in implementing simple interactive shell in C |
[spam] For Sale:Apple IPhone 3GS 32GB:$500usd,Apple Iphone 3GS 16Gb:$350usd |
Infraction for p002: Spammed Advertisements |