hpux man page for fcd_disable_mgmt_lun

Query: fcd_disable_mgmt_lun

OS: hpux

Section: 5

Format: Original Unix Latex Style Formatted with HTML and a Horizontal Scroll Bar

fcd_disable_mgmt_lun(5) 					File Formats Manual					   fcd_disable_mgmt_lun(5)

NAME
fcd_disable_mgmt_lun - select whether or not management luns are discovered in the legacy representation of mass storage devices
VALUES
Failsafe Default Allowed values Enable discovery of management luns for array devices. Disable discovery of management luns for array devices. Recommended values
DESCRIPTION
Management luns provide the means to access the control ports of Fibre Channel disk arrays. They are represented in both the legacy and the agile view of storage devices. The legacy representation of a management lun is typically created under a separate virtual extension bus node. The entry for a legacy management lun looks like this: On a system with a large number of storage devices connected, creation of management luns can result in an insufficient number of virtual extension buses for the legacy representation of data luns. Since the number of extension buses on a system is limited to 256, luns requiring virtual extension buses above 256 will be unusable through legacy device special files. Disabling the discovery and creation of management luns will free up virtual extension buses for use by data luns. The default value for this tunable is Who Is Expected to Change This Tunable? System administrators who expect to use a large number of storage devices requiring more than 256 extension buses through legacy device special files. Restrictions on Changing Changes to this tunable take effect immediately. However, existing management luns will not be removed. When Should the Tunable Be Turned On? This tunable should be turned on when the system runs out of extension buses for configuring the legacy representation of data luns. What Are the Side Effects of Turning the Tunable Off? None. When Should the Tunable Be Turned Off? When the functionality provided by the management lun is desired. What Are the Side Effects of Turning the Tunable On? Existing management luns in the legacy representation will show up in the state. What Other Tunables Should Be Changed at the Same Time? None.
WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at
AUTHOR
was developed by Hewlett-Packard Company.
SEE ALSO
ioinit(1M), ioscan(1M), kctune(1M). Tunable Kernel Parameters fcd_disable_mgmt_lun(5)
Related Man Pages
nstrpush(5) - hpux
enable_idds(5) - hpux
fcd_disable_mgmt_lun(5) - hpux
pci_eh_enable(5) - hpux
st_san_safe(5) - hpux
Similar Topics in the Unix Linux Community
mpxio in Solaris10 with NetApp FAS3140 problem
File and Data Validation.
Mpathadm showing no paths to 1 lun, others luns are fine
Restore of Netapp FC lun targets used as the disks for a zpool with exported zfs file systems
Incorporating the Moderator's Dashboard Into the Badging System or Killing It