Linux and UNIX Man Pages

Linux & Unix Commands - Search Man Pages

untimeout(9) [v7 man page]

TIMEOUT(9)						   BSD Kernel Developer's Manual						TIMEOUT(9)

NAME
timeout, untimeout, callout_handle_init, callout_init, callout_init_mtx, callout_init_rw, callout_stop, callout_drain, callout_reset, callout_schedule, callout_pending, callout_active, callout_deactivate -- execute a function after a specified length of time SYNOPSIS
#include <sys/types.h> #include <sys/systm.h> typedef void timeout_t (void *); struct callout_handle timeout(timeout_t *func, void *arg, int ticks); void callout_handle_init(struct callout_handle *handle); struct callout_handle handle = CALLOUT_HANDLE_INITIALIZER(&handle) void untimeout(timeout_t *func, void *arg, struct callout_handle handle); void callout_init(struct callout *c, int mpsafe); void callout_init_mtx(struct callout *c, struct mtx *mtx, int flags); void callout_init_rw(struct callout *c, struct rwlock *rw, int flags); int callout_stop(struct callout *c); int callout_drain(struct callout *c); int callout_reset(struct callout *c, int ticks, timeout_t *func, void *arg); int callout_schedule(struct callout *c, int ticks); int callout_pending(struct callout *c); int callout_active(struct callout *c); callout_deactivate(struct callout *c); DESCRIPTION
The function timeout() schedules a call to the function given by the argument func to take place after ticks/hz seconds. Non-positive values of ticks are silently converted to the value '1'. func should be a pointer to a function that takes a void * argument. Upon invocation, func will receive arg as its only argument. The return value from timeout() is a struct callout_handle which can be used in conjunction with the untimeout() function to request that a scheduled timeout be canceled. The timeout() call is the old style and new code should use the callout_*() functions. The function callout_handle_init() can be used to initialize a handle to a state which will cause any calls to untimeout() with that handle to return with no side effects. Assigning a callout handle the value of CALLOUT_HANDLE_INITIALIZER() performs the same function as callout_handle_init() and is provided for use on statically declared or global callout handles. The function untimeout() cancels the timeout associated with handle using the func and arg arguments to validate the handle. If the handle does not correspond to a timeout with the function func taking the argument arg no action is taken. handle must be initialized by a previous call to timeout(), callout_handle_init(), or assigned the value of CALLOUT_HANDLE_INITIALIZER(&handle) before being passed to untimeout(). The behavior of calling untimeout() with an uninitialized handle is undefined. The untimeout() call is the old style and new code should use the callout_*() functions. As handles are recycled by the system, it is possible (although unlikely) that a handle from one invocation of timeout() may match the handle of another invocation of timeout() if both calls used the same function pointer and argument, and the first timeout is expired or canceled before the second call. The timeout facility offers O(1) running time for timeout() and untimeout(). Timeouts are executed from softclock() with the Giant lock held. Thus they are protected from re-entrancy. The functions callout_init(), callout_init_mtx(), callout_init_rw(), callout_stop(), callout_drain(), callout_reset() and callout_schedule() are low-level routines for clients who wish to allocate their own callout structures. The function callout_init() initializes a callout so it can be passed to callout_stop(), callout_drain(), callout_reset() or callout_schedule() without any side effects. If the mpsafe argument is zero, the callout structure is not considered to be ``multi-processor safe''; that is, the Giant lock will be acquired before calling the callout function, and released when the callout function returns. The callout_init_mtx() function may be used as an alternative to callout_init(). The parameter mtx specifies a mutex that is to be acquired by the callout subsystem before calling the callout function, and released when the callout function returns. The following flags may be specified: CALLOUT_RETURNUNLOCKED The callout function will release mtx itself, so the callout subsystem should not attempt to unlock it after the callout function returns. The callout_init_rw() function serves the need of using rwlocks in conujunction with callouts. The function does basically the same as callout_init_mtx() with the possibility of specifying an extra rw argument. The usable lock classes are currently limited to mutexes and rwlocks, because callout handlers run in softclock swi, so they cannot sleep nor acquire sleepable locks like sx or lockmgr. The following flags may be specified: CALLOUT_SHAREDLOCK The lock is only acquired in read mode when running the callout handler. It has no effects when used in conjuction with mtx. The function callout_stop() cancels a callout if it is currently pending. If the callout is pending, then callout_stop() will return a non- zero value. If the callout is not set, has already been serviced or is currently being serviced, then zero will be returned. If the callout has an associated mutex, then that mutex must be held when this function is called. The function callout_drain() is identical to callout_stop() except that it will wait for the callout to be completed if it is already in progress. This function MUST NOT be called while holding any locks on which the callout might block, or deadlock will result. Note that if the callout subsystem has already begun processing this callout, then the callout function may be invoked during the execution of callout_drain(). However, the callout subsystem does guarantee that the callout will be fully stopped before callout_drain() returns. The function callout_reset() first performs the equivalent of callout_stop() to disestablish the callout, and then establishes a new callout in the same manner as timeout(). If there was already a pending callout and it was rescheduled, then callout_reset() will return a non-zero value. If the callout has an associated mutex, then that mutex must be held when this function is called. The function callout_schedule() (re)schedules an existing callout for a new period of time; it is equivalent to calling callout_reset() with the func and arg parameters extracted from the callout structure (though possibly with lower overhead). The macros callout_pending(), callout_active() and callout_deactivate() provide access to the current state of the callout. Careful use of these macros can avoid many of the race conditions that are inherent in asynchronous timer facilities; see Avoiding Race Conditions below for further details. The callout_pending() macro checks whether a callout is pending; a callout is considered pending when a timeout has been set but the time has not yet arrived. Note that once the timeout time arrives and the callout subsystem starts to process this callout, callout_pending() will return FALSE even though the callout function may not have finished (or even begun) executing. The callout_active() macro checks whether a callout is marked as active, and the callout_deactivate() macro clears the callout's active flag. The callout subsys- tem marks a callout as active when a timeout is set and it clears the active flag in callout_stop() and callout_drain(), but it does not clear it when a callout expires normally via the execution of the callout function. Avoiding Race Conditions The callout subsystem invokes callout functions from its own timer context. Without some kind of synchronization it is possible that a call- out function will be invoked concurrently with an attempt to stop or reset the callout by another thread. In particular, since callout func- tions typically acquire a mutex as their first action, the callout function may have already been invoked, but be blocked waiting for that mutex at the time that another thread tries to reset or stop the callout. The callout subsystem provides a number of mechanisms to address these synchronization concerns: 1. If the callout has an associated mutex that was specified using the callout_init_mtx() function (or implicitly specified as the Giant mutex using callout_init() with mpsafe set to FALSE), then this mutex is used to avoid the race conditions. The associated mutex must be acquired by the caller before calling callout_stop() or callout_reset() and it is guaranteed that the callout will be correctly stopped or reset as expected. Note that it is still necessary to use callout_drain() before destroying the callout or its associated mutex. 2. The return value from callout_stop() and callout_reset() indicates whether or not the callout was removed. If it is known that the callout was set and the callout function has not yet executed, then a return value of FALSE indicates that the callout func- tion is about to be called. For example: if (sc->sc_flags & SCFLG_CALLOUT_RUNNING) { if (callout_stop(&sc->sc_callout)) { sc->sc_flags &= ~SCFLG_CALLOUT_RUNNING; /* successfully stopped */ } else { /* * callout has expired and callout * function is about to be executed */ } } 3. The callout_pending(), callout_active() and callout_deactivate() macros can be used together to work around the race conditions. When a callout's timeout is set, the callout subsystem marks the callout as both active and pending. When the timeout time arrives, the callout subsystem begins processing the callout by first clearing the pending flag. It then invokes the callout function without changing the active flag, and does not clear the active flag even after the callout function returns. The mecha- nism described here requires the callout function itself to clear the active flag using the callout_deactivate() macro. The callout_stop() and callout_drain() functions always clear both the active and pending flags before returning. The callout function should first check the pending flag and return without action if callout_pending() returns TRUE. This indi- cates that the callout was rescheduled using callout_reset() just before the callout function was invoked. If callout_active() returns FALSE then the callout function should also return without action. This indicates that the callout has been stopped. Finally, the callout function should call callout_deactivate() to clear the active flag. For example: mtx_lock(&sc->sc_mtx); if (callout_pending(&sc->sc_callout)) { /* callout was reset */ mtx_unlock(&sc->sc_mtx); return; } if (!callout_active(&sc->sc_callout)) { /* callout was stopped */ mtx_unlock(&sc->sc_mtx); return; } callout_deactivate(&sc->sc_callout); /* rest of callout function */ Together with appropriate synchronization, such as the mutex used above, this approach permits the callout_stop() and callout_reset() functions to be used at any time without races. For example: mtx_lock(&sc->sc_mtx); callout_stop(&sc->sc_callout); /* The callout is effectively stopped now. */ If the callout is still pending then these functions operate normally, but if processing of the callout has already begun then the tests in the callout function cause it to return without further action. Synchronization between the callout function and other code ensures that stopping or resetting the callout will never be attempted while the callout function is past the callout_deactivate() call. The above technique additionally ensures that the active flag always reflects whether the callout is effectively enabled or dis- abled. If callout_active() returns false, then the callout is effectively disabled, since even if the callout subsystem is actu- ally just about to invoke the callout function, the callout function will return without action. There is one final race condition that must be considered when a callout is being stopped for the last time. In this case it may not be safe to let the callout function itself detect that the callout was stopped, since it may need to access data objects that have already been destroyed or recycled. To ensure that the callout is completely finished, a call to callout_drain() should be used. RETURN VALUES
The timeout() function returns a struct callout_handle that can be passed to untimeout(). The callout_stop() and callout_drain() functions return non-zero if the callout was still pending when it was called or zero otherwise. HISTORY
The current timeout and untimeout routines are based on the work of Adam M. Costello and George Varghese, published in a technical report entitled Redesigning the BSD Callout and Timer Facilities and modified slightly for inclusion in FreeBSD by Justin T. Gibbs. The original work on the data structures used in this implementation was published by G. Varghese and A. Lauck in the paper Hashed and Hierarchical Timing Wheels: Data Structures for the Efficient Implementation of a Timer Facility in the Proceedings of the 11th ACM Annual Symposium on Operating Systems Principles. The current implementation replaces the long standing BSD linked list callout mechanism which offered O(n) insertion and removal running time but did not generate or require handles for untimeout operations. BSD
August 2, 2008 BSD
Man Page