Linux and UNIX Man Pages

Linux & Unix Commands - Search Man Pages

fruadm(1m) [sunos man page]

fruadm(1M)						  System Administration Commands						fruadm(1M)

NAME
fruadm - prints and updates customer data associated with FRUs SYNOPSIS
/usr/platform/sun4u/sbin/fruadm /usr/platform/sun4u/sbin/fruadm -l /usr/platform/sun4u/sbin/fruadm [-r] path [text] DESCRIPTION
fruadm prints or sets the customer data for Field-Replaceable Units (FRUs). Without arguments, fruadm prints the paths of all FRU ID-capable FRUs (containers) in the system, along with the contents of the customer data record, if present, for each such FRU; for FRUs without customer data, fruadm prints only the container's path. Only a privileged user can create or update data in containers. The privileges required to perform these write operations are hardware dependent. Typically, a default system configuration restricts write operations to the superuser or to the platform-administrator user. OPTIONS
The following options are supported: -l List the system's frutree paths. -r Recursively display or update the data for all containers rooted at the argument path. OPERANDS
The following operands are supported: path A full or partial system frutree path for or under which to print or set the customer data. The first field of each line of output of fruadm -l gives the valid full frutree paths for the system. Paths can include shell meta-characters; such paths should be quoted appropriately for the user's shell. For par- tial paths, the first matching full path is selected for display or update. Without the -r option, the path must be that of a container; with the -r option, all containers (if any) under path will be selected. text Up to 80 characters of text set as the customer data. If the text contains white space or shell metacharacters, it should be quoted appropriately for the user's shell. EXAMPLES
Example 1: Displaying All Customer Data The following example prints all customer data available from FRUs on the system. For containers with no customer data, only the contain- ers' paths will be listed. example% fruadm Example 2: Displaying Customer Data For a Single FRU The following command prints the customer data, if present, for the specified FRU: example% fruadm /frutree/chassis/system-board Example 3: Displaying Customer Data For a Single FRU The following command prints the customer data, if present, for the first mem-module found: example% fruadm mem-module Example 4: Setting Customer Data The following example sets the customer data for a FRU: example# fruadm system-board 'Asset Tag 123456' Example 5: Setting Customer Data The following command sets the customer data for all FRUs under chassis: example# fruadm -r /frutree/chassis "Property of XYZ, Inc." EXIT STATUS
The following exit values are returned: 0 Successful completion. >0 An error occurred. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWfruip.u | +-----------------------------+-----------------------------+ |Interface Stability |Unstable | +-----------------------------+-----------------------------+ SEE ALSO
prtfru(1M), attributes(5) SunOS 5.10 22 Feb 2002 fruadm(1M)

Check Out this Related Man Page

prtdiag(1M)															       prtdiag(1M)

NAME
prtdiag - display system diagnostic information SYNOPSIS
/usr/sbin/prtdiag [-v] [-l] prtdiag displays system configuration and diagnostic information on sun4u and sun4v systems. The diagnostic information lists any failed field replaceable units (FRUs) in the system. The interface, output, and location in the directory hierarchy for prtdiag are uncommitted and subject to change in future releases. prtdiag does not display diagnostic information and environmental status when executed on the Sun Enterprise 10000 server. See the /var/opt/SUNWssp/adm/${SUNW_HOSTNAME}/messages file on the system service processor (SSP) to obtain such information for this server. The following options are supported: -l Log output. If failures or errors exist in the system, output this information to syslogd(1M) only. -v Verbose mode. Displays the time of the most recent AC Power failure, and the most recent hardware fatal error information, and (if applicable) environmental status. The hardware fatal error information is useful to repair and manufacturing for detailed diagnos- tics of FRUs. The following exit values are returned: 0 No failures or errors are detected in the system. 1 Failures or errors are detected in the system. 2 An internal prtdiag error occurred, for example, out of memory. See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWkvm | +-----------------------------+-----------------------------+ |Interface Stability |Unstable* | +-----------------------------+-----------------------------+ *The output is unstable. modinfo(1M), prtconf(1M), psrinfo(1M), sysdef(1M), syslogd(1M), attributes(5), openprom(7D) NOTES
Not all diagnostic and system information is available on every Solaris platforn, and therefore cannot be displayed by prtdiag. On those platforms, further information can be obtained from the System Controller. 29 Aug 2005 prtdiag(1M)
Man Page