TABS(1P) POSIX Programmer's Manual TABS(1P)
PROLOG
This manual page is part of the POSIX Programmer's Manual. The Linux implementation of this interface may differ (consult the correspond-
ing Linux manual page for details of Linux behavior), or the interface may not be implemented on Linux.
NAME
tabs -- set terminal tabs
SYNOPSIS
tabs [-n|-a|-a2|-c|-c2|-c3|-f|-p|-s|-u] [-T type]
tabs [-T type] n[[sep[+]n]...]
DESCRIPTION
The tabs utility shall display a series of characters that first clears the hardware terminal tab settings and then initializes the tab
stops at the specified positions and optionally adjusts the margin.
The phrase ``tab-stop position N'' shall be taken to mean that, from the start of a line of output, tabbing to position N shall cause the
next character output to be in the (N+1)th column position on that line. The maximum number of tab stops allowed is terminal-dependent.
It need not be possible to implement tabs on certain terminals. If the terminal type obtained from the TERM environment variable or -T
option represents such a terminal, an appropriate diagnostic message shall be written to standard error and tabs shall exit with a status
greater than zero.
OPTIONS
The tabs utility shall conform to the Base Definitions volume of POSIX.1-2008, Section 12.2, Utility Syntax Guidelines, except for various
extensions: the options -a2, -c2, and -c3 are multi-character.
The following options shall be supported:
-n Specify repetitive tab stops separated by a uniform number of column positions, n, where n is a single-digit decimal number. The
default usage of tabs with no arguments shall be equivalent to tabs -8. When -0 is used, the tab stops shall be cleared and no
new ones set.
-a 1,10,16,36,72
Assembler, applicable to some mainframes.
-a2 1,10,16,40,72
Assembler, applicable to some mainframes.
-c 1,8,12,16,20,55
COBOL, normal format.
-c2 1,6,10,14,49
COBOL, compact format (columns 1 to 6 omitted).
-c3 1,6,10,14,18,22,26,30,34,38,42,46,50,54,58,62,67
COBOL compact format (columns 1 to 6 omitted), with more tabs than -c2.
-f 1,7,11,15,19,23
FORTRAN
-p 1,5,9,13,17,21,25,29,33,37,41,45,49,53,57,61
PL/1
-s 1,10,55
SNOBOL
-u 1,12,20,44
Assembler, applicable to some mainframes.
-T type Indicate the type of terminal. If this option is not supplied and the TERM variable is unset or null, an unspecified default ter-
minal type shall be used. The setting of type shall take precedence over the value in TERM.
OPERANDS
The following operand shall be supported:
n[[sep[+]n]...]
A single command line argument that consists of one or more tab-stop values (n) separated by a separator character (sep) which is
either a <comma> or a <blank> character. The application shall ensure that the tab-stop values are positive decimal integers in
strictly ascending order. If any tab-stop value (except the first one) is preceded by a <plus-sign>, it is taken as an increment
to be added to the previous value. For example, the tab lists 1,10,20,30 and "110+10+10" are considered to be identical.
STDIN
Not used.
INPUT FILES
None.
ENVIRONMENT VARIABLES
The following environment variables shall affect the execution of tabs:
LANG Provide a default value for the internationalization variables that are unset or null. (See the Base Definitions volume of
POSIX.1-2008, Section 8.2, Internationalization Variables for the precedence of internationalization variables used to determine
the values of locale categories.)
LC_ALL If set to a non-empty string value, override the values of all the other internationalization variables.
LC_CTYPE Determine the locale for the interpretation of sequences of bytes of text data as characters (for example, single-byte as opposed
to multi-byte characters in arguments).
LC_MESSAGES
Determine the locale that should be used to affect the format and contents of diagnostic messages written to standard error.
NLSPATH Determine the location of message catalogs for the processing of LC_MESSAGES.
TERM Determine the terminal type. If this variable is unset or null, and if the -T option is not specified, an unspecified default
terminal type shall be used.
ASYNCHRONOUS EVENTS
Default.
STDOUT
If standard output is a terminal, the appropriate sequence to clear and set the tab stops may be written to standard output in an unspeci-
fied format. If standard output is not a terminal, undefined results occur.
STDERR
The standard error shall be used only for diagnostic messages.
OUTPUT FILES
None.
EXTENDED DESCRIPTION
None.
EXIT STATUS
The following exit values shall be returned:
0 Successful completion.
>0 An error occurred.
CONSEQUENCES OF ERRORS
Default.
The following sections are informative.
APPLICATION USAGE
This utility makes use of the terminal's hardware tabs and the stty tabs option.
This utility is not recommended for application use.
Some integrated display units might not have escape sequences to set tab stops, but may be set by internal system calls. On these termi-
nals, tabs works if standard output is directed to the terminal; if output is directed to another file, however, tabs fails.
EXAMPLES
None.
RATIONALE
Consideration was given to having the tput utility handle all of the functions described in tabs. However, the separate tabs utility was
retained because it seems more intuitive to use a command named tabs than tput with a new option. The tput utility does not support setting
or clearing tabs, and no known historical version of tabs supports the capability of setting arbitrary tab stops.
The System V tabs interface is very complex; the version in this volume of POSIX.1-2008 has a reduced feature list, but many of the fea-
tures omitted were restored as part of the XSI option even though the supported languages and coding styles are primarily historical.
There was considerable sentiment for specifying only a means of resetting the tabs back to a known state--presumably the ``standard'' of
tabs every eight positions. The following features were omitted:
* Setting tab stops via the first line in a file, using --file. Since even the SVID has no complete explanation of this feature, it is
doubtful that it is in widespread use.
In an early proposal, a -t tablist option was added for consistency with expand; this was later removed when inconsistencies with the his-
torical list of tabs were identified.
Consideration was given to adding a -p option that would output the current tab settings so that they could be saved and then later
restored. This was not accepted because querying the tab stops of the terminal is not a capability in historical terminfo or termcap facil-
ities and might not be supported on a wide range of terminals.
FUTURE DIRECTIONS
None.
SEE ALSO
expand, stty, tput, unexpand
The Base Definitions volume of POSIX.1-2008, Chapter 8, Environment Variables, Section 12.2, Utility Syntax Guidelines
COPYRIGHT
Portions of this text are reprinted and reproduced in electronic form from IEEE Std 1003.1, 2013 Edition, Standard for Information Technol-
ogy -- Portable Operating System Interface (POSIX), The Open Group Base Specifications Issue 7, Copyright (C) 2013 by the Institute of
Electrical and Electronics Engineers, Inc and The Open Group. (This is POSIX.1-2008 with the 2013 Technical Corrigendum 1 applied.) In the
event of any discrepancy between this version and the original IEEE and The Open Group Standard, the original IEEE and The Open Group Stan-
dard is the referee document. The original Standard can be obtained online at http://www.unix.org/online.html .
Any typographical or formatting errors that appear in this page are most likely to have been introduced during the conversion of the source
files to man page format. To report such errors, see https://www.kernel.org/doc/man-pages/reporting_bugs.html .
IEEE
/The Open Group 2013 TABS(1P)