pcie_pci(7D) Devices pcie_pci(7D)NAME
pcie_pci - PCI Express bridge nexus driver
DESCRIPTION
The pcie_pci nexus driver is used on X64 servers for PCI Express bridge class devices including PCI Express root ports which are imple-
mented as virtual bridges and PCI Express to PCI/PCI-X bridges.
The pcie_pci driver is compliant with the PCI Express Base, Revision 1.0a specification and supports Base line PCI Express error handling
and PCI Express Hot Plug.
FILES
/platform/i86pc/kernel/drv/pcie_pci
32-bit ELF kernel module.
/platform/i86pc/kernel/drv/amd64/pcie_pci
64-bit ELF kernel module.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+------------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+------------------------------+
|Architecture |x64 PCI Express-based systems |
+-----------------------------+------------------------------+
|Availability |SUNWcakr.i |
+-----------------------------+------------------------------+
SEE ALSO attributes(5), pcie(4), npe(7D)
PCI Express Base Specification v1.0a --2003
Writing Device Drivers
IEEE 1275 PCI Bus Binding -- 1998
http://playground.sun.com/1275/bindings/pci/pci-express.txt
SunOS 5.11 12 Oct 2005 pcie_pci(7D)
Check Out this Related Man Page
ARCMSR(4) BSD Kernel Interfaces Manual ARCMSR(4)NAME
arcmsr -- Areca Technology Corporation SATA/SAS RAID controller
SYNOPSIS
arcmsr* at pci? dev ? function ?
DESCRIPTION
The arcmsr driver provides support for the PCI-X and PCI Express RAID controllers from Areca Technology Corporation:
- ARC-1110 PCI-X 4 Port SATA RAID Controller
- ARC-1110ML PCI-X 4 Port SATA RAID Controller
- ARC-1120 PCI-X 8 Port SATA RAID Controller
- ARC-1120ML PCI-X 8 Port SATA RAID Controller
- ARC-1130 PCI-X 12 Port SATA RAID Controller
- ARC-1130ML PCI-X 12 Port SATA RAID Controller
- ARC-1160 PCI-X 16 Port SATA RAID Controller
- ARC-1160ML PCI-X 16 Port SATA RAID Controller
- ARC-1170 PCI-X 24 Port SATA RAID Controller
- ARC-1200 Rev A PCI Express 2 Port SATA RAID Controller
- ARC-1202 PCI Express 2 Port SATA RAID Controller
- ARC-1210 PCI Express 4 Port SATA RAID Controller
- ARC-1220 PCI Express 8 Port SATA RAID Controller
- ARC-1230 PCI Express 12 Port SATA RAID Controller
- ARC-1230ML PCI Express 12 Port SATA RAID Controller
- ARC-1231ML PCI Express 12 Port SATA RAID Controller
- ARC-1260 PCI Express 16 Port SATA RAID Controller
- ARC-1260ML PCI Express 16 Port SATA RAID Controller
- ARC-1261ML PCI Express 16 Port SATA RAID Controller
- ARC-1280 PCI Express 24 Port SATA RAID Controller
- ARC-1280ML PCI Express 24 Port SATA RAID Controller
- ARC-1680 PCI Express 8 Port SAS RAID Controller
- ARC-1680LP PCI Express 8 Port SAS RAID Controller
- ARC-1680i PCI Express 8 Port SAS RAID Controller
- ARC-1680x PCI Express 8 Port SAS RAID Controller
- ARC-1681 PCI-X 8 Port SAS RAID Controller
These controllers support RAID levels 0, 1, 1E, 3, 5, 6, and JBOD using either SAS or SATA II drives.
arcmsr supports management and monitoring of the controller through the bioctl(8) and envstat(8) commands.
Please note, however, that to use some features that require special privileges, such as creating/removing hot-spares, pass-through disks or
RAID volumes will require to have the password disabled in the firmware; otherwise a Permission denied error will be reported by bioctl(8).
When a RAID 1 or 1+0 volume is created, either through the bioctl(8) command or controller's firmware, the volume won't be accessible until
the initialization is done. A way to get access to the sd(4) device that corresponds to that volume without rebooting, is to issue the fol-
lowing command (once the initialization is finished):
$ scsictl scsibus0 scan any any
The arcmsr driver will also report to the kernel log buffer any error that might appear when handling firmware commands, such as used by the
bioctl(8) command.
EVENTS
The arcmsr driver is able to send events to powerd(8) if a volume or any drive connected to the volume is not online. The state-changed
event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens.
SEE ALSO intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8), scsictl(8)HISTORY
The arcmsr driver first appeared in NetBSD 5.0.
AUTHORS
The arcmsr driver was originally written for OpenBSD by David Gwynne. It was ported to NetBSD and extended by Juan Romero Pardines.
BSD March 3, 2008 BSD