SMP_ZONE_LOCK(8)						     SMP_UTILS							  SMP_ZONE_LOCK(8)

NAME
smp_zone_lock - invoke ZONE LOCK SMP function SYNOPSIS
smp_zone_lock [--expected=EX] [--fpass=FP] [--help] [--hex] [--inactivity=TL] [--interface=PARAMS] [--password=PA] [--raw] [--sa=SAS_ADDR] [--verbose] [--version] SMP_DEVICE[,N] DESCRIPTION
Sends a SAS Management Protocol (SMP) ZONE LOCK function request to a SMP target. The SMP target is identified by the SMP_DEVICE and the --sa=SAS_ADDR. Depending on the interface, the SAS_ADDR may be deduced from the SMP_DEVICE. The mpt interface uses SMP_DEVICE to identify a HBA (an SMP initiator) and needs the additional ,N to differentiate between HBAs if there are multiple present. OPTIONS
Mandatory arguments to long options are mandatory for short options as well. -E, --expected=EX set the 'expected expander change count' field in the SMP request. The value EX is from 0 to 65535 inclusive with 0 being the default value. When EX is greater than zero then if the value doesn't match the expander change count of the SMP target (i.e. the expander) when the request arrives then the target ignores the request and sets a function result of "invalid expander change count" in the response. -F, --fpass=FP where FP is the name of a file which contains the password. The password may be in ASCII in which case it is on one line surrounded by either single quotes are double quotes. Alternatively the password may be given in ASCII hexadecimal; either as bytes separated by space, tab, comma or newline, or as longer strings of hexadecimal bytes in which every 2 digits represents a byte. Empty lines and those starting with "#" are ignored. -h, --help output the usage message then exit. -H, --hex output the response (less the CRC field) in hexadecimal. -i, --inactivity=TL sets the zone lock inactivity time limit to TL which has units of 100 milliseconds. The default value is 0 which implies no time limit. -I, --interface=PARAMS interface specific parameters. In this case "interface" refers to the path through the operating system to the SMP initiator. See the smp_utils man page for more information. -P, --password=PA where PA is the zone manager password which may be up to 32 bytes long. This option cannot be give together with the --fpass=FP option. The default password is 32 NULLs (zero bytes) and PA is padded with NULLs to the right (to make it 32 bytes long in the request). -r, --raw send the response (less the CRC field) to stdout in binary. All error messages are sent to stderr. -s, --sa=SAS_ADDR specifies the SAS address of the SMP target device. The mpt interface needs this option and it will typically be an expander's SAS address. The SAS_ADDR is in decimal but most SAS addresses are shown in hexadecimal. To give a number in hexadecimal either prefix it with '0x' or put a trailing 'h' on it. -v, --verbose increase the verbosity of the output. Can be used multiple times. -V, --version print the version string and then exit. CONFORMING TO
The SMP ZONE LOCK function was introduced in SAS-2 . AUTHORS
Written by Douglas Gilbert. REPORTING BUGS
Report bugs to <dgilbert at interlog dot com>. COPYRIGHT
Copyright (C) 2011 Douglas Gilbert This software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR- POSE. SEE ALSO
smp_utils, smp_zone_activate, smp_zone_unlock, smp_ena_dis_zoning(smp_utils) smp_utils-0.96 June 2011 SMP_ZONE_LOCK(8)

Check Out this Related Man Page

SMP_ENA_DIS_ZONING(8)						     SMP_UTILS						     SMP_ENA_DIS_ZONING(8)

NAME
smp_ena_dis_zoning - invoke ENABLE DISABLE ZONING SMP function SYNOPSIS
smp_ena_dis_zoning [--disable] [--ena-dis=ED] [--expected=EX] [--help] [--hex] [--interface=PARAMS] [--raw] [--sa=SAS_ADDR] [--save=SAV] [--verbose] [--version] SMP_DEVICE[,N] DESCRIPTION
Sends a SAS Management Protocol (SMP) ENABLE DISABLE ZONING function request to a SMP target. The SMP target is identified by the SMP_DEVICE and the --sa=SAS_ADDR. Depending on the interface, the SAS_ADDR may be deduced from the SMP_DEVICE. The mpt interface uses SMP_DEVICE to identify a HBA (an SMP initiator) and needs the additional ,N to differentiate between HBAs if there are multiple present. If neither --disable nor --ena-dis=ED options are given then enable zoning (i.e. "--ena-dis=1") is assumed. This function does not change the state of the current zoning enabled flag (as seen in the REPORT GENERAL response). Such a state change will occur on a subsequent invocation of the ZONE ACTIVATE function. OPTIONS
Mandatory arguments to long options are mandatory for short options as well. -d, --disable set the 'enable disable zoning' field in the SMP request to 2 which will disable zoning. -e, --ena-dis=ED set the 'enable disable zoning' field in the SMP request. ED may take these values: 0 for no change, 1 for enable zoning (default) and 2 for disable zoning. If this option and the --disable option are both given then they cannot contradict one another. -E, --expected=EX set the 'expected expander change count' field in the SMP request. The value EX is from 0 to 65535 inclusive with 0 being the default value. When EX is greater than zero then if the value doesn't match the expander change count of the SMP target (i.e. the expander) when the request arrives then the target ignores the request and sets a function result of "invalid expander change count" in the response. -h, --help output the usage message then exit. -H, --hex output the response (less the CRC field) in hexadecimal. -I, --interface=PARAMS interface specific parameters. In this case "interface" refers to the path through the operating system to the SMP initiator. See the smp_utils man page for more information. -r, --raw send the response (less the CRC field) to stdout in binary. All error messages are sent to stderr. -s, --sa=SAS_ADDR specifies the SAS address of the SMP target device. The mpt interface needs this option and it will typically be an expander's SAS address. The SAS_ADDR is in decimal but most SAS addresses are shown in hexadecimal. To give a number in hexadecimal either prefix it with '0x' or put a trailing 'h' on it. -S, --save=SAV set the 'save' field in the SMP request. SAV may take these values: 0 for updating the shadow values (default), 1 for updating the saved values, 2 for updating shadow values and if available the saved values, 3 for updating both saved and shadow values. -v, --verbose increase the verbosity of the output. Can be used multiple times. -V, --version print the version string and then exit. CONFORMING TO
The SMP ENABLE DISABLE ZONING function was introduced in SAS-2 . AUTHORS
Written by Douglas Gilbert. REPORTING BUGS
Report bugs to <dgilbert at interlog dot com>. COPYRIGHT
Copyright (C) 2011 Douglas Gilbert This software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR- POSE. SEE ALSO
smp_utils, smp_lock, smp_zone_activate, smp_zone_unlock(smp_utils) smp_utils-0.96 June 2011 SMP_ENA_DIS_ZONING(8)