Query: modbus_receive
OS: debian
Section: 3
Format: Original Unix Latex Style Formatted with HTML and a Horizontal Scroll Bar
MODBUS_RECEIVE(3) Libmodbus Manual MODBUS_RECEIVE(3)NAMEmodbus_receive - receive a indication requestSYNOPSISint modbus_receive(modbus_t *ctx, uint8_t *req);DESCRIPTIONThe modbus_receive() function shall receive an indication request from the socket of the context ctx. This function is used by Modbus slave/server to receive and analyze indication request sent by the masters/clients. If you need to use another socket or file descriptor than the one defined in the context ctx, see the function modbus_set_socket(3).RETURN VALUEThe modbus_receive() function shall store the indication request in req and return the request length if sucessful. Otherwise it shall return -1 and set errno.SEE ALSOmodbus_set_socket(3) modbus_reply(3)AUTHORSThe libmodbus documentation was written by Stephane Raimbault <stephane.raimbault@gmail.com[1]>NOTES1. stephane.raimbault@gmail.com mailto:stephane.raimbault@gmail.com libmodbus 3.0.3 05/26/2012 MODBUS_RECEIVE(3)
| Related Man Pages |
|---|
| modbus_new_tcp(3) - debian |
| modbus_send_raw_request(3) - debian |
| modbus_set_response_timeout(3) - debian |
| modbus_set_slave(3) - debian |
| modbus_write_and_read_registers(3) - debian |
| Similar Topics in the Unix Linux Community |
|---|
| Introduction |
| Detecting unused variables... |
| One instance of comparing grep and awk |
| My first PERL incarnation... Audio Oscillograph |