net-snmp-config --create-snmpv3-user snmpengineID

 
Thread Tools Search this Thread
Special Forums UNIX and Linux Applications Infrastructure Monitoring net-snmp-config --create-snmpv3-user snmpengineID
# 1  
Old 09-09-2009
net-snmp-config --create-snmpv3-user snmpengineID

Solaris 10 -- I created SNMPv3 users with net-snmp-config --create-snmpv3-user command. I am using HP Network Node Manager's SNMPv3 Smart Plugin to serve as the SNMP management server. Some SNMPv3 users were automatically created with the same snmpengineID. This causes NNM's brassagt proxy to timeout on any request from a snmp agent once another agent with an identical snmpengineID establishes communication. HP told me to contact the vendor of these devices for information on how to change the snmpengineID. Does anyone know what would cause the duplicate ID's, or how to change the engineID's

Thanks in advance!
Login or Register to Ask a Question

Previous Thread | Next Thread

5 More Discussions You Might Find Interesting

1. HP-UX

Net-snmp 5.7.2 on HP-UX 11.31

Hi All, I have an issue with net-snmp communication from a monitoring server to HP UX server. Following are the details HP - UX server : 172.16.184.34 Monitoring Server : 172.16.5.57 (Solarwinds Application)I'm running HP-UX's snmp on udp port 161 and net-snmp on udp 1161. ... (0 Replies)
Discussion started by: maverick_here
0 Replies

2. Solaris

Disable SNMP v1/2 authentification and use SNMPv3 authentification

Hello everyone, Can anyone help me to disable SNMP v1/2 authentification on Solaris 10 and use SNMP v3 authentification ? I have SNMPv3 installed on my Solaris but the tool we use to scan vulnerabilities still show that there is a problem whith authentification version. Does it mean that... (1 Reply)
Discussion started by: adilyos
1 Replies

3. AIX

Net snmp bug

Hi Admins, I have installed net-snmp 5.5 binary in AIX 5.5 box and configured using snmpconf command.When i run ./snmpd -f -Lo -c /etc/snmpd.conf m getting below error. nlist err: neither proc nor _proc found After surfing i came to know the same is a bug.Please anyone tell me how to... (3 Replies)
Discussion started by: newaix
3 Replies

4. Shell Programming and Scripting

parsing config file to create new config files

Hi, I want to use a config file as the base file and parse over the values of country and city parameters in the config file and generate separate config files as explained below. I will be using the config file as mentioned below: (config.txt) country:a,b city:1,2 type:b1... (1 Reply)
Discussion started by: clazzic
1 Replies

5. UNIX for Dummies Questions & Answers

net-snmp

Does anybody know where I can get net-snmp for compaq tru64 V4.0G? I am having a difficult time locating it. Can it run on tru64 V4.0G? (2 Replies)
Discussion started by: jalburger
2 Replies
Login or Register to Ask a Question
SNMP-UPS(8)							    NUT Manual							       SNMP-UPS(8)

NAME
snmp-ups - Multi-MIB Driver for SNMP UPS equipment NOTE
This man page only documents the hardware-specific features of the snmp-ups driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
The snmp-ups driver automatically detects and supports a wide range of devices by loading various MIBS: ietf:: UPS that is RFC 1628 (UPS MIB) compliant, e.g. MGE UPS SYSTEMS, Liebert, perhaps others (default) mge MGE UPS SYSTEMS and MGE Office Protection Systems devices with SNMP cards (ref 66062, 66045, 66074 and 66244) apcc APC AP9605, AP9606, AP9617, and AP9618 APC network management cards, as well as any others supporting the APC POWERNET MIB netvision Socomec Sicon UPS with Netvision Web/SNMP management card/external box pw Powerware devices with ConnectUPS SNMP cards aphel_genesisII Eaton Powerware ePDU Monitored aphel_revelation Eaton Powerware ePDU Managed raritan Various Raritan PDUs baytech Various BayTech PDUs cpqpower HP/Compaq AF401A management card, perhaps others cyberpower Cyberpower RMCARD201. Should also support RMCARD100 (net version), RMCARD202 and RMCARD301 EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5): mibs=name Set MIB compliance (default=auto, allowed entries: refer to the above SUPPORTED HARDWARE). With "auto", the driver will try a select set of SNMP objects until it finds one that the device responds to. community=name Set community name (default = public). Note that you require a RW community name to change UPS settings (as for a powerdown). snmp_version=version Set SNMP version (default = v1, the other allowed value is v2c) pollfreq=value Set polling frequency in seconds, to reduce network flow (default=30) notransferoids Disable the monitoring of the low and high voltage transfer OIDs in the hardware. This will remove input.transfer.low and input.transfer.high from the list of variables. This should only be used on APCC Symmetra equipment which has strangeness in the three-phase power reporting. secLevel=value Set the securityLevel used for SNMPv3 messages (default=noAuthNoPriv, allowed: authNoPriv,authPriv) secName=value Set the securityName used for authenticated SNMPv3 messages (no default) authPassword=value Set the authentication pass phrase used for authenticated SNMPv3 messages (no default) privPassword=value Set the privacy pass phrase used for encrypted SNMPv3 messages (no default) authProtocol=value Set the authentication protocol (MD5 or SHA) used for authenticated SNMPv3 messages (default=MD5) privProtocol=value Set the privacy protocol (DES or AES) used for encrypted SNMPv3 messages (default=DES) REQUIREMENTS
You will need to install the Net-SNMP package from http://www.net-snmp.org/ before building this driver. SNMP v3 also requires OpenSSL support from http://www.openssl.org. LIMITATION
Shutdown This driver does not provide a proper upsdrv_shutdown() function. There probably never will be one, since at the time this script should run (near the end of the system halt script), there will be no network capabilities anymore. Probably the only way to shutdown an SNMP UPS is by sending it a shutdown with delay command through upscmd(8) and hope for the best that the system will have finished shutting down before the power is cut. INSTALLATION
This driver is only built if the Net-SNMP development files are present on the system. You can also force it to be built by using "configure --with-snmp=yes" before calling make. IMPLEMENTATION
The hostname of the UPS is specified with the "port" value in ups.conf, i.e.: [snmpv1] driver = snmp-ups port = snmp-ups.example.com community = public snmp_version = v1 mibs = ietf pollfreq = 15 desc = "Example SNMP v1 device" [snmpv3] driver = snmp-ups port = 166.99.224.132 mibs = mge secLevel = authPriv secName = mysecurityname authPassword = myauthenticationpassphrase privPassword = myprivatepassphrase desc = "Example SNMP v3 device, with the highest security level" AUTHORS
Arnaud Quette, Dmitry Frolov Sponsored by Eaton http://www.eaton.com and originally by MGE UPS SYSTEMS http://www.mgeups.com/ SEE ALSO
The core driver: nutupsdrv(8) NUT SNMP Protocols Library Available at: http://www.networkupstools.org/protocols/snmp/ Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 SNMP-UPS(8)