Server and OS:
# uname -a
HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license
# model
9000/800/L3000-7x
But now I have only 1 disk active (Other 2 removed ).. But am failed to remove the red marked disk from VG00 .. .
Here's the present status
# lvlnboot -v
lvlnboot: Couldn't query physical volume "/dev/dsk/c2t0d0":
The specified path does not correspond to physical volume attached to
this volume group
Now I want to remove the above VG error as something expecting like this .
## Have tried below
# vgreduce vg00 /dev/dsk/c2t0d0
vgreduce: Couldn't query physical volume "/dev/dsk/c2t0d0":
The specified path does not correspond to physical volume attached to
this volume group
# mv /etc/lvmtab /etc/lvmtab_
# vgscan -av
# vgchange -a y /dev/vg00
vgchange: Volume group "/dev/vg00" does not exist in the "/etc/lvmtab" file.
Did your try the following?
Extract from man vgreduce:
Quote:
-f vg_name force reduction of missing physical volume(s) in a
given volume group. vgreduce obtains the name of
each physical volume (PV) belonging to the volume
group. It then reads the kernel PV structures to
work out which PVs are missing. PVs which are
missing will be candidates for removal. If all
the physical extents on the missing PV are free
then it will be removed from the volume group.
Otherwise vgreduce will report the physical to
logical extent mapping. For missing PVs which
have extents in use, you must free up all the
extents by using lvreduce or lvremove and re-run
vgreduce with the -f option. This option is most
commonly used when the vgdisplay(1M) command shows
"Cur PV" higher than "Act PV" and all of the PVs
belonging to the volume group are attached. This
option only works on PVs and not on links. See
the -l option for details on handling missing
links.
Please post the output from:
And explain in detail how you got into this situation. If this is another attempt at cloning without using a HP-UX Ignite backup or a cold build, please give the history with every command typed.
No idea why you persist in trying to make a valid system from trying to repair broken mirrors. It is not possible.
Last edited by methyl; 03-22-2012 at 06:37 PM..
Reason: spelin
I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply)
-> show faulty
Target ... (1 Reply)
Hi Guys,
One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine
But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Hi
I have one of the disk missing in my NIMVG. My doubt is can I remove this hdisk2 online ? few of the file systems seems to be spread over 7 PV's. that's why i'm worried. Can someone suggest if I can replace this disk online. Also how to check if there is some data present in hdisk2 alone... (2 Replies)
Hello,
I'm new to this forum and as you will see from my question I'm new to UNIX as well.
One of our costumers has HP rx4640 running on UNIX with two 300GB hot-swappable disks that are mirrored. They reported to us that one of the disks is faulty and they want us to take care of it. Below is... (16 Replies)
Requirement to remove a faulty mirrored disk from hp-ux LVM
<root@pdwp1s>/etc # vgdisplay -v /dev/vg00
vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0":
The specified path does not correspond to physical volume attached to
this volume group
vgdisplay: Warning: couldn't... (9 Replies)
Hi,
Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great.
# uname –a
SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4
#df -k
Filesystem kbytes used... (3 Replies)
Hi Experts,
I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics.
pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D
SSA160 Physical Disk Drive ( MB)
Is there a way to stop this... (2 Replies)
Hello once again seeking your help,
I have a mirrored disk and need to unmirror it to mount it as a new file system (/export) but could not find the correct steps to do it with out affecting the original disk.
can anybody point me out on how to get this done.
Thanks!! (3 Replies)
Hello,
I've got 2 system disks (hdisk0 and hdisk1) in the mirror (RAID1) on AIX 5.3. Since the hdisk1 makes some troubles, we want to replace it with the new one. How can I disable this hdisk1 disk and prepare the mirror to use the new physical disk? As far as I know, I must remove disk from the... (3 Replies)
I have a bogus disk that keeps showing up as failed from vxdisk list
- - disk hpdg failed was:c2t0d11s2
There isnt any c2 devices on the system:
# ls /dev/dsk/c2*
/dev/dsk/c2*: No such file or directory
# ls /dev/rdsk/c2*
/dev/rdsk/c2*: No such file or... (3 Replies)