ISS Technology Brief HP BladeSystem C7000 Enclosure, 3rd edition; Part 1


 
Thread Tools Search this Thread
Operating Systems HP-UX HP Server News and Podcasts RSS ISS Technology Brief HP BladeSystem C7000 Enclosure, 3rd edition; Part 1
# 1  
Old 01-05-2009
ISS Technology Brief HP BladeSystem C7000 Enclosure, 3rd edition; Part 1

Part one of a podcast of the ISS Technology Brief HP BladeSystem C7000 Enclosure, 3rd edition. This technology brief provides an overview of the HP BladeSystem c7000 Enclosure, including Thermal Logic power and cooling technologies and interconnect options.

More...
Login or Register to Ask a Question

Previous Thread | Next Thread

2 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

I want replace string <enclosure>&#x22;</enclosure> with <enclosure>&#x5e;</enclosure> in xml

I have xml files with with extension .ktr in subfolders i want to replace the string <enclosure>&#x22;</enclosure> with <enclosure>&#x5e;</enclosure> i have written logic but it is not working correctly sed -i '' 's#<enclosure>&\#x22;</enclosure>#<enclosure>&\#x5e;</enclosure>#g' *.ktr ... (3 Replies)
Discussion started by: reddy12
3 Replies

2. Shell Programming and Scripting

Learning Perl 3rd Edition

Does anyone know where I might be able to download the exercises from the learning perl 3rd edition book. Any URL's would be valuable! Thanks:confused: (1 Reply)
Discussion started by: bilal_aa
1 Replies
Login or Register to Ask a Question
SG_SAFTE(8)							     SG3_UTILS							       SG_SAFTE(8)

NAME
sg_safte - access SCSI Accessed Fault-Tolerant Enclosure (SAF-TE) device SYNOPSIS
sg_safte [--config] [--devstatus] [--encstatus] [--flags] [--help] [--hex] [--insertions] [--raw] [--usage] [--verbose] [--version] DEVICE DESCRIPTION
Fetches enclosure status (via a SCSI READ BUFFER command). The DEVICE should be a SAF-TE device which may be a storage array controller (INQUIRY peripheral device type 0xc) or a generic processor device (INQUIRY peripheral device type 0x3). If no options are given (only the DEVICE argument) then the overall enclosure status as reported by the option --config (R)is reported. OPTIONS
Arguments to long options are mandatory for short options as well. The options are arranged in alphabetical order based on the long option name. -c, --config will issues a Read Enclosure Configuration (R)(READ BUFFER ID 0) cdb to the device, which returns a list of the enclosure hardware resources. -d, --devstatus will issue a Read Device Slot Status (R)(READ BUFFER ID 4) cdb to the device, which returns information about the current state of each drive or slot. -s, --encstatus will issue a Read Enclosure Status (R)(READ BUFFER ID 1) cdb to the device, which returns the operational state of the components. -f, --flags will issue a Read Global Flags (R)(READ BUFFER ID 5) cdb to the device, which read the most recent state of the global flags of the RAID processor device. -h, --help output the usage message then exit. -H, --hex output the response to a READ BUFFER command in ASCII hex to stdout. If used once, output the response to the first READ BUFFER com- mand (i.e. with buffer_id=0). This should be the enclosure configuration. If used twice (or more often), the response to subsequent READ BUFFER commands is output. -i, --insertions will issue a Read Device Insertions (R)(READ BUFFER ID 3) cdb to the device, which returns information about the number of times devices have been inserted whilst the RAID system was powered on. -r, --raw output the response to a READ BUFFER command in binary to stdout. If used once, output the response to the first READ BUFFER command (i.e. with buffer_id=0). This should be the enclosure configuration. If used twice (or more often), the response to subsequent READ BUFFER commands is output. -u, --usage will issue a Read Usage Statistics (R)(READ BUFFER ID 2) cdb to the device, which returns the information on total usage time and number of power-on cycles of the RAID device. -v, --verbose increase the level of verbosity, (i.e. debug output). -V, --version print the version string and then exit. NOTES
The implementation is based on the intermediate review document eg as found at http://www.intel.com/design/servers/ipmi/saf-te.htm As the specification was never finalized this document serves as the de-facto standard. Similar functionality is provided by SPC-4 SCSI Enclosure Services devices (Peripheral device type 0xd), which can be queried with the sg_ses utility. EXAMPLES
To view the configuration: sg_safte /dev/sg1 To view the device slot status: sg_safte --devstatus /dev/sg1 EXIT STATUS
The exit status of sg_safte is 0 when it is successful. Otherwise see the sg3_utils(8) man page. AUTHORS
Written by Hannes Reinecke and Douglas Gilbert. REPORTING BUGS
Report bugs to <dgilbert at interlog dot com>. COPYRIGHT
Copyright (C) 2004-2012 Hannes Reinecke and Douglas Gilbert This software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR- POSE. SEE ALSO
sg_inq, sg_ses (in sg3_utils package); safte-monitor (internet) sg3_utils-1.35 November 2012 SG_SAFTE(8)