you didn't connect client VSCSI device to a server VSCSI device.
you connected client VSCSI device to wrong server VSCSI device.
you connected client VSCSI device to the right server VSCSI device, but made a mistake in a device definition (wrong LPAR ID).
On server4 side:
On VIOS side:
On HMC side:
Thanks, I just started this job a little over a month ago and just trying to make the companies environment healthy, "or trying, HA", don't know who set this up and when..
I don't know the name of your managed system. It is the IBM server, where all your LPARs reside. You can look which managed systems you have using the command lssyscfg -r sys -F name
I don't know the name of your managed system. It is the IBM server, where all your LPARs reside. You can look which managed systems you have using the command lssyscfg -r sys -F name
I am unable to find the IP to hmc...
Is there a way of using chdev -l vscsi1 ..... command to make defined state avaiable?
the command you want is mkdev -l vscsi1 - this was the first command you executed and it didn't help. So you have some problem in your configuration and still have to find it.
Hi everybody,
I have Power5 server with 4 internal hdisks each of 70Gb.
VIOS server was installed via Virtual I/O Server Image Repository on the HMC.
HMC release - 7.7.0
VIOS rootvg installed on 2 disk(these disks merged to one storage pool during VIOS install process),and 2 others hdisks... (2 Replies)
Hello,
When I assigned CDROM from IVM (VIOS) to LPAR and then running cfgmgr i get the following message on the client lpar
#cfgmgr
cfgmgr: 0514-621 WARNING: The following device packages are required for device support but are not currently installed.
devices.vscsi.disk
searching... (0 Replies)
If you're familiar with vscsi mappings thru a VIO Server, you are probably aware, on an AIX 6.1 Client LPAR, that:
print cvai | kdbcan provide useful information to you.... like VIO Server name & vhost #. But, "cvai" does not appear to be part of the Kernel Debugger in AIX 5.3.
My question is... (3 Replies)
Hello,
I have a VIOS System and would like to do mapping some hdisks, hdisk160 until hdisk165 to a vSCSi Adapter. I try to do this in the oem_setup_env like the following:
for i in $(lspv | grep hdisk* | awk {'print $1'};
do
mkdev -V $i -p vhost20
done
There where a mapping with... (4 Replies)
Hi,
I want to change from vscsi to npiv. Is it possible to use both on the same adapter, so we can change the systems one by one, or must we place a second FC adapter in the VIO servers?
Thanks,
Ronald (2 Replies)
Hi All,
I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV.
My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
One of my zone is stuck in down state, not able to boot it or halt it .. not even detach .. is there any way to recover without rebooting the whole system ( global zone ) ? (3 Replies)