Good morning,
Saw this on a system this morning, thought I'd check with this group before calling IBM.
Basically what we have here is a P7 running 6.1 reporting the following in errpt:
LABEL: GOENT_LINK_DOWN
IDENTIFIER: EC0BCCD4
This is for ent4, which is odd because we don't have anything plugged into that port. I tried doing a diag on that and I got an error code of "803-256E: Software error encountered running Diagnostic Application on ent4."
I'm a little worried that this might be indicative of a wonky NIC -- it's the vagueness of the "software error" that's got me concerned. Another possibility is that a fellow admin was doing some analytics on the network connections on this server and that may have blipped ent4, but I thought I'd check with this community and see if anyone's encountered this before.
Thanks all!
Mike
---------- Post updated at 03:55 PM ---------- Previous update was at 10:54 AM ----------
Never mind. Did some closer observation. Seems someone doing some metrics on the networking kicked on en4, sans address. I brought it down and detached it and things seem clear now.
Sorry about the false alarm.