10 More Discussions You Might Find Interesting
1. Ubuntu
Hello!
i am having a ubuntu server with two empty disks and connected software raid1 to it.
I am having /mnt/raid folder which i created to mount it.
SO should i now make a share folder inside that or what? I ama bit confused when a raid is present. (27 Replies)
Discussion started by: tomislav91
27 Replies
2. Ubuntu
Hello,
I installed ubuntu desktop just recently in aim to create a RAID1 configuration using software RAID MDADM.
I have the following configuration as fdisk -l reports:
Disk /dev/sda: 223,6 GiB, 240057409536 bytes, 468862128 sectors
Units: sectors of 1 * 512 = 512 bytes
Sector size... (5 Replies)
Discussion started by: Reol
5 Replies
3. Solaris
Is there an easy, safe way to move the system to RAID1 on sparc solaris 10?
(without reinstalling).
thanks. (6 Replies)
Discussion started by: orange47
6 Replies
4. Linux
Hello,
i'm running a server with two disks in raid1.. it seems that some bad sectors have recently appeared on one of the disks.
Aug 9 08:26:19 linux smartd: Device: /dev/sda, FAILED SMART self-check. BACK UP DATA NOW!
Aug 9 08:26:19 linux smartd: Device: /dev/sda, 2 Currently... (0 Replies)
Discussion started by: TehOne
0 Replies
5. Linux
Hi,
I've been searching for answers for two days and didn't find any definite answers on building RAID1 on SPARC. The main problem was with SILO (Sparc Improved boot LOader): can it boot from RAID partition or not. So I just tried it and it works.
I've done this on Debian, but it should be... (0 Replies)
Discussion started by: Luka
0 Replies
6. Filesystems, Disks and Memory
does anyone k ow the answer to this?
OS solaris 10
using the command raidctl -c c1t0d0 c1t1d0, this took about 4 mins to return to the prompt with "Volume c1t0d0 is created successfully!"
then using format I saw
AVAILABLE DISK SELECTIONS:
0. c1t0d0 <SUN72G cyl 14087 alt 2 hd 24 sec 424>... (1 Reply)
Discussion started by: powerrack
1 Replies
7. UNIX for Advanced & Expert Users
I have a HP proliant ML 570 G3 with two 146GB disk drives mirrored(RAID1+0)
windows server 2003 was installed on that disk.
I will add a disk.(scsi 300GB)
I will install Linux on that additional disk.
I want to create multiple-boot system.
Is it possible?
I wanna know how to create... (0 Replies)
Discussion started by: lifegeek
0 Replies
8. Solaris
I have a Netra T5220 Solaris 10 server with LDoms installed and enabled. RAID1 is enabled in the control domain with the following slices:
d50 -m d51 d52 1
d51 1 1 c1t0d0s5
d52 1 1 c1t1d0s5
d10 -m d11 d12 1
d11 1 1 c1t0d0s0
d12 1 1 c1t1d0s0
d20 -m d21 d22 1
d21 1 1 c1t0d0s1
d22 1 1... (14 Replies)
Discussion started by: StarSol
14 Replies
9. Filesystems, Disks and Memory
I'm setting up a server with software RAID1, and everything is working perfectly, except that when I pull either of the drives, the system completely hangs and has to be rebooted. The computer is a Tyan Transport GX28, which is alleged to have hot-swappable SATA. I can fail a drive and the system... (1 Reply)
Discussion started by: vertigo23
1 Replies
10. UNIX for Dummies Questions & Answers
thank u very much, (1 Reply)
Discussion started by: coralsea
1 Replies
POWERMAN-PDU(8) NUT Manual POWERMAN-PDU(8)
NAME
powerman-pdu - Driver for Powerman PDU
SYNOPSIS
powerman-pdu -h
powerman-pdu -a PDU_NAME [OPTIONS]
Note
This man page only documents the hardware-specific features of the powerman-pdu driver. For information about the core driver, see
nutupsdrv(8).
SUPPORTED HARDWARE
This driver supports a wide range of PDUs through the Powerman project.
This includes various models from APC, Baytech, Cyclades, but also support IPMI and various blade management modules from HP, IBM and Sun.
EXTRA ARGUMENTS
This driver doesn't support any optional settings.
INSTALLATION
This driver is not built by default. You can build it by using "configure --with-powerman=yes".
UPS COMMANDS
The following instant commands (see upscmd(8)) are available for each outlet of the PDU, with X standing for the outlet number:
outlet.X.load.on
Power on the outlet.
outlet.X.load.off
Power off the outlet.
outlet.X.load.cycle
Cycle the outlet (power off then power on, possibly with a delay).
IMPLEMENTATION
The hostname of the Powerman server is specified using the "port" value in ups.conf, i.e.:
[pdu]
driver = powerman-pdu
port = host.example.com:port
The port used to reach powermand is optional if the default port is used.
KNOWN ISSUES
In the current NUT version (2.4.1), ups.status is still exposed, with the value "WAIT". Some other values from the ups collection are also
exposed.
AUTHOR
Arnaud Quette <arnaud.quette@gmail.com>
SEE ALSO
The core driver:
nutupsdrv(8)
Internet resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
The PowerMan home page: http://powerman.sourceforge.net/
Network UPS Tools 05/21/2012 POWERMAN-PDU(8)