Sponsored Content
Operating Systems SCO SCO 5.0.7 driver for HP SmartArray P410i Controller on Proliant DL380 G7? Post 303037238 by jgt on Friday 26th of July 2019 02:07:01 PM
Old 07-26-2019
Go to the sco site xinuos.com and check the certified hardware list.


According to the hardware list, only the P400 controller is supported, and i am pretty sure that the P410 was never supported.

Last edited by jgt; 07-26-2019 at 05:55 PM..
This User Gave Thanks to jgt For This Post:
 

10 More Discussions You Might Find Interesting

1. SCO

ultra 320 scsi raid controller driver for sco 5.0.6

I am facing a problem to install sco 5.0.6 in Dell Power Edge SC1420 which raid controller is ultra 320 scsi raid controller . how/from where to download the ultra 320 scsi raid controller driver for sco 5.0.6. Plz help with any idea karzon (1 Reply)
Discussion started by: karzon
1 Replies

2. SCO

driver needed for hp smartarry p200i sas raid controller

recently we have purchased hp proliant ml350 g5 server and configured raid 5 with hp smartarray p200i sas controller.but i could not found any sas raid controller hp smartarry p200i driver for sco unix 5.0.7 :(.i searched on hp support site,but no use.any one can help. (3 Replies)
Discussion started by: prakrithi
3 Replies

3. UNIX for Dummies Questions & Answers

SCO Openserver 6.0 Insall on HP DL380 serverl

Trying to install Openserver 6.0 on this server which has an integrated Smart Array P400. Install halts with the message ....... "Incorrect Disk Partitioning .........................." I havent yet got to the "divvy" and disk partitioning section of the install section so I am... (2 Replies)
Discussion started by: farmacy
2 Replies

4. SCO

SCO 5.0.7 no root disk controller found error during install

I'm "attempting" to install SCO 5.0.7 on an HP ML370 G4 server and am ready to bash the keyboard with head now. I keep getting the error message "WARNING hd: no root disk controller found" when running the bootable install cd. I have a raid 5 array with an online spare created using 4 36.3 GB... (2 Replies)
Discussion started by: FrictionBurn
2 Replies

5. SCO

Loading SCO 507 on HP ProLiant ML350 G6

This is my first load of SCO OpenServer v5.0.7 on a HP ProLiant ML350 G6. When it asks me to identify the source media it can't find it no matter how I respond. The SCO compatible page says it used the on board SATA DVD-ROM on Port 2 of the embedded SATA controller with "Legacy IDE emulation (as... (8 Replies)
Discussion started by: farmboy
8 Replies

6. SCO

Change Disk controller in SCO 6.0.0

So today I tried to upgrade a customer from a Proliant with an HPSAS controller to an Intel server with a MEGASAS controller. First, I downloaded the megasas driver from SCO and installed it on the old system. Then I created a new Microlite Edge emergency boot cd with the new driver on it. I... (2 Replies)
Discussion started by: jgt
2 Replies

7. Debian

HP ProLiant DL380 G4 w/ Debian... If your familiar with this machine please help.

Hello, I have a few questions about this server. It has two CPU's 3.20 ghz / 800 mhz / 1MB L2 5120 MB RAM 6 hard disks on HP Smart Array 6i controller (36.4 GB Ultra320 SCSI HD each) RAID set to RAID 5 (5 discs) with one spare (6th disk) USB, 2 Ethernet ports, 1 ILO port, 1 SCSI port ... (2 Replies)
Discussion started by: Marcus Aurelius
2 Replies

8. SCO

Getting error sco unix 507 from cdrom:no controller for device you chosen

Installing SCO UNIX 507 on Dell Poweredge T610. It has no floppy so I downloaded the BTLD onto CD from SCO site to load without floppy drive. BTLD loads ok. when i get to the Media to be used, no matter what option i chose i get the error: No controller for device you have chosen. During bootup you... (9 Replies)
Discussion started by: romanglad112
9 Replies

9. SCO

How to change raid controller driver ? (hardware change)

Hello I'm trying to virtualize an instance of Sco Unix 5.0.5 in VirtualBox (called VM-A) , but sco I have problems set to launch with the new raid controller . The physical machine has a raid controller adaptec (alad driver) but VirtualBox uses buslogic (blc driver) What ... (3 Replies)
Discussion started by: flako
3 Replies

10. SCO

SCO OS 6 Driver for LSIL SAS1064E Raid Controller

Hi all, A client has an SCO OpenServer Server 6.0, that is running on an HP ProLiant Box and they lost the root password. Its equipped with a Doal-Core Intel Pentium Processor. They don't have any media or emergency disk anymore. I tried to boot with the CD Rom, then "Tools", then exit to... (7 Replies)
Discussion started by: thm2222
7 Replies
CCISS(4)						     Linux Programmer's Manual							  CCISS(4)

NAME
cciss - HP Smart Array block driver SYNOPSIS
modprobe cciss [ cciss_allow_hpsa=1 ] DESCRIPTION
cciss is a block driver for older HP Smart Array RAID controllers. Options cciss_allow_hpsa=1: This option prevents the cciss driver from attempting to drive any controllers that the hpsa(4) driver is capable of controlling, which is to say, the cciss driver is restricted by this option to the following controllers: Smart Array 5300 Smart Array 5i Smart Array 532 Smart Array 5312 Smart Array 641 Smart Array 642 Smart Array 6400 Smart Array 6400 EM Smart Array 6i Smart Array P600 Smart Array P400i Smart Array E200i Smart Array E200 Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E500 Supported hardware The cciss driver supports the following Smart Array boards: Smart Array 5300 Smart Array 5i Smart Array 532 Smart Array 5312 Smart Array 641 Smart Array 642 Smart Array 6400 Smart Array 6400 U320 Expansion Module Smart Array 6i Smart Array P600 Smart Array P800 Smart Array E400 Smart Array P400i Smart Array E200 Smart Array E200i Smart Array E500 Smart Array P700m Smart Array P212 Smart Array P410 Smart Array P410i Smart Array P411 Smart Array P812 Smart Array P712m Smart Array P711m Configuration details To configure HP Smart Array controllers, use the HP Array Configuration Utility (either hpacuxe(8) or hpacucli(8)) or the Offline ROM-based Configuration Utility (ORCA) run from the Smart Array's option ROM at boot time. FILES
Device nodes The device naming scheme is as follows: Major numbers: 104 cciss0 105 cciss1 106 cciss2 105 cciss3 108 cciss4 109 cciss5 110 cciss6 111 cciss7 Minor numbers: b7 b6 b5 b4 b3 b2 b1 b0 |----+----| |----+----| | | | +-------- Partition ID (0=wholedev, 1-15 partition) | +-------------------- Logical Volume number The device naming scheme is: /dev/cciss/c0d0 Controller 0, disk 0, whole device /dev/cciss/c0d0p1 Controller 0, disk 0, partition 1 /dev/cciss/c0d0p2 Controller 0, disk 0, partition 2 /dev/cciss/c0d0p3 Controller 0, disk 0, partition 3 /dev/cciss/c1d1 Controller 1, disk 1, whole device /dev/cciss/c1d1p1 Controller 1, disk 1, partition 1 /dev/cciss/c1d1p2 Controller 1, disk 1, partition 2 /dev/cciss/c1d1p3 Controller 1, disk 1, partition 3 Files in /proc The files /proc/driver/cciss/cciss[0-9]+ contain information about the configuration of each controller. For example: $ cd /proc/driver/cciss $ ls -l total 0 -rw-r--r-- 1 root root 0 2010-09-10 10:38 cciss0 -rw-r--r-- 1 root root 0 2010-09-10 10:38 cciss1 -rw-r--r-- 1 root root 0 2010-09-10 10:38 cciss2 $ cat cciss2 cciss2: HP Smart Array P800 Controller Board ID: 0x3223103c Firmware Version: 7.14 IRQ: 16 Logical drives: 1 Current Q depth: 0 Current # commands on controller: 0 Max Q depth since init: 1 Max # commands on controller since init: 2 Max SG entries since init: 32 Sequential access devices: 0 cciss/c2d0: 36.38GB RAID 0 Files in /sys /sys/bus/pci/devices/<dev>/ccissX/cXdY/model Displays the SCSI INQUIRY page 0 model for logical drive Y of controller X. /sys/bus/pci/devices/<dev>/ccissX/cXdY/rev Displays the SCSI INQUIRY page 0 revision for logical drive Y of controller X. /sys/bus/pci/devices/<dev>/ccissX/cXdY/unique_id Displays the SCSI INQUIRY page 83 serial number for logical drive Y of controller X. /sys/bus/pci/devices/<dev>/ccissX/cXdY/vendor Displays the SCSI INQUIRY page 0 vendor for logical drive Y of controller X. /sys/bus/pci/devices/<dev>/ccissX/cXdY/block:cciss!cXdY A symbolic link to /sys/block/cciss!cXdY. /sys/bus/pci/devices/<dev>/ccissX/rescan When this file is written to, the driver rescans the controller to discover any new, removed, or modified logical drives. /sys/bus/pci/devices/<dev>/ccissX/resettable A value of 1 displayed in this file indicates that the "reset_devices=1" kernel parameter (used by kdump) is honored by this con- troller. A value of 0 indicates that the "reset_devices=1" kernel parameter will not be honored. Some models of Smart Array are not able to honor this parameter. /sys/bus/pci/devices/<dev>/ccissX/cXdY/lunid Displays the 8-byte LUN ID used to address logical drive Y of controller X. /sys/bus/pci/devices/<dev>/ccissX/cXdY/raid_level Displays the RAID level of logical drive Y of controller X. /sys/bus/pci/devices/<dev>/ccissX/cXdY/usage_count Displays the usage count (number of opens) of logical drive Y of controller X. SCSI tape drive and medium changer support SCSI sequential access devices and medium changer devices are supported and appropriate device nodes are automatically created (e.g., /dev/st0, /dev/st1, etc.; see st(4) for more details.) You must enable "SCSI tape drive support for Smart Array 5xxx" and "SCSI support" in your kernel configuration to be able to use SCSI tape drives with your Smart Array 5xxx controller. Additionally, note that the driver will not engage the SCSI core at init time. The driver must be directed to dynamically engage the SCSI core via the /proc file-system entry, which the "block" side of the driver creates as /proc/driver/cciss/cciss* at run time. This is because at driver init time, the SCSI core may not yet be initialized (because the driver is a block driver) and attempting to register it with the SCSI core in such a case would cause a hang. This is best done via an initialization script (typically in /etc/init.d, but could vary depending on distribution). For example: for x in /proc/driver/cciss/cciss[0-9]* do echo "engage scsi" > $x done Once the SCSI core is engaged by the driver, it cannot be disengaged (except by unloading the driver, if it happens to be linked as a mod- ule.) Note also that if no sequential access devices or medium changers are detected, the SCSI core will not be engaged by the action of the above script. Hot plug support for SCSI tape drives Hot plugging of SCSI tape drives is supported, with some caveats. The cciss driver must be informed that changes to the SCSI bus have been made. This may be done via the /proc file system. For example: echo "rescan" > /proc/scsi/cciss0/1 This causes the driver to: 1. query the adapter about changes to the physical SCSI buses and/or fibre channel arbitrated loop, and 2. make note of any new or removed sequential access devices or medium changers. The driver will output messages indicating which devices have been added or removed and the controller, bus, target and lun used to address each device. The driver then notifies the SCSI midlayer of these changes. Note that the naming convention of the /proc file-system entries contains a number in addition to the driver name (e.g., "cciss0" instead of just "cciss", which you might expect). Note: Only sequential access devices and medium changers are presented as SCSI devices to the SCSI midlayer by the cciss driver. Specifi- cally, physical SCSI disk drives are not presented to the SCSI midlayer. The only disk devices that are presented to the kernel are logi- cal drives that the array controller constructs from regions on the physical drives. The logical drives are presented to the block layer (not to the SCSI midlayer). It is important for the driver to prevent the kernel from accessing the physical drives directly, since these drives are used by the array controller to construct the logical drives. SCSI error handling for tape drives and medium changers The Linux SCSI midlayer provides an error-handling protocol that is initiated whenever a SCSI command fails to complete within a certain amount of time (which can vary depending on the command). The cciss driver participates in this protocol to some extent. The normal pro- tocol is a four-step process: * First, the device is told to abort the command. * If that doesn't work, the device is reset. * If that doesn't work, the SCSI bus is reset. * If that doesn't work the host bus adapter is reset. The cciss driver is a block driver as well as a SCSI driver and only the tape drives and medium changers are presented to the SCSI midlayer Furthermore, unlike more straightforward SCSI drivers, disk I/O continues through the block side during the SCSI error-recovery process Therefore, the cciss driver implements only the first two of these actions, aborting the command, and resetting the device. Note also that most tape drives will not oblige in aborting commands, and sometimes it appears they will not even obey a reset command, though in most circumstances they will. If the command cannot be aborted and the device cannot be reset, the device will be set offline. In the event that the error-handling code is triggered and a tape drive is successfully reset or the tardy command is successfully aborted, the tape drive may still not allow I/O to continue until some command is issued that positions the tape to a known position. Typically you must rewind the tape (by issuing mt -f /dev/st0 rewind for example) before I/O can proceed again to a tape drive that was reset. SEE ALSO
cciss_vol_status(8), hpsa(4), hpacucli(8), hpacuxe(8), <http://cciss.sf.net>, and Documentation/blockdev/cciss.txt and Documentation/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source tree COLOPHON
This page is part of release 3.53 of the Linux man-pages project. A description of the project, and information about reporting bugs, can be found at http://www.kernel.org/doc/man-pages/. Linux 2012-08-05 CCISS(4)
All times are GMT -4. The time now is 04:10 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy