Hi,
So that potential responders will have an idea of what they're dealing with let me say that while I am a UNIX newbie I have been in IT for over 10 years.
We have several SUN boxes running ver 5 of the OS that have been sitting dormant for some time as they were part of a now defunct... (3 Replies)
Hi,
I will like to allow access to the mysql port (3306) to certain IP address. All other IP's should be automatically blocked. What is the best way to do this? (8 Replies)
I am trying to block ALL traffic except when from ports 9100,22,23 to destination network 192.0.0.0 (my WAN): 2 networks 192.0.3.0 with static route to 192.0.0.0
Shouldn't this work?:
iptables -A INPUT -p tcp -d 192.0.0.0/24 --dport 22 -j ACCEPT
iptables -A INPUT -p tcp -d 192.0.0.0/24... (3 Replies)
i want to kill a tcp connection by killing its pid
with netstat -an i got the tcp ip connection on port 5914
but when i type ps -a or ps-e there is not such process running on port 5914
is it possible that because i do not log on with proper user account i can not see that process running? (30 Replies)
Hi All,
I successfully configured a DEBIAN Lenny bridged firewall
using ebtables.
The bridged interface is br0.
The ethernet interface are eth0 & eth1 respectively.
All the traffic are transparently passing my firewall but i need to find & block temporarily the bandwidth abusers.
Can... (1 Reply)
hi guys
I doing some collocation for a customer, customer requested to use other port for ssh not the default one. OK no problem
and customer will be using rsync to sync backups among other things
I know we have to open port let's say port 5999 for ssh since we are using that one now but I... (1 Reply)
Hi Experts,
I am receiving below error while trying to connect port 8080.
Could not open connection to the host, on port 8080 : connection refused.
iptables configuration
/etc/sysconfig/iptables
# Firewall configuration written by system-config-firewall
# Manual customization of... (1 Reply)
If I would like to know what connection , data , traffic in a network port ( eth0 ) , what can I do ?
ps. because I always found the network is very slow , so I would like what the network port is doing .
Thanks
Login ID ust3 is currently in read-only mode for multiple infractions. Creating... (0 Replies)
Hi Friends,
How to do port forwarding in AIX? We would like to re route traffic from port A to port B on AIX LPAR.
for example: my application is using 8080 port on LPAR and would like to use the 8081 instead of 8080. By default application was configured with 8080. But instead of changing... (2 Replies)
Discussion started by: System Admin 77
2 Replies
LEARN ABOUT DEBIAN
irsend
IRSEND(1) User Commands IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.