OK, everything is fine, however now cannot connect to ASMI through browser,
using both HMC Ports
Default IP 1 = 192.168.2.147
Default IP 2 = 192.168.3.147
I haven't used an IBM p-Series without a HMC for such a long time that i am not sure i can help you off the top of my head here. However, there might be all sorts of problems putting obstacles into the IP-communication between your browser and the Serviceprocessor.
First off, it might be that the IP addresses have once been changed and i am not sure if a simple SP-reset really changes that back to the defaults. (That i am not sure means just that: i don't know. If you have information in the affirmative, then perhaps it is so.)
Second, there is a sure-fire way to connect to the SP, whatever its IP might be: go to the data centre, connect a crossed-out cable to the SP connector 1 or 2 and connect your system directly to it. I have a small netbook for these purposes with a Wireshark/Ethereal software installed, so i can identify even unknown or fogotten IP-adresses. Once you identified the IP-address you still need the ASMI password, which is, btw., completely separate!
I hope this helps.
bakunin