06-19-2018
Do you have support for the M5000? I would say replacing the faulted part should be enough. You can also try to reset the fault and try again to powerup the system. But go slowly with a poweron -d 0 first and see what happens. If domain 0 is running, you can try to start domain 1.
This User Gave Thanks to DukeNuke2 For This Post:
9 More Discussions You Might Find Interesting
1. AIX
Hello:
NOOB here. I attempted to use smit mkcd. Failed on first attempt, not enough space. 2nd attempt tried to place iso on /usr, not enough space there. Cleanup ran for about 5 minutes after aborting. Now AIX won't boot. LCD display on 7029-6E3 says: 0517 MOUNT /USR. Attempted to boot from CD... (11 Replies)
Discussion started by: bbird
11 Replies
2. Solaris
Hi,
I 've a fully loaded M5000 which i would like to partition in 4 domains but i have a concern that since we have only 4 internal disks how can we partition the box in for domains with 2 disks ( mirrored ) in each domain. Should i go ahead with 1 Lun from SAN and 1 internal disk for each of 4... (3 Replies)
Discussion started by: fugitive
3 Replies
3. Solaris
Hi i 've a M5000 running 2 domains in my Lab with following hardconf
SPARC Enterprise M5000; Memory_Size:128 GB;
+-----------------------------------+------------+
| FRU | Quantity |
+-----------------------------------+------------+
| MBU_B... (3 Replies)
Discussion started by: fugitive
3 Replies
4. Solaris
Please advise. Thank you
bash-3.00# cd /usr/sunvts/bin/
bash-3.00# ls
bios.bin iobushangscript.sh stopsunvts vtsprobe
cmos.bin javabridge.jar sunlink vtsreportgenerate
dispatcher loadVtsServer svmVolDiskList vtstalk
env6test... (6 Replies)
Discussion started by: incredible
6 Replies
5. Hardware
I have an M5K with disk issues I'm trying to troubleshoot, and it's causing me some confusion. I know the host has four on-board HDDs, but the format command's output shows c0t0d0, c0t1d0, c3t0d0, and c3t1d0. cfgadm -al shows c0t3d0 as the DVD-ROM drive, and c1 and c2 as SAN disks. Confused yet?
... (2 Replies)
Discussion started by: desertdenizen
2 Replies
6. IP Networking
I took over an M5000 and have a jumper server with a nic to connect to the console IP of an M5000. access via ssh user@ip.
it was working fine, another person can connect remotely on the subnet, but when I ssh,it just hangs and then times out.
so my question is,
any ideas of what I might... (4 Replies)
Discussion started by: rrodgers
4 Replies
7. Solaris
I have an m5000 that Is down.
I have access to XSCF>
and was able to get to the ok prompt.
However, on
>ok boot
it failed to boot.
erred with :
svc.startd: svc:/system/device/fc-fabric:default: Method "/lib/svc/method/fc-fabric" failed due to signal KILL.
Nov 29... (3 Replies)
Discussion started by: goya
3 Replies
8. AIX
A team member installed the wrong version of License Code on a Power 740 system used in our Development environment.
The system will no longer boot.
Does anyone have IBM documentation or experience to share on recovering a system that currently reports "Unsupported License Code version... (1 Reply)
Discussion started by: kevinedailey
1 Replies
9. UNIX for Beginners Questions & Answers
Can anyone offer any advice on how to modify the script below to work on a new system we have, that has no graphics capability? We admin the system through a serial RAS device. I've tried running the below script through the RAS and through an ssh -X session. It failed with something like "GTK... (3 Replies)
Discussion started by: yelirt5
3 Replies
power(9E) Driver Entry Points power(9E)
NAME
power - power a device attached to the system
SYNOPSIS
#include <sys/ddi.h>
#include <sys/sunddi.h>
int prefixpower(dev_info_t *dip, int component, int level);
INTERFACE LEVEL
Solaris DDI specific (Solaris DDI). This entry point is required. If the driver writer does not supply this entry point, the value NULL
must be used in the cb_ops(9S) structure instead.
PARAMETERS
dip Pointer to the device's dev_info structure.
component Component of the driver to be managed.
level Desired component power level.
DESCRIPTION
The power(9E) function is the device-specific Power Management entry point. This function is called when the system wants the driver to set
the power level of component to level.
The level argument is the driver-defined power level to which the component needs to be set. Except for power level 0, which is inter-
preted by the framework to mean "powered off," the interpretation of level is entirely up to the driver.
The component argument is the component of the device to be power-managed. The interpretation of component is entirely up to the driver.
When a requested power transition would cause the device to lose state, the driver must save the state of the device in memory. When a
requested power transition requires state to be restored, the driver must restore that state.
If a requested power transition for one component requires another component to change power state before it can be completed, the driver
must call pm_raise_power(9F) to get the other component changed, and the power(9E) entry point must support being re-entered.
If the system requests an inappropriate power transition for the device (for example, a request to power down a device which has just
become busy), then the power level should not be changed and power should return DDI_FAILURE.
RETURN VALUES
The power() function returns:
DDI_SUCCESS Successfully set the power to the requested level.
DDI_FAILURE Failed to set the power to the requested level.
CONTEXT
The power() function is called from user or kernel context only.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Interface stability |Evolving |
+-----------------------------+-----------------------------+
SEE ALSO
attach(9E), detach(9E), pm_busy_component(9F), pm_idle_component(9F), pm_raise_power(9F), cb_ops(9S)
Writing Device Drivers
Using Power Management
SunOS 5.10 12 Dec 2003 power(9E)