Bond Configuration change not reflected.

I have changed bond configuration(mode) from TLB to ALB in modprobe.conf file.
But after the restart of machine the change is not reflected in the system.While doing a >>cat /sys/class/net/bond0/bonding/mode, it shows TLB mode, where as in modprobe.conf file alb exists.Can somebody help me out to troubleshoot the same?

Last edited by rbatte1; 12-28-2016 at 06:23 AM..
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

I need to change printer configuration

We have several Printers that are pointing to a print server that is now defunct. I need to point these printers to the new print server. I am aware I need to change the configuration in /usr/spool/lp/admins/lp/printers/printername/configuration as well as in /etc/printers.conf. However my... (0 Replies)
Discussion started by: tugger
0 Replies

2. Shell Programming and Scripting

sed to change a configuration file

Hi I want to create a configuration file from a template one. The only thing to change for now is the port number that I need to take from another file that has this format: server:port So I need to take the 2nd field. server is passed in the script argument. how to do that? I... (1 Reply)
Discussion started by: melanie_pfefer
1 Replies

3. Filesystems, Disks and Memory

garbage collection not reflected in the nmon

i have my application running on AIX box (configuration given below) My application does garbage collection pretty well, as such the memory free shows 500 MB - 700 MB freed up in the log statements printed in the application, but the nmon shows the physical space going upwards and does not reflect... (1 Reply)
Discussion started by: mahesh_sivan
1 Replies

4. AIX

Slave NIS server configuration change

Hello Everybody, I have a question regarding SLAVE NIS SERVER in aix. We are using NIS master of Sun Solaris 9.0 which is on different subnet i.e. 10.197.93.0. And Our slave server is having AIX 5.3 installed which is on 10.207.13.0 subnet. I have a query regarding its name and ip address... (0 Replies)
Discussion started by: jit15975
0 Replies

5. UNIX for Advanced & Expert Users

How to bond network interfaces

All, I have a quad NIC on a V880 running Solaris 9. I've heard you can bond interfaces together and get better throughput. I found this link that seems to describe the process well. However, the command mentioned (dladm) is missing. Is there some package I need to install to get this command? Thx.... (2 Replies)
Discussion started by: agcodba
2 Replies

6. Red Hat

Bonding a Bond with LACP

Does anyone know if it's possible to bond two bonds together? My situation is I have two older Cisco switches that cannot carry a LACP (bond level 4) aggregated between them, but separate aggregates can be setup on the switches themselves. In order to have redundancy of two switches I would... (0 Replies)
Discussion started by: christr
0 Replies

7. Emergency UNIX and Linux Support

HP-UX: Help to Change network configuration from APA manual mode (2Gbps) to simple fail over (1Gbps)

Hello HP-UX experts, Server = rx8640 Node partition OS = HP-UX 11.23 arch = IA64 Network switch = Foundry 16 port switch (1Gbps) Existing configuration: Tough to explain as it is very messy (see below for the link of zip of network related fles). 2 x 2Gbps aggregates configured some time... (1 Reply)
Discussion started by: prvnrk
1 Replies

8. Red Hat

How to change bonding configuration in Linux 5.9?

I have 2 ethernet port in my linux (Red hat 5.9) machine.The 2 ethernet ports (eth0 and eth1)are bonded and are making one single ethernet port namely bond0. I have adaptive load share option selected.Now in this condition, if my eth0 port disconnected due to some failure, then will eth1 take the... (0 Replies)
Discussion started by: Anjan Ganguly
0 Replies

9. IP Networking

Centos/Redhat 7 - Team or Bond

Hello my dears, I preparing system running linux. I found that team is advantage than bond with the option "load-balancing for LACP support" and some minor advantages. 8.3. Comparison of Network Teaming to Bonding - Red Hat Customer Portal. But what exactly meaning of this option I don't... (1 Reply)
Discussion started by: tien86
1 Replies
HPSA(4) 						     Linux Programmer's Manual							   HPSA(4)

NAME
hpsa - HP Smart Array SCSI driver SYNOPSIS
modprobe hpsa [ hpsa_allow_any=1 ] DESCRIPTION
hpsa is a SCSI driver for HP Smart Array RAID controllers. Options hpsa_allow_any=1: This option allows the driver to attempt to operate on any HP Smart Array hardware RAID controller, even if it is not explicitly known to the driver. This allows newer hardware to work with older drivers. Typically this is used to allow installation of operating systems from media that predates the RAID controller, though it may also be used to enable hpsa to drive older controllers that would normally be handled by the cciss(4) driver. These older boards have not been tested and are not supported with hpsa, and cciss(4) should still be used for these. Supported hardware The hpsa driver supports the following Smart Array boards: Smart Array P700M Smart Array P212 Smart Array P410 Smart Array P410i Smart Array P411 Smart Array P812 Smart Array P712m Smart Array P711m StorageWorks P1210m Since Linux 4.14, the following Smart Array boards are also supported: Smart Array 5300 Smart Array 5312 Smart Array 532 Smart Array 5i Smart Array 6400 Smart Array 6400 EM Smart Array 641 Smart Array 642 Smart Array 6i Smart Array E200 Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E500 Smart Array P400 Smart Array P400i Smart Array P600 Smart Array P700m Smart Array P800 Configuration details To configure HP Smart Array controllers, use the HP Array Configuration Utility (either hpacuxe(8) or hpacucli(8)) or the Offline ROM-based Configuration Utility (ORCA) run from the Smart Array's option ROM at boot time. FILES
Device nodes Logical drives are accessed via the SCSI disk driver (sd(4)), tape drives via the SCSI tape driver (st(4)), and the RAID controller via the SCSI generic driver (sg(4)), with device nodes named /dev/sd*, /dev/st*, and /dev/sg*, respectively. HPSA-specific host attribute files in /sys /sys/class/scsi_host/host*/rescan This is a write-only attribute. Writing to this attribute will cause the driver to scan for new, changed, or removed devices (e.g., hot-plugged tape drives, or newly configured or deleted logical drives, etc.) and notify the SCSI midlayer of any changes detected. Normally a rescan is triggered automatically by HP's Array Configuration Utility (either the GUI or the command-line variety); thus, for logical drive changes, the user should not normally have to use this attribute. This attribute may be useful when hot plugging devices like tape drives, or entire storage boxes containing preconfigured logical drives. /sys/class/scsi_host/host*/firmware_revision This attribute contains the firmware version of the Smart Array. For example: # cd /sys/class/scsi_host/host4 # cat firmware_revision 7.14 HPSA-specific disk attribute files in /sys /sys/class/scsi_disk/c:b:t:l/device/unique_id This attribute contains a 32 hex-digit unique ID for each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat unique_id 600508B1001044395355323037570F77 /sys/class/scsi_disk/c:b:t:l/device/raid_level This attribute contains the RAID level of each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat raid_level RAID 0 /sys/class/scsi_disk/c:b:t:l/device/lunid This attribute contains the 16 hex-digit (8 byte) LUN ID by which a logical drive or physical device can be addressed. c:b:t:l are the controller, bus, target, and lun of the device. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat lunid 0x0000004000000000 Supported ioctl() operations For compatibility with applications written for the cciss(4) driver, many, but not all of the ioctls supported by the cciss(4) driver are also supported by the hpsa driver. The data structures used by these ioctls are described in the Linux kernel source file include/linux/cciss_ioctl.h. CCISS_DEREGDISK, CCISS_REGNEWDISK, CCISS_REGNEWD These three ioctls all do exactly the same thing, which is to cause the driver to rescan for new devices. This does exactly the same thing as writing to the hpsa-specific host "rescan" attribute. CCISS_GETPCIINFO Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID). CCISS_GETDRIVVER Returns driver version in three bytes encoded as: (major_version << 16) | (minor_version << 8) | (subminor_version) CCISS_PASSTHRU, CCISS_BIG_PASSTHRU Allows "BMIC" and "CISS" commands to be passed through to the Smart Array. These are used extensively by the HP Array Configuration Utility, SNMP storage agents, and so on. See cciss_vol_status at <http://cciss.sf.net> for some examples. SEE ALSO
cciss(4), sd(4), st(4), cciss_vol_status(8), hpacucli(8), hpacuxe(8), <http://cciss.sf.net>, and Documentation/scsi/hpsa.txt and Documentation/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source tree COLOPHON
This page is part of release 4.15 of the Linux man-pages project. A description of the project, information about reporting bugs, and the latest version of this page, can be found at https://www.kernel.org/doc/man-pages/. Linux 2017-09-15 HPSA(4)
All times are GMT -4. The time now is 12:55 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy