Sponsored Content
Special Forums Cybersecurity Can't access my device DJI Phantom 3 which uses UNIX. Need Help please! Post 302949067 by nobr3ga on Tuesday 7th of July 2015 12:50:11 AM
Old 07-07-2015
Can't access my device DJI Phantom 3 which uses UNIX. Need Help please!

Equipment: DJI Phantom 3
I have the root and passwords access, but I cannot find out how to access the equipment.
There is a USB port going to a miniUSB that connects to the equipment, but on Windows is detecting the connection as being a Serial Port (COM3).
I need some help in order to gain access to the file system from my equipment, as with regards to the access itself, I have all data (root & passwords).
Is there anyone that can move forward and try and help me?
Kind regards,

nobr3ga
 

9 More Discussions You Might Find Interesting

1. Linux

Non exclusive sound device access!!

Hi, I was wondering if any of you guys know of way to make applications that use sound device on linux to access it in a "non-exclusive manner", the aim is to be able to use more than one application that requires the sound device. Thanks (0 Replies)
Discussion started by: andryk
0 Replies

2. Linux

attempt to access beyond end of device

Hi, we have running 8 box sles 9 cluster and on an nfs filesystem we have the problem which is grepped from /var/log/messages. Jun 8 13:40:46 qnclpx02 kernel: attempt to access beyond end of device Jun 8 13:40:46 qnclpx02 kernel: sdat: rw=0, want=8894615912, limit=314572800 Is there... (1 Reply)
Discussion started by: ortsvorsteher
1 Replies

3. UNIX for Dummies Questions & Answers

controll access to a device

Hello everyone, I write a program (Linux & Solaris) that will run as non-root user, but the program must have rw access to a device /dev/ipmi (on linux) or /dev/bmc (on solaris). What is the standard way of granting such access? Linux: chmod on /dev/ipmi ? suid root my program? Solaris:... (1 Reply)
Discussion started by: Pavel.Bures
1 Replies

4. Homework & Coursework Questions

The pseudo-device provides a “backdoor” for gaining root access for a particular user.

Problem statement. In this part of the assignment, delegates will create a pseudo-device and write a device driver for it. The pseudo-device provides a “backdoor” for gaining root access for a particular user. Instead of compiling the device driver into the kernel, delegate will create a module.... (1 Reply)
Discussion started by: nyjilgeorge1
1 Replies

5. OS X (Apple)

Not mounted, no-driver USB device in terminal (how to access?)

hi, i am on a quest to access and even mount if possible a drive on os x. there is no driver for the device, but it lists fine in the system profiler. can i access its location from the terminal? how? here is what i get on the system profiler: Speed: Up to 480 Mb/sec Manufacturer: SAMSUNG ... (3 Replies)
Discussion started by: sontarieh
3 Replies

6. UNIX for Advanced & Expert Users

How the user process can access the character device loaded by my module

I am trying to load into the kernel a system-call dynamically (without restarting the kernel and compailing it) in an attempt to (once in kernel mode) write to user process's memory. (I know there is a way to do this with the ptrace interface but it is not an option.) I know the only way to... (1 Reply)
Discussion started by: hopelessProgram
1 Replies

7. UNIX for Advanced & Expert Users

Access a File as a Device?

I backed up my 320GB hard drive to a file with dd: dd if=/dev/sda of=dev_sda.17-Mar-2012 bs=1048576The main idea was to be able to be able to completely replace my hard drive from this backup if necessary, but I'd also like to be able to restore individual files. I realize I could use this dd... (20 Replies)
Discussion started by: Matt Miller
20 Replies

8. Ubuntu

Cannot access or boot encrypted drive (gave up waiting for root device...)

I cannot access or boot from my C drive. I'm running Zorin 9 and the drive is a Samsung SSD. The disk was encrypted on install, and that has not given me any problems before. When I start the system it gets to the memory test page, and does not then load the password prompt, which it used to.... (1 Reply)
Discussion started by: David4321
1 Replies

9. UNIX for Dummies Questions & Answers

Exclusive access for few IPs to NTP device

How to provide a client exclusive access to the NTP device or NTP server. Example: 1. Configured md5 authentication for a subnet added below restriction line to the subnet as below in ntp.conf file. Also configured the keys and md5 authentication working . restrict 192.168.1.0 mask... (1 Reply)
Discussion started by: iqtan
1 Replies
sane-microtek2(5)					   SANE Scanner Access Now Easy 					 sane-microtek2(5)

NAME
sane-microtek2 - SANE backend for Microtek scanners with SCSI-2 command set DESCRIPTION
The sane-microtek2 library implements a SANE (Scanner Access Now Easy) backend that provides access to Microtek scanners with a SCSI-2 com- mand set. This backend can be considered alpha to beta. Some scanner models are reported to work well, others not. New development ver- sions of this backend can be obtained from http://karstenfestag.gmxhome.de There exists a different backend for Microtek scanners with SCSI-1 command set. Refer to sane-microtek(5) for details. And there is work in progress for the ScanMaker 3600. See http://sourceforge.net/projects/sm3600 At present, the following scanners are known positively to work with this backend: Vendor Product id Remark -------------------------------------------------------------------- Microtek E3+ Parport and SCSI Microtek X6 SCSI Microtek X6EL SCSI Microtek X6USB USB Microtek ScanMaker V300 Parport and SCSI Microtek ScanMaker V310 Parport and SCSI Microtek ScanMaker V600 Parport and SCSI Microtek ScanMaker 330 SCSI Microtek ScanMaker 630 SCSI Microtek ScanMaker 636 SCSI Microtek ScanMaker 9600XL SCSI; only flatbed mode? Microtek Phantom 330CX Parport Microtek SlimScan C3 Parport Microtek SlimScan C6 USB Microtek Phantom 636 SCSI Microtek Phantom 636CX Parport Microtek V6USL SCSI and USB Microtek V6UPL USB; not stable Microtek X12USL SCSI; only 8bit color, work in progress Vobis HighScan SCSI (E3+ based models) Scanport SQ300 Parport? Scanport SQ4836 SCSI Scanpaq SQ2030 Parport Additional information can be found at http://www.sane-project.org/. If you own a Microtek scanner other than the ones listed above, it may or may not work with SANE! Because equal scanners are sold under different names in different countries your model may be equivalent to one of the above. The parport scanners work with the ppscsi + onscsi kernel modules. See http://cyberelk.net/tim/parport/ppscsi.html and http://penguin- breeder.org/kernel/download/. The USB scanners work with the microtek kernel module. You may have to add the vendor and model codes to microtek.c if they aren't yet listed there. Both parport and USB scanners need the generic SCSI support, so check if you have loaded the scsi_mod and sg modules! If you try your scanner for the first time keep an eye on it. If it gets commands that it doesn't understand the scanhead may go beyond the scan area. The scanner then makes strange noises. In this case immediately switch off the scanner or disconnect its power cable to prevent damages! If your scanner is a different one than the models mentioned above and it is working please tell the author about it. It would be nice if you add a logfile to this information (creation of the logfile: see below). If your scanner is not working properly you also should create a logfile and send it to the author. He will use the information to improve the backend and possibly make your scanner work. How to create the logfile? - put the line "option dump 2" into your microtek2.conf file or change the existing "option dump" to "2" - in a terminal (bash) type "export SANE_DEBUG_MICROTEK2=30" and then "scanimage -l0 -t0 -x100 -y20 2>scan.log >sout.pnm" You get two files: scan.log contains the logfile and sout.pnm the scanned image (if there was scanned something). Zip them before sending. FRONTEND OPTIONS
This backend dynamically enables the options for the frontend, that are supported by the scanner in dependence of the scanning-mode and other options. Not supported options are disabled. The following options are supported by the Microtek2-driver: Color, grayscale, halftone and lineart scans. Highlight, midtone, shadow, contrast, brightness, exposure time control, gamma correction, threshold (dependent of the scan mode and the scanner capabilities) Transparency media adapter, automatic document feeder Additional options can be enabled or disabled in the microtek2.conf file. See the configuration section of this manpage. DEVICE NAMES
This backend expects device names of the form: special Where special is the UNIX path-name for the special device that corresponds to the scanner. The special device name must be a generic SCSI device or a symlink to such a device. Under Linux, such a device name could be /dev/sga or /dev/sge for example. CONFIGURATION
The configuration file for this backend resides in /etc/sane.d/microtek2.conf. Its contents is a list of device names that correspond to Microtek scanners with SCSI-2 interface. Empty lines and lines starting with a hash mark (#) are ignored. The configuration file may also contain options. Global options that are valid for all devices are placed above the device names. Device- specific options are placed under the device name. Note that, except for option dump <n> and option strip-height <n>, the entry in the microtek2.conf file only enables the corresponding option for being showed in the frontend. There, in the frontend, you can switch the options on and off. Currently the following options are supported: option dump <n> option strip-height <n> option no-backtrack-option <on/off> option lightlid-35 <on/off> option toggle-lamp <on/off> option lineart-autoadjust <on/off> option backend-calibration <on/off> option colorbalance-adjust <on/off> option dump <n> enables printing of additional information about the SCSI commands that are sent to the scanner to stderr. This option is primarily useful for debugging purpose. This option has to be a global option and is best placed at the top of the microtek2.conf file. If n=1 the contents of the command blocks and the results for the INQUIRY and READ SCANNER ATTRIBUTES command are printed to stderr. If n=2 the contents of the command blocks for all other SCSI commands are printed to stderr, too. If n=3 the contents of the gamma table is printed, too. If n=4 all scan data is additionally printed to stderr. The default is n=1. option strip-height <n> , where <n> is a floating point number, limits the amount of data that is read from the scanner with one read com- mand. The unit is inch and <n> defaults to 1.0, if this option is not set in the configuration file. If less than <n> inch of data fit into the SCSI buffer, then the smaller value is used and this option has no effect. If your system has a big SCSI buffer and you want to make use of the whole buffer, increase the value for <n>. For example, if <n> is set to 14.0, no restrictions apply for scanners with a letter, legal or A4 sized scan area. The following options enable or disable additional frontend options. If an option is set to <on> an appropriate option will appear in the frontend. option no-backtrack-option <on/off> prevents the scanner head from moving backwards between the read commands. This speeds up scanning. Try it. option lightlid-35 <on/off> If you use the LightLid-35 transparency adapter you get an advanced option which switches off the flatbed lamp during the scan. option toggle-lamp <on/off> You get a button in the frontend where you can switch on and off the flatbed lamp. option lineart-autoadjust <on/off> You can tell the backend to try to determine a good value for the lineart threshold. option backend-calibration <on/off> Some scanners (e.g. Phantom 330CX and 636CX) need to have calibrated the data by the backend. Try this option if you see vertical stripes in your pictures. option colorbalance-adjust <on/off> Some scanners (e.g. Phantom 330CX and 636CX) need to have corrected the color balance. If this option is enabled you get advanced options where you can balance the colors. And you will have a button to use the values that the firmware of the scanner provides. A sample configuration file is shown below: option dump 1 option strip-height 1.0 /dev/scanner option no-backtrack-option on # this is a comment /dev/sge option lightlid-35 on This backend also supports the new configuration file format which makes it easier to detect scanners under Linux. If you have only one scanner it would be best to use the following configuration file for this backend: option dump 1 option strip-height 14.0 option no-backtrack-option on option backend-calibration on option lightlid-35 on option toggle-lamp on option lineart-autoadjust on option colorbalance-adjust off scsi * * Scanner In this case all SCSI-Scanners should be detected automatically because of the scsi * * Scanner line. FILES
/etc/sane.d/microtek2.conf The backend configuration file. /usr/lib64/sane/libsane-microtek2.a The static library implementing this backend. /usr/lib64/sane/libsane-microtek2.so The shared library implementing this backend (present on systems that support dynamic loading). ENVIRONMENT
SANE_DEBUG_MICROTEK2 If the library was compiled with debug support enabled, this environment variable controls the debug level for this backend. E.g., a value of 255 requests all debug output to be printed. Smaller levels reduce verbosity. To see error messages on stderr set SANE_DEBUG_MICROTEK2 to 1 (Remark: The whole debugging levels should be better revised). E.g. just say: export SANE_DEBUG_MICROTEK2=128 SEE ALSO
sane-scsi(5), sane(7) AUTHORS
Bernd Schroeder (not active anymore) Karsten Festag karsten.festag@gmx.de 13 Jul 2008 sane-microtek2(5)
All times are GMT -4. The time now is 11:48 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy