01-11-2015
Your raidctl output at the end of your post says that, as you already know, you have two hardware raid1 mirrored drives. The disk/raid controller is presenting this pair of drives as one disk to the O/S. Control, writing and maintenance of this mirror lies solely with the hardware raid controller. The O/S thinks that it is talking to a single disk.
There is no issue if you carry out normal O/S patching on the system. Usual precautions with regards backup/recovery.
If you think this should be an abnormal process due to the presence of the hardware raid1 controller please describe why you think that.
---------- Post updated at 04:57 PM ---------- Previous update was at 04:48 PM ----------
I think that you might be being put off by the fact that the LSI hardware raid controller is integrated into the T5220.
If you had fitted an add-in raid controller card and through it's management console mirrored two disks and presented them to the host as one drive (so the host is unaware of the mirror), then the raid controller is just a SCSI controller as far as the host hardware is concerned.
What you have there is no different apart from the raid controller has been integrated by Sun (Oracle) into the hardware.
9 More Discussions You Might Find Interesting
1. Solaris
I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies
2. Solaris
Hi,
I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1"
The System did come preinstalled as it comes from sun. I did not do much on it.
I booted system using boot cdrom -s
gave format... (6 Replies)
Discussion started by: upengan78
6 Replies
3. Solaris
Hi,
I have a root with hardware RAID on c0t0d0 and c0t2d0. I would like to set the boot device sequence in OBP for both hdds.
I have checked in ls -l /dev/rdsk/ for the path of c0t2d0 but it does not exist. Can anyone shed some lights on this?
AVAILABLE DISK SELECTIONS:
0.... (12 Replies)
Discussion started by: honmin
12 Replies
4. UNIX for Dummies Questions & Answers
Hi
Can someone tell me what are the differences between software and hardware raid ?
thx for help. (2 Replies)
Discussion started by: presul
2 Replies
5. Solaris
Hi,
I have a question. Do LiveUpgrade supports hardware raid?
How to choose the configuration of the system disk for Solaris 10 SPARC?
1st Hardware RAID-1 and UFS
2nd Hardware RAID-1 and ZFS
3rd SVM - UFS and RAID1
4th Software RAID-1 and ZFS
I care about this in the future to take... (1 Reply)
Discussion started by: bieszczaders
1 Replies
6. Hardware
Hi all
I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS.
The documentation doesn't make it clear if:
1. The... (6 Replies)
Discussion started by: soliberus
6 Replies
7. Solaris
Server Model: T5120 with 146G x4 disks.
OS: Solaris 10 - installed on c1t0d0.
Plan to use software raid (veritas volume mgr) on c1t2d0 disk.
After format and label the disk, still not able to detect using vxdiskadm.
Question:
Should I remove the hardware raid on c1t2d0 first?
My... (4 Replies)
Discussion started by: KhawHL
4 Replies
8. Solaris
Dear All ,
We need to do patching on one Solaris Server , where we have raid 0 configured.
What is the process to patch a Server if RAID 0 (Concat/Stripe) is there.
Below is the sample output.
# metadb
flags first blk block count
a m pc luo 16 ... (1 Reply)
Discussion started by: jegaraman
1 Replies
9. Solaris
Dear All ,
Pl find the below command ,
# raidctl -l
Controller: 1
Volume:c1t0d0
Disk: 0.0.0
Disk: 0.1.0
Disk: 0.3.0
#
raidctl -l c1t0d0
Volume Size Stripe Status Cache RAID
Sub Size ... (10 Replies)
Discussion started by: jegaraman
10 Replies
LEARN ABOUT HPUX
vparutil
vparutil(1M) vparutil(1M)
NAME
vparutil - get and set SCSI parameters for SCSI controllers from a virtual partition
SYNOPSIS
dev_path
dev_path
dev_path scsi_id] scsi_rate]
DESCRIPTION
The command gets and sets SCSI parameters for SCSI controllers within a running virtual partition. When setting the SCSI parameters using
the option, the virtual partition which owns the specified SCSI controller must be in the down state. If not, the command will fail with
the appropriate error code.
The SCSI parameters for a given SCSI controller must first be set (from the firmware BCH prompt or using the option) before the parameters
can be retrieved using the option.
The command is allowed on Itanium(R)-based platforms for compatibility. No action is taken for the command.
Options
recognizes the following command-line options:
Deletes an entry for the specified SCSI controller at
dev_path from the SCSI table.
Gets the SCSI parameters for the specified SCSI controller at
dev_path.
Sets the SCSI parameters for the specified SCSI controller at
dev_path.
Operands
recognizes the following command-line operands:
dev_path The device path of the SCSI controller.
id The SCSI ID for the specified controller (defaults to 7).
rate The SCSI rate for the specified controller. This parameter can have one of two values: for the corresponding fast wide and
ultra wide SCSI interfaces.
Note
For managing SCSI controllers, use corresponding SCSI utilities. For further information refer to
SECURITY RESTRICTIONS
This command is restricted to processes owned by superuser.
When virtual partition flexible administrative capability is enabled, only a Designated-Admin vPar can set SCSI parameters for SCSI con-
trollers.
EXAMPLES
Set the SCSI ID for controller at 0/0/2/0 to 3 with the fast wide rate:
RETURN VALUE
Successful.
Invalid SCSI controller specification.
Invalid SCSI ID.
Could not communicate with virtual partition monitor.
Virtual partition which owns SCSI controller is not in down state.
Internal firmware call failed.
Other error.
AUTHOR
was developed by the Hewlett-Packard Company.
SEE ALSO
vparadmin(1M), vparboot(1M), vparcreate(1M), vparconfig(1M), vpardump(1M), vparefiutil(1M), vparenv(1M), vparextract(1M), vparmodify(1M),
vparreloc(1M), vparremove(1M), vparreset(1M), vparstatus(1M), vparresources(5), vpartition(5), vpmon(5).